Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
PAEDIATRICS
PAEDIATRICS
2
EX P ERT I SE I N C R I T I C A L C A RE
Editorial
For over 35 years, we have been focusing our research on doctor’s needs and have designed in France innovating devices meeting the most stringent criteria.
We work in close collaboration with the finest specialists in the industry to provide the solutions best suited to the management of patients.
We are proud of our certificates guaranteeing the excellence of our products, based on the use of selected raw materials and products complying with optimised and validated manufacturing procedures.
Prodimed is ISO 9001 and ISO 13485 certified.
Our devices are manufactured in France.See our latest news on
www.prodimed.com www.plastimed.fr
Plastimed®, Ombilicath®, Seldiflex®, Seldicath®, Hasselcath®, Pleurocath®, Combicath®, Desil-intro®, Microdard® are registered trademarks of Prodimed SAS.
EDITORIAL
PAEDIATRICS
3
EX P ERT I SE I N C R I T I C A L C A RE
Table of Contents Paediatrics
P.04 Meaning of pictograms
P.05 Chapter 1 I UMBILICAL
P.08 Chapter 2 I CENTRAL VENOUS
P.09 Central venous catheters (Seldinger technique)
P.14 Central venous catheters for tunnelisation (Seldinger technique)
P.19 Chapter 3 I ARTERIAL (SELDINGER TECHNIQUE)
P.19 Chapter 4 I RESPIRATORY TRACT
P.20 Pleural drainage
P.38 Bronchial sampling
P.25 Chapter 5 I ACCESSORIES
P.26 Introducers and needles
P.30 Infusion filters
P.31 Repair kits
P.32 Hubs and caps
P.33 Other accessories
P.34 Measuring unit conversion tables
P.35 Index of references
TABLE OF CONTENTS
PAEDIATRICS
4
EX P ERT I SE I N C R I T I C A L C A RE
Meaning of pictograms
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
2
Blister pack
Peel pack
Traceability labels
Double pack
Radio-opaque
Latex free
Single use
Polyurethane
Polyvinyl chloride
Polytetrafluoroethylene
Fluorinated ethylene-propylene
Polyethylene
BLUE – DISTAL
YELLOW – PROXIMAL
GREEN – MEDIAL 1
WHITE – MEDIAL 2
All products of the Plastimed range are phthalate-free.
For further information on the indications, contraindications and precautions, please refer to the specific instructions for use supplied with the products.
GLOSSARY
Conditioning Technical security
Color codes for multi-lumen models:
Manufacturing Materials
Chapter 1 UMBILICAL
5
EX P ERT I SE I N C R I T I C A L C A RE
Easy and fast vascular access during the first 72 hours of life in neonates used for:
• Infusions• Blood volume expansion• Central venous pressure monitoring• Parenteral nutrition • Blood sampling
PAEDIATRICS
6
EX P ERT I SE I N C R I T I C A L C A RE
Chap. 1 I UMBILICAL
SINGLE LUMEN OMBILICATH®
SINGLE LUMEN OMBILICATH®OPEN TIP
UMBILICAL ARTERY OR VEIN REFERENCE
CATH LENGTH
Fr (mm) GAUGE cm
3.5 (1.2) 18G 1183.12 30
5 (1.7) 16G 1183.17 30
7 (2.3) 14G 1183.23 30
CLOSED TIPUMBILICAL ARTERY
2 LATERAL EYES REFERENCECATH
LENGTH
Fr (mm) GAUGE cm
3.5 (1.2) 18G 1194.12 40
5 (1.7) 16G 1194.17 40
NEONATAL CATHETER FOR INSERTION IN UMBILICAL VEIN OR ARTERY.
THIS MODEL INCLUDES:
• 1 flexible catheter to avoid perforating the blood vessel, with centimetric markings for perfect insertion control
• 1 proximal female Luer-Lock hub• 1 open or closed rounded distal tip to reduce vascular
trauma
PAEDIATRICS
7
EX P ERT I SE I N C R I T I C A L C A RE
UMBILICAL I Chap. 1
DOUBLE LUMEN OMBILICATH®
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
NEONATAL CATHETER FOR INSERTION IN UMBILICAL VEIN.
