18
FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 1

FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

Embed Size (px)

Citation preview

Page 1: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

FPCCD VTX Overview

Yasuhiro SugimotoKEK

2012/12/20@JSPS Tokubetsu-Suisin annual meeting

11

Page 2: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

Outline

• FPCCD VTX for ILD

• FPCCD sensor R&D

• CO2 cooling for VTX

• FY2013 plan

2

Page 3: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

Vertex detector for ILD• Structure

– Barrel part only: |z|=62.5/125 mm– Double-sided layer x3– R=16~60mm– |cos|<0.97

• Minimization of material budget of ladders is a big challenge– 0.3%X0/ladder = 0.15%X0/layer

3

Page 4: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

FPCCD VTX for ILD

• Pixel size– 5um for inner two layers– 10um for outer four layers (previously 5um)

• Power consumption– ~40W for on-chip amp and ASICs inside cryostat– ~400W for clock drivers and data processing circuits

outside the cryostat– ~?? W for the aluminum gate line on CCD

4

Pixel size (in)

Pixel size (out)

# of ch /chip (in)

# of ch /chip (out)

# of ch (total)

Power consumption

Old design 5 um 5 um 28 56 7392 111 W

New design 5 um 10 um 15 15 2280 34 W

Page 5: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

FPCCD sensor R&DFY Sensor

2004 Fully depleted CCD, 24um pixel

2005 Fully depleted CCD, 24um pixel

2006 Fully depleted CCD, 24um pixel

2007 1st FPCCD: small size (6mm2),12um pixel

2008 2nd FPCCD: small size, 12um pixel (modified output amp)

2009 3rd FPCCD: small size, 12, 9.6, 8, 6um pixel

2010 4th FPCCD: small size, 12, 9.6, 8, 6um pixel (modified process)

Thin wafer:50um

2011 Small size, 12, 9.6, 8, 6um pixel (modified process), thin wafer

2012 Small size, 6um pixel, 4ch, different H-register size

Large size (12x64mm2), 6,8,12um pixel, 8ch

Small size, 6um pixel, thin wafer (for beam test)

2013 Small size, 5um pixel ?

Large size, thin wafer ?5

Page 6: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

FPCCD sensors

6

Page 7: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

R&D goal

• FPCCD sensors– Pixel size; 6um– Chip size;1cmx6.5cm– Speed >10Mpix/s– F.W.C. > 10000 e(?)– Power <10mW/ch– Rad. Tolerance >1x1013e/cm2

(=1x1012/cm2/y x 3y x safety factor 3)

• Readout ASIC– Speed > 10Mpix/s– Power < 6mW/ch– Noise < 30 electrons

• Peripheral circuit– Clock driver– Data suppression– Etc.

• Engineering R&D– Over-all design– Low-mass ladder– Cooling system (~-40℃)– Support structure Engineering prototype

7

5um (?)

Page 8: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

R&D status

• 6um pixel works if horizontal register is 6x12um2 or larger

• Full-well capacity (~5000e) is still to be improved (>10000e)

• Large prototype works!• Beautiful Fe55 X-ray spectrum

is obtained using an FPCCD of 12um pixel at 2.5Mpix/s speed

• Test of FPCCDs of 6um pixels using new readout electronics (new CCD board with new FE ASIC (AFFROC-1)+ SEABAS2-board) on going

8

Page 9: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

CO2 cooling system• FPCCD will be operated at low temperature (-40 degree) to

minimize CTI• Power consumption ~40W inside the cryostat• Cooling with cold air (nitrogen) flow would not be enough• Cooling system using 2-phase CO2 is a very attractive

alternative because of its large cooling capacity (~300J/g)• Cooling tube is attached to VTX end-plate and heat produced

by CCD output amp and ASIC is removed by conduction through CFRP ladder (simulation study for thermal design is necessary)

• Material budget increase is small: 0.3%X0 for end-plate and 0.1%X0 for the cryostat

• Return line of CO2 will be used to cool the electronics outside the cryostat (~200W/side)

• Inner support tube should be air-tight and filled with dry air/nitrogen in order to prevent condensation on the CO2 tube

9

Page 10: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

Common engineering design

• Cooling pipe + Support shell

10

Page 11: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

CO2 cooling system

• CO2 collaboration in Japan– ILC VTX, ILC TPC, Belle-II VTX, and KEK cryogenic group– We constructed “blow system” and temperature was

successfully controlled between -40 and +15 degrees

Heater

Needle valve

Back pressureregulator

Detector

CO2 bottle

Heatexchanger

11

Page 12: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

CO2 cooling system

12

Page 13: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

CO2 cooling system• R&D of circulating system using a compressor: Supported by

KAKENHI(C) and KEK Detector Technology Project– Design completed– Components are ordered– Assembly by the end of FY2012

13

T

T

F2V5

F4

Chiller5~20℃

J4

J3

V3

D

駆動用エアコンプレッサーPa <0.8 MPa,~400L/min

CO2(ヒーター付レギュレータ使用)

1/4"または接触(温度センサ)3/8"1/2"電気配線

P

T

24V

P24V

T

P

24V

DI3 24V DMAC100V

RU24V

T

P 24V

TT

P

T

P24V DI1

DI224V

T

TCDC

AC100V

AC100V

P24V

GB

Buffer1

Buffer2

J1

J2

J5

J6

J8 J9 J7

Vacuum Vent Vent

V1

V2

V4

V6

V7

V8

V9

V10

V11

RV1RV2

RV3

RV4

RV5

M1

M2

DI424V

DI524V

M4CV

P1

P2

P3

P4

P5

P6P7

F1

Heat bath

M3F3

HEX

2012/12/5

DC24VAC100V

DataLogger

20ch

Page 14: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

FY2013 plan• Beam test

– Demonstrate spatial resolution– Test beam at JPARC (1GeV)

• Neutron damage test– Few tens of MeV/c neutron beam is available at CYRIC

cyclotron in Tohoku University– FPCCD neutron damage test in FY2013~2014

• FPCCD Prototypes– Large thin wafer (?)– Small 5um pixel chip (?)

• 2nd AFFROC prototype, if necessary• Bare chip test

– Fabricate a test board for bare chips before ladder R&D

14

Page 15: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

Backup slides

15

Page 16: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

Beryllium support shell• FEA calculation of

deformation– 1kgf is applied in

z-direction– Maximum

deformation is less than 2m

– Total weight is less than 500g max force caused by the friction at the kinematic mount would be less than 500gf

(mm)16

Page 17: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

Ladder

• Structure

Layer-1 Layer-2,317

Page 18: FPCCD VTX Overview Yasuhiro Sugimoto KEK 2012/12/20 @JSPS Tokubetsu-Suisin annual meeting 11

Cooling system• Cooling tube

• Titanium tube 2mm o.d. and 1.5mm i.d. is attached to the VTX endplate near the endplate annuli

• The return line of the cooling tube is also used for the cooling of the junction box

• 4 tubes/side run along the beam pipe between the vertex detector and the end of the inner support tube

18