Preliminary results of ANAIS-25 J. Amaré, S. Cebrián, C. Cuesta, E. García, C. Ginestra, M. Martínez, M. A. Oliván, Y. Ortigoza, A. Ortiz de Solórzano, C. Pobes, J. Puimedón, M. L. Sarsa , P. Villar and J. A. Villar.

Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

Preliminary results of ANAIS-25

J. Amaré, S. Cebrián, C. Cuesta, E. García, C. Ginestra, M. Martínez, M. A. Oliván, Y. Ortigoza, A. Ortiz de Solórzano,

C. Pobes, J. Puimedón, M. L. Sarsa , P. Villar and J. A. Villar.

Page 2: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

OUTLINE

1. ANAIS EXPERIMENT

2. EXPERIMENTAL SET-UP: ANAIS-0 AND ANAIS-25

3. LIGHT COLLECTION

4. BACKGROUND

5. EVENTS SELECTION

6. NaI(Tl) SCINTILLATION CONSTANTS

C. Cuesta 2

Page 3: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

1. ANAIS EXPERIMENT

ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain), a 250 kg potassium-purified NaI(Tl) experiment to look for dark matter.

MotivationStudy of the annual modulationDAMA/LIBRA positive signal. CoGeNT, CRESST, CDMS-Si results as another hint.

Technical aspects:

• 20 NaI(Tl) crystals of 12.5 kg.

• Coupled each one to 2 PMTs.

• Shielded from external radiation.

Experimental goals:

• Energy threshold < 2 keVee.

• Background at low energy as low as possible.

• Very stable operation conditions.

C. Cuesta 3

40 cm neutron shielding

Active vetoes

Anti-Rn box

10 cm ancient lead

20 cm lead

Page 4: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

2. EXPERIMENTAL SET-UP: ANAIS-0 MODULE

C. Cuesta

NaI(Tl) (9.6kg) old crystal made by St Gobain.

254x101.6x101.6mm3

Measurements from April 2009 to November 2012

at the Canfranc Underground Laboratory to:

• Characterize ANAIS background.

• Optimize events selection.

• Design the calibration method.

• Test the acquisition code and electronics.

• Determine the optimum configuration of photomultipliers and light guides.

Copper encapsulation allowing different configurations and tests of PMTs.

PMT NaI(Tl) PMT

Set-up PMT Light guides

1 ET LB No

2 Ham LB Yes

3 Ham ULB Yes

4 Ham ULB No

5 Ham VLB No

PMT LG NaI(Tl) LG PMT

Mylar window allowing low energy calibrations.

4

Page 5: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

2. EXPERIMENTAL SET-UP: ANAIS-25 ULTRAPURE NaI(Tl) CRYSTALS

C. Cuesta

2 ultrapure NaI(Tl) (12.5 kg) crystals made by Alpha Spectra.

4.75“ x 11.75"

Measurements from December 2012 at the new facilities of the LSC to determine their bulk contamination:

• 40K coincidence measurement to quantify potassium

contamination. (Ultrapure NaI powder < 100 ppb K ).

• 232Th and 238U natural chains content.

Detector PMT Light guides

0 Ham VLB No

1 Ham ULB No

OFHC copper encapsulated.Tightly closed with quartz windows.PMTs coupled at the LSC clean room.

Mylar window allowing low energy calibrations.

D0

D1

5

Page 6: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

2. EXPERIMENTAL SET-UP: HUT, SHIELDING AND ELECTRONICS

• Hut and control room : already constructed @ LSC Hall B.

• ANAIS-0 and ANAIS-25 shielding:

– 10 cm roman lead + 20 cm lead.

– Active vetoes anti-muons (partial coverage).

– Anti-radon box.

– Neutron shielding (to be accomplished).

• VME electronics and final acquisition software and hardware fully commissioned and tested for 2 channels. All the modules for the whole experiment purchased.

C. Cuesta

ANAIS-0 set-up

6

Page 7: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

Several models tested in ANAIS-0 to decide the model to be used in ANAIS.

The radioactivity levels have been measured with a HP Ge detector at LSC:

3. LIGHT COLLECTION: PHOTOMULTIPLIERS

C. Cuesta

40K

(mBq/PMT)

232Th

(mBq/PMT)

238U

(mBq/PMT)

60Co

(mBq/PMT)

Low background

Electron Tubes Limited 9302B420 50 24 4 220 12 -

Low background

Hamamatsu R6233-100 MOD678 42 68 3 100 3 -

Ultra low background

Hamamatsu R11065SEL12 7 3.6 1.2

238U - 47 28 226Ra – 8.0 1.2

4.1 0.7

Very low background

Hamamatsu R6956 MOD SEL97 19 20 2

238U - 128 38 226Ra – 84 3

-

ET LB Ham LB Ham ULB Ham VLB

7

QE min @420 nm: 32 % <30%> 33%

Page 8: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

40K

(mBq/PMT)

232Th

(mBq/PMT)

238U

(mBq/PMT)

60Co

(mBq/PMT)

Low background

Electron Tubes Limited 9302B420 50 24 4 220 12 -

Low background

Hamamatsu R6233-100 MOD678 42 68 3 100 3 -

Ultra low background

Hamamatsu R11065SEL12 7 3.6 1.2

238U - 47 28 226Ra – 8.0 1.2

4.1 0.7

Very low background

Hamamatsu R6956 MOD SEL97 19 20 2

238U - 128 38 226Ra – 84 3

-

3. LIGHT COLLECTION: PHOTOMULTIPLIERS

C. Cuesta

ET LB Ham LB Ham ULB Ham VLB

8

QE min @420 nm: 32 % <30%> 33%

Best options to be considered are tested in ANAIS-25:ULB: Very low background levels . VLB: High QE and veryconvenient rapportradioactivity-price.