THIS MODEL INCLUDES:
• 1 flexible catheter to avoid perforating the blood vessel, with centimetric markings for perfect insertion control
• 1 open and flexible distal tip to reduce vascular trauma • 2 clamps• 2 male Luer-Lock injection caps
DOUBLE LUMEN OMBILICATH®
Ø CATHETERREFERENCE
CATHLENGTH
PORTPRIMING
VOL.FLOW RATE
Fr (mm) GAUGE cm ml ml/min
4 (1.3)
11621.13 15PROXIMAL 0.15 10
DISTAL 0.13 9
11622.13 20PROXIMAL 0.20 9
DISTAL 0.15 8
11623.13 30PROXIMAL 0.25 7
DISTAL 0.20 6
5 (1.7) 11623.17 30
PROXIMAL 0.30 13
DISTAL 0.25 12
20 G 20 G
20 G
18 G
20 G
20 G 20 G
20 G
18 G
20 G
Chapter 2 CENTRAL VENOUS
8
EX P ERT I SE I N C R I T I C A L C A RE
9
EX P ERT I SE I N C R I T I C A L C A RE
Central venous catheters (Seldinger technique)
Single lumen catheters for central venous access are used for:
• Administration of drugs• Central venous pressure monitoring• Transfusion• Parenteral nutrition
Multi-lumen catheters for central venous access (subclavian, jugular or femoral) simplify multiline infusions and avoid “bolus effects”. They are used in the following situations:
• Simultaneous administration of incompatible drugs• Administration of amines• Administration of antibiotics• Measuring the central venous pressure • Blood volume expansion• Parenteral nutrition• Infusion of hyperosmolar solutions (> 700 mOsm)
PAEDIATRICS
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
10
EX P ERT I SE I N C R I T I C A L C A RE
Chap. 2 I CENTRAL VENOUS
THIS MODEL INCLUDES:
• 1 catheter with markings every 5 cm for perfect insertion control
• 1 Biotub® extension line (L = 24 cm), made of two materials providing extreme flexibility and total chemical inertia
• 1 lipid resistant 3-way stopcock • 1 introducing needle• 1 Luer-Lock 12 ml syringe • 1 double flexibility J guidewire or straight guidewire
All products are also available in blister packs.
SINGLE LUMEN SELDIFLEX® (with separate extension line)
SINGLE LUMEN SELDIFLEX® (with separate extension line)
CATHETER REFERENCECATH
LENGTHPRIMING
VOL.FLOW RATE
GUIDEWIRE NEEDLE
Fr (mm) GAUGE STRAIGHT GUIDEWIRE J GUIDEWIRE cm ml ml/min Ø inch (mm)
Length cm
Ø mm (G) – Length (mm)
3 (1.0) 20G
67274.10B*8
25 14.019
(0.48)
30
0.88 mm (20G) – 28 mm
67274.10 67274J10 25 14
67276.10 11 32 12
4 (1.3) 18G
67274.13B* 8 51 38
.024(0.61)
1.07 mm (19G) –
41+55 mm
67276.13B*11
68 36
67276.13 67276J13 68 36
67278.13 15 91 32
* Products with a reference ending with a “B” are available in blister packs
PAEDIATRICS
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
THE INTEGRATED EXTENSION LINE PROVIDES AN ACCESS TO THE SYSTEM DISTANT FROM THE PUNCTURE SITE FOR IMPROVED ASEPSIS.
THIS MODEL INCLUDES:
• 1 introducing needle• 1 double flexibility J guidewire or straight guidewire• 1 catheter
SINGLE LUMEN SELDIFLEX®(with integrated extension line)
SINGLE LUMEN SELDIFLEX® (with integrated extension line)
CATHETER REFERENCECATH
LENGTHPRIMING
VOL.FLOW RATE
GUIDEWIRE NEEDLE
Fr (mm) GAUGESTRAIGHT
GUIDEWIREJ GUIDEWIRE cm ml ml/min
Ø inch (mm)
Length cm
Ø mm (G) - Length (mm)
2 (0.7) 22G
67242.07 67242J07 4 0.10 14
.019(0.48)
300.70 mm (22G) – 19 mm
67243.07 67243J07 6 0.10 10
67244.07 67244J07 8 0.13 1044
67246.07 67246J07 11 0.15 8
3 (1.0) 20G
67242.10 67242J10 4 0.11 18
.019(0.48)
30
0.88 mm (20G) – 28 mm
67243.10 67243J10 6 0.11 14
67244.10 67244J10 8 0.14 13
4467246.10 67246J10 11 0.16 10
67248.10 67248J10 15 0.17 9
4 (1,3) 18G
67243.13 67243J13 6 0.12 42
.024(0.61)
30
1.07 mm (19G) –
41+55 mm
67244.13 67244J13 8 0.15 37
4467246.13 67246J13 11 0.17 30
67248.13 67248J13 15 0.20 30
11
EX P ERT I SE I N C R I T I C A L C A RE
CENTRAL VENOUS I Chap. 2
PAEDIATRICS
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
12
EX P ERT I SE I N C R I T I C A L C A RE
Chap. 2 I CENTRAL VENOUS
THIS MODEL INCLUDES:
• 1 catheter with atraumatic flexible tip and markings every 5 cm for perfect insertion control
• 2 introducing needles• 1 dilator• 1 double flexibility J guidewire or straight guidewire• 2 male Luer-Lock injection caps • 2 clamps of different colours • 1 scalpel• 1 Luer 5 ml syringe• 1 additional fixing wing
DOUBLE LUMEN SELDIFLEX®
DOUBLE LUMEN SELDIFLEX®
CATHETER REFERENCECATH
LENGTHPORT
PRIMING VOL.
