Armin Reichold. David Urner. Paul Coe. Matthew Warden. MONALISA at CLIC. Mon itoring , Ali gnment & S tabilisation with high A ccuracy. MONALISA. Is an interferometric metrology system for continuous monitoring of position critical accelerator components - PowerPoint PPT Presentation
Citation preview
MONALISAat CLIC
David Urner
Paul Coe
MatthewWarden
Armin Reichold
Monitoring, Alignment & Stabilisation with high Accuracy
18. 3. 08 D. Urner 2
MONALISA
• Is an interferometric metrology system for continuous monitoring of position critical accelerator components
• Consists of a fixed network of evacuated interferometric distance meters
18. 3. 08 D. Urner 3
Concepts
18. 3. 08 D. Urner 4
Compact Straightness Monitor
• 6D position transferred from left to right– breaking of symmetries is important
• Preliminary simulation results of CSM Resolution: – y:10nm – distance meter resolution: 1nm = Resolution in z-direction– Positional change of optics components with respect to each other: 1nm. That’s the challenge!
10cm
18. 3. 08 D. Urner 5
Measurement lines
We measure distances along measurement lines using two techniques:•Absolute distance interferometry <m resolutions•Displacement interferometry nm resolutions
Each line is the same, and is capable of performing both types of measurement.
Absolute distanceDisplacement
18. 3. 08 D. Urner 6
Interferometer operation
Intensity
18. 3. 08 D. Urner 7
Interferometer operation
Phase = 2π (Optical Path Distance) / Wavelength
Φ = 2π D / λ = 2π D (ν / c)
D = (c/ 2π) (ΔΦ/Δnu)
R = (c/ 2π) (Δθ/Δnu)D = R (ΔΦ/Δθ)
ΔD = (c/2π ν) ΔΦ
Fixed Frequency Interferometry
Frequency Scanning Interferometry
frequeny scanning
18. 3. 08 D. Urner 8
Distance meter
• Measurement Frequencies:– FFI: up to 10kHz– FSI: up to 1Hz
• Long term stability determines low frequency behaviour– Minutes possible– Lot of work needed to extend to hours or days.
• Advantage of interferometric measurement system is fairly low cost per line.– Use of telecom frequency allows use of cheap commercial
hardware– Cheap amplification of light– Current estimate: as low as £800 per distance metre
18. 3. 08 D. Urner 9
Current Status
18. 3. 08 D. Urner 10
Fixed Frequency Interferometry
0 200 4000.2
0.4
0.6
0.8
1.0
Ph
oto
dio
de
sig
na
l / a
.u.
time / ms
0 200 400
-4
-2
0
Dis
pla
cem
en
t / m
Time / ms
Measurement over 400mm distance
18. 3. 08 D. Urner 11
Frequency Scanning Interferometry
Measurement over 400mm distance
=750nm=70nm
Add box to reduce air turbulence
18. 3. 08 D. Urner 12
Fixed Frequency Interferometry
• Must reach low level of uncertainty for:– Laser frequency– Refractive index
18. 3. 08 D. Urner 13
Vacuum System
8 way fibre ribbon
Tapered hole
Vacuum vessel wall
18. 3. 08 D. Urner 14
Frequency Stabilisation• Lock laser to spectral feature of rubidium• Use a frequency doubling crystal to reach this
frequency
18. 3. 08 D. Urner 15
Operation at KEK
ATF2 Final focus region
Shintake Monitor
Final Focus Quadrupole
18. 3. 08 D. Urner 16
Summary
• Current status– 5nm FFI resolution (at 400mm distance)– 70nm FSI resolution (at 400mm distance)
• Future– Reduce uncertainties with vacuum and laser
stabilisation for FFI and dual laser scanning for FSI– Test a full system in an accelerator environment at
KEK– Monitor beam-line element at CTF3– Improve resolution to sub-nanometer scale