3
McHale Project: 15019.0 ISTROENERGO Performance Test Procedure – CTG Performance Rev. 5 McHale & Associates, Inc. APPENDIX C Instrument List 39 of 63

Instrument List for Rev6

Embed Size (px)

DESCRIPTION

instrument list

Citation preview

Page 1: Instrument List for Rev6

McHale Project: 15019.0 ISTROENERGO Performance Test Procedure – CTG Performance Rev. 5

McHale & Associates, Inc.

APPENDIX C

Instrument List

39 of 63

Page 2: Instrument List for Rev6

McHale Project: 15019.0 ISTROENERGO Performance Test Procedure – CTG Performance Rev. 5

McHale & Associates, Inc.

Measurement Instrument Accuracy

Station / Temporary

Primary / Secondary

Quantity Plant ID / KKS

Net Electrical Output, PNet

CT-0.2% PT-0.2%

Meter – 0.08% Unc – 0.29%

CT-Station PT-Station

Meter-Temporary Primary

CT’s – 3 per CTG PT’s – 3 per CTG Meter – 1 per CTG

01BAT10CE010-T11, -T21, -T31 01BAT10CE100-T11, -T21, -T31 02BAT10CE010-T11, -T21, -T31 02BAT10CE100-T11, -T21, -T31

Generator Power Factor, PF

CT-0.5% PT-0.2%

Meter-0.08% Unc-0.54%

CT-Station PT-Station

Meter-Temporary Primary

CT’s – 3 per CTG PT’s – 3 per CTG Meter – 1 per CTG

Unit 1: GCT4, 01VT Unit 2: GCT4, GPT

System Voltage, HV 0.2%

PT-Station Meter-Temporary

Primary PT’s – 3 per CTG Meter – 1 per CTG

01BAT10CE010-T11, -T21, -T31 02BAT10CE010-T11, -T21, -T31

Generator Voltage, LV 0.2%

PT-Station Meter-Temporary

Primary PT’s – 3 per CTG Meter – 1 per CTG

Unit 1: 01VT Unit 2: GPT

System Frequency, HZ 0..08%

PT-Station Meter-Temporary

Primary PT’s – 3 per CTG Meter – 1 per CTG

01BAT10CE010-T11, -T21, -T31 02BAT10CE010-T11, -T21, -T31

Ambient Temperature, Tamb

0.14C Temporary Primary 8 per CTG Inside Gas Turbine Filter House. Upstream of filters.

Barometric Pressure, Pamb

0.065% Temporary Primary 2 per CTG Gas Turbine Centerline. Outside of enclosure.

Wet Bulb Temperature, Twb

0.14C Temporary Primary 4 per CTG Inside Gas Turbine Filter House. Upstream of filters.

Gas Fuel Temperature at Site Boundary, TNG

0.14C Temporary Primary 2 TI-00EKG10 CT520 TI-00EKG20 CT520

Gas Fuel Pressure at Site Boundary, PNG

0.065% Temporary Primary 2 PI-00EKG20 CP520 PI-00EKG10 CP520

Gas Fuel Flow, MNG, MPres, MTemp

Meter – 0.2% Pres – 0.065% Temp – 0.14C Unc – 0.35%

Meter - Station Pres – Temporary

Temp - Station Primary

Meter – 2 Pres – 2

Temp – 2

Meter – FIR-00EKG10 CF030 Pres – PIR-00EKG10 CP030 Temp – TIR-00EKG10 CT030 Meter – FIR-00EKG20 CF030 Pres – PIR-00EKG20 CP030 Temp – TIR-00EKG20 CT030

Fuel Oil Flow, MLF 0.2% Station Primary 1 FT6247

40 of 63

kurucja
Typewritten Text
kurucja
Typewritten Text
TIR 00EKA10 CT010 TIR 00EKA10 CT040
kurucja
Line
kurucja
Line
kurucja
Line
kurucja
Typewritten Text
PIR 00EKA10 CP010 PIR 00EKA10 CP040
kurucja
Line
kurucja
Typewritten Text
FIR 00EKA10 CF020
kurucja
Typewritten Text
FIR 00EKA10 CF050
kurucja
Line
kurucja
Line
kurucja
Typewritten Text
???
kurucja
Typewritten Text
???
kurucja
Typewritten Text
???
kurucja
Typewritten Text
???
Page 3: Instrument List for Rev6

McHale Project: 15019.0 ISTROENERGO Performance Test Procedure – CTG Performance Rev. 5

McHale & Associates, Inc.

Fuel Analysis, LHVNG, LHVLF

N/A Temporary Primary N/A Laboratory Analysis of Gas and Liquid Fuel Samples

Chilled Water Flow, MCW 0.5% Station Primary 1

01 PGA10 CF001 02 PGA10 CF001

Chilled Water Supply Temperature, CCW

0.14C Station Primary 1 TT306

Chilled Water Return Temperature, HCW 0.14C Station Primary 1

01 PGA20 CT001 02 PGA20 CT001

HP Turbine Speed N/A Station Secondary 1 per CTG SE6800/SE6801

LP Turbine Speed N/A Station Secondary 1 per CTG SE6812/SE6813 PS3-CDP N/A Station Secondary 1 per CTG PT6804/PT6814 P3-HP Compressor Inlet Pressure

N/A Station Secondary 1 per CTG PT6859A/PT6859B

T3CRF – CDT N/A Station Secondary 1 per CTG TE6838A/TE6838B T48

N/A Station Secondary 1 per CTG TE6843/TE6844/TE6845/TE6846/TE6847/TE6848/TE6849/TE6850 / T48SEL

WAR36 – Combuster Water to Air Ratio

N/A Station Secondary 1 per CTG FE-6243

T25INF – HPC Inlet Temp

N/A Station Secondary 1 per CTG TE6837A/TE6837B

T2 – LP Compressor Inlet Temp

N/A Station Secondary 1 per CTG TE6821A/TE6821B

Note: Station instruments will be recorded by the facility DCS Historian. Temporary instruments will be recorded by the temporary McHale Data Acquisition System. See section 2.5 for details.

41 of 63