FLOW RATE
GUIDEWIRE NEEDLE
Fr (mm) GAUGESTRAIGHT
GUIDEWIREJ GUIDEWIRE cm ml ml/min
Ø inch (mm)
Length cm
Ø mm (G) - Length (mm)
4 (1.3)
67612.13 67612J13 4PROXIMAL 0.10 8
.019(0.48)
30
0.88 mm (20G) -
28+55 mm
DISTAL 0.11 18
67613.13 67613J13 6PROXIMAL 0.14 8
DISTAL 0.13 13
67614.13 67614J13 8PROXIMAL 0.14 7
44
DISTAL 0.12 12
67616.13 67616J13 11PROXIMAL 0.11 8
DISTAL 0.10 10
67618.13 - 15PROXIMAL 0.17 9
DISTAL 0.15 9
5 (1.7)
67612.17 67612J17 4PROXIMAL 0.13 15
.024 (0.61)
30
1.07 mm (19G) -55 mm
DISTAL 0.12 28
67613.17 67613J17 6PROXIMAL 0.15 13
DISTAL 0.14 26
67614.17 67614J17 8PROXIMAL 0.17 11
44
DISTAL 0.14 24
67616.17 67616J17 11PROXIMAL 0.16 10
DISTAL 0.14 21
67618.17 67618J17 15PROXIMAL 0.21 5
DISTAL 0.19 18
20 G 20 G
20 G
18 G
20 G
20 G 20 G
20 G
18 G
20 G
PAEDIATRICS
13
EX P ERT I SE I N C R I T I C A L C A RE
CENTRAL VENOUS I Chap. 2
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
THIS MODEL INCLUDES:
• 1 catheter with an atraumatic flexible tip and markings every 5 cm for perfect insertion control
• 1 introducing needle• 1 dilator• 1 double flexibility J guidewire or straight guidewire• 3 male Luer-Lock injection caps • 3 clamps of different colours• 1 scalpel• 1 Luer 5 ml syringe• 1 additional fixing wing
TRIPLE LUMEN SELDIFLEX®
TRIPLE LUMEN SELDIFLEX®
CATHETER REFERENCECATH
LENGTHPORT
PRIMING VOL.
FLOW RATE
GUIDEWIRE NEEDLE
Fr (mm) GAUGESTRAIGHT
GUIDEWIREJ GUIDEWIRE cm ml ml/min
Ø inch (mm)
Length cm
Ø mm (G) - Length (mm)
5.5 (1.8)
67714.18 67714J18 8
PROXIMAL 0.10 13
.024(0.61) 44
1.07 mm (19G) - 55 mm
MEDIAL 0.11 14
DISTAL 0.12 30
67716.18 67716J18 11
PROXIMAL 0.12 10
MEDIAL 0.13 10
DISTAL 0.15 25
67718.18 67718J18 15
PROXIMAL 0.15 9
MEDIAL 0.17 9
DISTAL 0.20 24
20 G 20 G
20 G
18 G
20 G
PAEDIATRICS
14
EX P ERT I SE I N C R I T I C A L C A RE
Chap. 2 I CENTRAL VENOUS
Central venous catheters for tunnelisation
(Seldinger technique)
The tunnelisation technique offers:
• When accessing the internal jugular vein, a 3-fold reduction of the risk of catheter associated sepsis in ICU patients, and a 4-fold reduction of the risk of catheter associated septicemia
• When accessing the femoral vein, a 4-fold reduction of the risk of sepsis and a 3-fold reduction of the risk of catheter associated septicemia
• Protection of the puncture site with an occlusive dressing• Improvement of patient comfort
Markings on the extension lines help to cut the lines and to fit blunt needles safely.
PAEDIATRICS
15
EX P ERT I SE I N C R I T I C A L C A RE
CENTRAL VENOUS I Chap. 2
THIS MODEL INCLUDES:
• 1 catheter with markings every 5 cm for perfect insertion control
• 1 swaged tunnelisation needle • 1 introducing needle• 1 dilator• 1 double flexibility J guidewire or straight guidewire• 1 detachable blunt hub with fixing wing and nut• 1 obturator for tunnelisation needle • 1 scalpel • 1 Luer 5 ml syringe• 1 additional fixing wing
SINGLE LUMEN HASSELCATH® ( Seldinger technique)
SINGLE LUMEN HASSELCATH® (Seldinger technique)
CATHETER REFERENCECATH
LENGTHFLOW RATE
GUIDEWIRE NEEDLE
Fr (mm) GAUGE STRAIGHT GUIDEWIRE J GUIDEWIRE cm ml/minØ inch (mm)
Length cm
Ø mm (G) – Length (mm)
4 (1.3) 18G 6344.13 - 40 26 .024(0.61) 70 1.07 mm (19G) – 38+55 mm
5 (1.7) 16G6344.17 6344J17 40 38
.035(0.89)
701.24 mm (18G) – 70 mm
6346.17 - 60 78 100
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Chapter 3 ARTERIAL
(SELDINGER TECHNIQUE)
16
EX P ERT I SE I N C R I T I C A L C A RE
Arterial catheters for invasive arterial pressure monitoring and blood sampling.
PAEDIATRICS
17
EX P ERT I SE I N C R I T I C A L C A RE
ARTERIAL (SELDINGER TECHNIQUE) I Chap. 3
EX P ERT I SE I N C R I T I C A L C A RE
THIS MODEL IS DESIGNED IN PTFE FOR IMPROVED GLIDING PER-FORMANCE AND EASIER INTRODUCTION.
THIS MODEL INCLUDES:
• 1 catheter• 1 introducing needle• 1 straight guidewire
PTFE SELDICATH®
PTFE SELDICATH®CATH
LENGTHCATHETER REFERENCE GUIDEWIRE NEEDLE
cm Fr (mm) GAUGESTRAIGHT
GUIDEWIREØ inch (mm)
Length cm
Ø mm (G) – Length (mm)
22 (0.7) 22G 3871.07* .019 (0.48) 22 0.70 mm (22G) - 19 mm
3 (1.0) 20G 3871.10 .019 (0.48) 22 0.88 mm (20G) - 28 mm
3 2 (0.7) 22G 3872.07* .019 (0.48) 22 0.70 mm (22G) - 19 mm
43 (1.0) 20G 3872.10 .019 (0.48) 22 0.88 mm (20G) - 28 mm
4 (1.3) 18G 3872.13 .019 (0.48) 22 1.07 mm (19G) - 38 mm
63 (1.0) 20G 3873.10 .019 (0.48) 22 0.88 mm (20G) - 28 mm
4 (1.3) 18G 3873.13 .024 (0.61) 22 1.07 mm (19G) - 38 mm
153 (1.0) 20G 3881.10 .019 (0.48) 30 0.88 mm (20G) - 28 mm
4 (1.3) 18G 3881.13 .024 (0.61) 30 1.07 mm (19G) - 38 mm
THIS MODEL IS DESIGNED IN PTFE FOR IMPROVED GLIDING PER-
* Neonatal catheters in FEP.
PAEDIATRICS
18
EX P ERT I SE I N C R I T I C A L C A RE
Chap. 3 I ARTERIAL (SELDINGER TECHNIQUE)
THIS MODEL IS DESIGNED IN PU: IT REDUCES THE RISK OF KINKING DURING INSERTION IN THE RADIAL ARTERY, PARTICULARLY IN AGITATED PATIENTS. THE EXTENSION LINE PROVIDES AN ACCESS DISTANT FROM THE PUNCTURE SITE;
THIS MODEL INCLUDES:
• 1 catheter• 1 introducing needle• 1 straight guidewire • 1 safety loop
PU SELDICATH®(with extension line and safety loop)
PU SELDICATH® (with extension line and safety loop)CATH
LENGTHCATHETER REFERENCE GUIDEWIRE NEEDLE
cm Fr (mm) GAUGESTRAIGHT
GUIDEWIREØ inch (mm)
Length cm
Ø mm (G) – Length (mm)
4 3 (0.9) 20G 3842.09 .019 (0.48) 30 1.88 mm (20G) - 28 mm
63 (0.9) 20G 3843.09 .019 (0.48) 30 0.88 mm (20G) - 40 mm
4 (1.2) 18G 3843.12 .024 (0.61) 30 1.07 mm (19G) - 38 mm
83 (0.9) 20G 3844.09 .019 (0.48) 30 0.88 mm (20G) - 40 mm
4 (1.2) 18G 3844.12 .024 (0.61) 30 1.07 mm (19G) - 38 mm
Chapter 4 RESPIRATORY TRACT
19
EX P ERT I SE I N C R I T I C A L C A RE
PAEDIATRICS
20
EX P ERT I SE I N C R I T I C A L C A RE
Chap. 4 I RESPIRATORY TRACT
Pleural drainage
Fast, simple, effective and reliable chest drainage catheters used to:
• Eliminate leaking : fluid : hemothorax, pyothorax, or serofibrinous pleurisy, Gaz : pneumothorax.
• Restore negative pressure in the pleural space and secure the re-expansion of a retracted lung.
PAEDIATRICS
21
EX P ERT I SE I N C R I T I C A L C A RE
RESPIRATORY TRACT I Chap. 4
TYPICALLY, A PNEUMOTHORAX IS DRAINED VIA THE 2ND OR 3RD INTERCOSTAL SPACE ON THE MEDIOCLAVICULAR LINE, AND AN EFFUSION IS DRAINED VIA THE 6TH OR 7TH INTERCOSTAL SPACE ON THE MID-AXILLARY LINE. THE MATERIAL USED IS THERMOSENSITIVE AND SOFTENS WHEN IN CONTACT WITH BODY TEMPERATURE.
THIS MODEL INCLUDES:
• 1 introducing needle• 1 multiperforated drain with integrated 3-way stopcock • 1 straight guidewire• 1 conical hub for 6-13 mm aspiration tube• 1 Luer-Lock 10 ml syringe• 1 dilator• 1 connecting tube
PLEUROCATH® (Seldinger technique)
PLEUROCATH® (Seldinger technique)
DRAINREFERENCE
DRAIN LENGTH
GUIDE DILATOR NEEDLE
Fr (mm)PERFORATED
ALONGcm
Ø inch (mm)
Length cm
Ø ext. (mm)
Length cm
Ø mm (G) – Length (mm)
12 (4.0) 3 cm 5354.40* 40 .035(0.89) 70 12 11 1.47 mm (17G) - 90 mm
* Round and blunt tip model supplied with a Tuohy needle (curved tip)
PAEDIATRICS
22
EX P ERT I SE I N C R I T I C A L C A RE
Chap. 4 I RESPIRATORY TRACT
PLEUROCATH®
PLEUROCATH®
NEONATAL DRAINREFERENCE
DRAIN LENGTH
NEEDLE
Fr (mm)PERFORATED
ALONGcm GAUGE Ø mm (G) – Length (mm)
6 (2.0) 3 cm 5323.20 30 13G 2.42 mm (13G) - 57 mm
PEDIATRIC DRAINREFERENCE
DRAIN LENGTH
NEEDLE
Fr (mm)PERFORATED
ALONGcm GAUGE Ø mm (G) – Length (mm)
8 (2.7) 4 cm 5324.27 40 10G 3.32 mm (10G) - 77 mm
TYPICALLY, A PNEUMOTHORAX IS DRAINED VIA THE 2ND OR 3RD INTERCOSTAL SPACE ON THE MEDIOCLAVICULAR LINE, AND AN EFFUSION IS DRAINED VIA THE 6TH OR 7TH INTERCOSTAL SPACE ON THE MID-AXILLARY LINE. IN CASE OF LOCAL CAUSES (TRAUMA, SCARING…), OR IF THE EFFUSION HAS BECOME PARTITIONED, ANOTHER DRAINAGE POINT MAY BE CHOSEN.
THIS MODEL INCLUDES:
• 1 introducing needle• 1 drain multiperforated on 10 cm (in a sterile handling
sheath) • 1 three-way stopcock• 1 conical hub for 6-13 mm aspiration tube• 1 connecting tube
PAEDIATRICS
23
EX P ERT I SE I N C R I T I C A L C A RE
RESPIRATORY TRACT I Chap. 4
Bronchial sampling
Devices for the diagnosis of nosocomial pneumopathies in ventilated patients.
• Simple technique • Fast• Atraumatic• Reliable
If a nosocomial pneumopathy is suspected in a ventilated patient, a protected device should be used to avoid oropharyngeal contamination of the sample (double catheter sealed with a resorbable polyethylene glycol cap).
PAEDIATRICS
24
EX P ERT I SE I N C R I T I C A L C A RE
Chap. 4 I RESPIRATORY TRACT
COMBICATH® FOR PROTECTED DISTAL BRONCHIAL SAMPLING
DEVICE FOR PROTECTED DISTAL BRONCHIAL SAMPLING:
INTRODUCED VIA THE ANGLED CONNECTOR OF ENDOTRACHEAL TUBE OR TRACHEOTOMY CANNULADIRECT BACTERIOLOGICAL EXAMINATION / CULTURE.
Review of clinical dataSensitivity 54% to 92%Specificity 83% to 100%
THIS MODEL INCLUDES:
• 1 outer catheter sealed with a hydrosoluble PEG plug• 1 inner catheter • 1 spacer• 1 protection sheath
INTRODUCED VIA THE ANGLED CONNECTOR OF ENDOTRACHEAL
COMBICATH® FOR PROTECTED DISTAL BRONCHIAL SAMPLING
WITH 2 PAIRS OF SINGLE USE SCISSORS:
REFERENCEOUTER CATHETER INNER CATHETER
Ø ext. mm Length cm Ø ext. mm Length cm
58223.19 1.9 35 1.0 38
REFERENCEOUTER CATHETER INNER CATHETER
Ø ext. mm Length cm Ø ext. mm Length cm
58223.19C2 1.9 35 1.0 38
Chapter 5ACCESSORIES
25
EX P ERT I SE I N C R I T I C A L C A RE
26
EX P ERT I SE I N C R I T I C A L C A RE
PAEDIATRICS
Chap. 5 I ACCESSORIES
THIS MODEL INCLUDES:
• 1 introducing needle• 1 dilator• 1 straight guidewire • 1 sheath to introduce catheters,
cardiovascular catheters, etc.
DESIL-INTRO® Standard
DESIL-INTRO® Standard
CATHETERREFERENCE
SHEATH LENGTH
DILATORSTRAIGHT
GUIDEWIRENEEDLE
Fr (mm) COLOR cm Length cmØ inch (mm)
Length cm
Ø mm (G) – Length (mm)
4 (1.3) RED 2874.137,5 14
.024 (0.61)
30
1.07 mm (19G) - 38 mm
5 (1.7) SILVER 2874.17
.035(0.89)
1.24 mm (18G) - 55 mm
5 (1.7) SILVER 2875.17
11,5 21 44 1.24 mm (18G) - 70 mm
6 (2.0) GREEN 2875.20
7 (2.3) ORANGE 2875.23
Introducers and needlesThe introducers are placed in the vascular system using the Seldinger technique.
où l’ensemble gaine / dilatateur est introduit
27
EX P ERT I SE I N C R I T I C A L C A RE
PAEDIATRICS
ACCESSORIES I Chap. 5
THIS MODEL INCLUDES:
• 1 introducing needle• 1 dilator• 1 double flexibility J guidewire• 1 peel-away sheath to introduce catheters,
cardiovascular catheters, etc.
DESIL-INTRO® Peel-away sheath
DESIL-INTRO® Peel-away sheath
CATHETERREFERENCE
SHEATH LENGTH
DILATOR J GUIDEWIRE NEEDLE
Fr (mm) COLOR cm Length cmØ inch (mm)
Length cm
Ø mm (G) – Length (mm)
4 (1.3) RED 2867.13
13,5 20
.024 (0.61)
44
1.07 mm (19G) - 55 mm
5 (1.7) SILVER 2867.17
.035(0.89)
1.24 mm (18G) - 70 mm
6 (2.0) GREEN 2867.20
7 (2.3) ORANGE 2867.23
28
EX P ERT I SE I N C R I T I C A L C A RE
PAEDIATRICS
Chap. 5 I ACCESSORIES
THIS MODEL INCLUDES:
• 1 introducing needle• 1 dilator• 1 straight guidewire • 1 pre-split sheath to introduce catheters,
cardiovascular catheters, etc.
DESIL-INTRO® Pre-split sheath
DESIL-INTRO® Pre-split sheath
CATHETERREFERENCE
SHEATH LENGTH
DILATORSTRAIGHT
GUIDEWIRENEEDLE
Fr (mm) COLOR cm Length cmØ inch (mm)
Length cm
Ø mm (G) – Length (mm)
6 à 7 (2.0 à 2.3) SILVER 2857.20 13.5 21 .035(0.89) 441.24 mm (18G) -
70 mm
29
EX P ERT I SE I N C R I T I C A L C A RE
PAEDIATRICS
ACCESSORIES I Chap. 5
NEEDLE TO INTRODUCE A CATHETER OR A GUIDEWIRE.
THIS MODEL INCLUDES:
• 1 introducing needle
MICRODARD® NEEDLE
MICRODARD® NEEDLENEEDLE
REFERENCEFOR CATHETER
Ø mm (G) – Length (mm) Fr / mm
1.42 mm (17G) - 75 mm 1917.10 3 (1.0)
NEEDLEREFERENCE
FOR GUIDE
Ø mm (G) – Length (mm) " / inch
0.88 mm (20G) - 28 mm 1912.13 .019 et .025
0.88 mm (20G) - 55 mm 1935.07 .019 et .025
30
EX P ERT I SE I N C R I T I C A L C A RE
PAEDIATRICS
Chap. 5 I ACCESSORIES
FLAT FILTER for paediatric IV infusion
Infusion filters
FLAT FILTER TO ELIMINATE PARTICLES, BACTERIA AND AIR BUBBLES IN THE INFUSION LINE. THE FILTER MUST BE FITTED ONTO THE INFUSION LINE AS CLOSE AS POSSIBLE TO THE CATHETER. IT CAN BE USED WITH AN INFUSION PUMP OR A GRAVITY INFUSION SET.
• Porosity: 0.2 μm• Diameter: 25 mm• Total filtering surface area: 4.3 cm²• Pressure resistance: 45 psi (3 bar)• Flow rate (under 90 cm H2O): 10 ml/min• Priming volume: 0.7 ml• 1 air outlet: 0.02 μm hydrophobic membrane• Female Luer-Lock inlet connector,
male Luer-Lock outlet connectorREFERENCE 6932.002
31
EX P ERT I SE I N C R I T I C A L C A RE
PAEDIATRICS
ACCESSORIES I Chap. 5
THE KIT INCLUDES:
• 1 detachable blunt needle with fixing wing and nut • 1 stylet• 1 safety clamp
REPAIR KIT for Hasselcath®
These kits contain spare parts for various Plastimed devices.
REFERENCE REPAIR KIT
98634.13* FOR HASSELCATH 4 Fr
98634.17 FOR HASSELCATH 5 Fr
REPAIR KIT FOR HASSELCATH®
Repair kits
* Model supplied with a clamping device instead of the nut.
32
EX P ERT I SE I N C R I T I C A L C A RE
PAEDIATRICS
Chap. 5 I ACCESSORIES
THIS MODEL INCLUDES:
• Male, female caps• Male/male hubs, female/female hubs• Male or female hubs/ catheter tip• Y connectors• Female Luer Lock hubs.
HUBS AND CAPS
REFERENCE DESIGNATION QUANTITY PER BOX
9911.55 CAP FEMALE LL 50
9925.17 HUB MLL/M CONICAL Ø 6 TO 12 mm 25
9935.17 HUB FLL/M CONICAL Ø 6 TO 12 mm 50
9952.44 HUB Y, 1 MLL/2 FLL 25
9928.77 HUB MALE/MALE LL 50
9929.77 HUB MLL/MLL ROTATIVE 50
9939.22 HUB FEMALE/FEMALE LL 50
HUBS AND CAPS
Hubs and capsCaps, hubs, Y connectors for infusion, pressure and drainage lines.
où l’ensemble gaine / dilatateur est introduit
33
EX P ERT I SE I N C R I T I C A L C A RE
PAEDIATRICS
ACCESSORIES I Chap. 5
THIS MODEL INCLUDES:
• 1 guidewire protector• 1 protective cap• 1 guidewire
GUIDEWIRE
Other accessoriesoù l’ensemble gaine / dilatateur est introduit
GUIDEWIRE
REFERENCEGUIDE
Ø inch (mm) Length cm SHAPE
4812.19 .019 (0.48) 44 STRAIGHT 1 RIGID END / 1 FLEXIBLE END4812.24 .024 (0.61) 44 STRAIGHT
4830.19 .019 (0.48) 30 J‘’J’’ 3 mm,
DOUBLE FLEXIBILITY END(J AND STRAIGHT)
4892.35 .035 (0.89) 44 J
4894.35C* .035 (0.89) 70 J
4895.35* .035 (0.89) 100 J
* Marked model
Measuring unit conversion tables
LENGTHS
inch mm
1/16 1.6
1/8 3.2
1/4 6.35
3/8 9.5
1/2 12.7
5/8 16
3/4 19
1 25.4
1 1/4 32
1 1/2 38
1 1/3 44
2 50.8
2 1/4 57
2 1/2 63
2 3/4 70
3 76
3 1/4 82
3 1/2 90
4 102
5 127
6 152
7 178
8 203
9 229
10 254
foot cm
1 30.5
2 61
3 91
3.28 100
4 122
5 152
6 183
10 305
TEMPERATURES
C° F°
200° 392°
130° 266°
100° 212°
40° 104°
39,4° 103°
38,9° 102°
38,3° 101°
37,8° 100°
37,2° 99°
36,2° 98°
36,1° 97°
0° 32°
WEIGHT
1 pound (lb) = 0.450 Kg
1 kg = 2.21 pounds (lb)
SURFACES
SQUARE INCH sq. in = 6.451 cm2
SQUARE CENTIMETER cm2 = 0.155 sq. in
LINE PRIMING VOLUMES
Interior Ø Volume per 10 cm
1 mm 8 mm3 0.08 ml
1.5 mm 0.15 cm3 0.15 ml
2 mm 0.31 cm3 0.31 ml
2.5 mm 0.49 cm3 0.49 ml
VOLUMES
CUBIC FOOT cu. ft. = 28.317 dm3
CUBIC DECIMETRE dm3 = .0035 cu. ft.
CUBIC INCH cu. in. = 16.387 cm3
CUBIC CENTIMETER cm3 = .06 cu. in.
U.S. GALLON u.s. gal. = 3.7854 l
LITER l = .274 u.s. gal.
BRITISH GALLON Br. gal. = 4.5461 l
LITER l = .22 Br. gal.
PRESSURES
POUND / SQUARE INCH (p.s.i) = 0.068 cm2
1 kg / cm2 = 1 bar = 1.47 p.s.i
NEEDLES OUTER DIAMETERS
U.S. GAUGE inch mm
30 .012 0.31
29 .013 0.33
28 .014 0.36
27 .016 0.41
26 .018 0.46
25 .020 0.51
24 .022 0.56
23 .025 0.63
22 .028 0.71
21 .032 0.81
20 .035 0.89
19 .042 1.10
18 .049 1.24
17 .058 1.47
16 .065 1.65
15 .072 1.83
14 .083 2.11
13 .095 2.41
12 .109 2.77
11 .120 3.05
10 .134 3.40
10 .148 3.76
10 .165 4.20
10 .180 4.57
NEEDLES OUTER DIAMETERS
inch mm Ch=FG=Fr
.013 0.33 1
.019 0.48
.020 0.51
.021 0.53
.023 0.58
.024 0.61
.025 0.63
.028 0.71
.032 0.81
.035 0.89
.038 0.97
.0394 1
.043 1.09
.045 1.14
.0524 1.33 4
.059 1.50 4.5
.060 1.52
.066 1.67 5
.068 1.73
.071 1.80
.075 1.90
.079 2 6
.083 2.12
.087 2.21
.090 2.29
.092 2.33 7
.095 2.41
.098 2.49
0.100 2.54
0.102 2.60
0.105 2.67 8
0.110 2.80
0.118 3 9
0.131 3.33 10
0.144 3.67 11
0.157 4 12
0.170 4.33 13
0.184 4.67 14
0.197 5 15
0.209 5.33 16
0.236 6 18
0.263 6.67 20
0.275 7 21
0.288 7.33 22
0.316 8 24
0.354 9 27
0.394 10 3034
EX P ERT I SE I N C R I T I C A L C A RE
REFERENCE PAGE
11621.13 7
11622.13 7
11623.13 7
11623.17 7
1183.12 6
1183.17 6
1183.23 6
1194.12 6
1194.17 6
1912.13 29
1917.10 29
1935.07 29
2857.20 28
2867.13 27
2867.17 27
2867.20 27
2867.23 27
2874.13 26
2874.17 26
2875.17 26
2875.20 26
2875.23 26
3842.09 18
3843.09 18
3843.12 18
3844.09 18
3844.12 18
3871.07 17
3871.10 17
3872.07 17
3872.10 17
3872.13 17
3873.10 17
3873.13 17
3881.10 17
3881.13 17
4812.19 33
4812.24 33
4830.19 33
4892.35 33
4894.35C 33
4895.35 33
5323.20 22
5324.27 22
REFERENCE PAGE
5354.40 21
58223.19 24
58223.19C2 24
6344.13 15
6344.17 15
6344J17 15
6346.17 15
67242.07 11
67242.10 11
67242J07 11
67242J10 11
67243.07 11
67243.10 11
67243.13 11
67243J07 11
67243J10 11
67243J13 11
67244.07 11
67244.10 11
67244.13 11
67244J07 11
67244J10 11
67244J13 11
67246.07 11
67246.10 11
67246.13 11
67246J07 11
67246J10 11
67246J13 11
67248.10 11
67248.13 11
67248J10 11
67248J13 11
67274.10 10
67274.10B 10
67274.13B 10
67274J10 10
67276.10 10
67276.13 10
67276.13B 10
67276J13 10
67278.13 10
67612.13 12
67612.17 12
REFERENCE PAGE
67612J13 12
67612J17 12
67613.13 12
67613.17 12
67613J13 12
67613J17 12
67614.13 12
67614.17 12
67614J13 12
67614J17 12
67616.13 12
67616.17 12
67616J13 12
67616J17 12
67618.13 12
67618.17 12
67618J17 12
67714.18 13
67714J18 13
67716.18 13
67716J18 13
67718.18 13
67718J18 13
6932.002 30
98634.13 31
98634.17 31
9911.55 32
9925.17 32
9928.77 32
9929.77 32
9935.17 32
9939.22 32
9952.44 32
Reference index
35
EX P ERT I SE I N C R I T I C A L C A RE
The descriptions and images in this catalogue are not legally binding.
www.plastimed.fr www.prodimed.com
Sales Department6 rue Louis Armand95130 Le Plessis Bouchard - FRANCETelephone: +33 (0)1.34.44.15.15 – Fax: +33 (0)1.30.72.22.08Email: [email protected]
ManufacturerProdimed 6 rue Louis Armand95130 Le Plessis Bouchard - FRANCE
SYS 1911 - catped-VA-v1-2012