Page 9: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

3. LIGHT COLLECTION: S.E.R. and phe./keV

Single Electron Response:

• Algorithm to identify single peaks in the pulse.

• S.E.R.: Derived from the last peak identified in the pulse.

Phe./keV: 22.6 keV (109Cd) area compared to S.E.R. area.

Results:

• VLB PMTs seem a good option: better Q.E. than ULB although worse bkg.

• ANAIS-25: Significant improvement in light collection.

Set-up PTM Light guides

Phe-/keV

ANAIS-0 set-up 4 Ham ULB No 5.34 ± 0.05

ANAIS-0 set-up 5 Ham VLB No 7.38 ± 0.07

ANAIS-25 detector 0 Ham VLB No 16.13 ± 0.66

ANAIS-25 detector 1 Ham ULB No 12.58 ± 0.13

C. Cuesta

3.2 keV event (40K) ANAIS-0 VLB PMTs

0 100 200 300 4001

10

100

0 100 200 300 400 500 6001

10

100 S.E.R.

ANAIS-25

VLB PMTsC

ou

nts

Area (mV·ns)

S.E.R.

ANAIS-0

VLB PMTs

Co

un

ts

Area (mV·ns)

3.2 keV event (40K) ANAIS-25 VLB PMTs

9

Page 10: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

3. LIGHT COLLECTION: RESOLUTION

Results:

• VLB PMTs seem a good option: better Q.E. than ULB although worse bkg.

• ANAIS-25: Significant improvement in light collection.

Set-up PTM Light guides

Resolution (/E) (%)

14.4 keV 122.1 keV

ANAIS-0 set-up 3 Ham ULB Yes 17.60 7.18

ANAIS-0 set-up 4 Ham ULB No 14.36 6.34

ANAIS-0 set-up 5 Ham VLB No 15.18 5.88

ANAIS-25 Detector 0 Ham VLB No 10.20 4.11

ANAIS-25 Detector 1 Ham ULB No 10.00 3.91

C. Cuesta

0 20 40 60 80 100 120 1400

100

200

300

FW

HM

2 (

keV

2)

Energy (keV)

ANAIS-25, ULB PMTs

ANAIS-25, VLB PMTs

ANAIS-0, ULB PMTs

ANAIS-0, VLB PMTs

10

Page 11: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

3. LIGHT COLLECTION: PHOTOMULTIPLIERS

C. Cuesta 11

After the light collection and background measurements, the VLB model has been chosen:

42 units of the Hamamatsu R12669-SEL2 model have been ordered.

• Dark current <500 Hz.

• Quantum efficiency >33 % at 420 nm.

• Radioactivity of each unit will bescreened at the LSC HP Ge spectrometers.Radioactivity results for one unit:

If possible light guides will be avoided (30 % more light).

40K 232Th 238U

mBq/PMT

97 19 20 2238U - 128 38

226Ra – 84 3

Page 12: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

0 10 20 30 40 50 60 70 80 90 1001101201301401

10

ANAIS-0 ULB PMTs

ANAIS-0 VLB PMTs

ANAIS-25 ULB PMTs

ANAIS-25 VLB PMTs

cpd

/keV

/kg

Energy (keV)

4. BACKGROUND: RAW BACKGROUND

C. Cuesta

Results:

• PMT background contribution can be seen at medium and high energy, but the effect of VLB PMTs without light guides seems to be minor in the LE region .

• Lower background in ANAIS-25 data above 100 keV. Below 100 keVbackground is dominated by cosmogeniccontributions.500 1000 1500 2000

10-1

100

ANAIS-0 ULB PMTs

ANAIS-0 VLB PMTs

ANAIS-25 ULB PMTs

ANAIS-25 VLB PMTs

cp

d/k

eV

/kg

Energy (keV)

Cosmogenic lines and 222Rn in air present in first weeks of ANAIS-25 data.

No filtering applied.

12

Page 13: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

0 1 2 3 4 5 610

-3

10-2

10-1

100

101

102

ANAIS-0

ANAIS-25 detector 0

ANAIS-25 detector 1

cp

d/k

eV

/kg

Energy (keV)

4. BACKGROUND: 40K BULK CONTENT

C. Cuesta

Measurement in coincidence

We search for 3.2 keV in one detector and 1460.9 keV in the other.

Efficiency of the coincidence determined by MC.

40Ca

γ 1460.9 keV (10.55%)

40K (T1/2 = 1.2504·109 years)

40Ar

E.C. (10.75%) Q = 1504.69 keVβ- (89.25%) Q = 1311.07 keV

0.2%

Detector K content (ppb)

ANAIS-0 420 20

ANAIS-25 41.7 3.7

13

ANAIS-25 D1

ANAIS-25 D0 40K→40Ar

3.2keV

1460.9 keV

Page 14: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

ANAIS-0

1) events can be discriminated from β by PSA.

2) - events from Bi-Po sequences have been identified and used for calibration of the spectrum.

3) spectrum has been fitted allowing broken equilibrium in natural chains.

ANAIS-25

High rate 3.15 mBq/kg.

• Thorium chain seems very suppressed.

• Measurements on-going to better calibrate and determine activities in the 238U chain.

4. BACKGROUND: 232Th and 238U CHAINS

C. Cuesta

ANAIS-0

Parent Isotope Activity (mBq/kg)

232Th 0.013 0.005

228Th 0.035 0.003

238U / 234U 0.075 0.005

230Th 0.023 0.007

226Ra 0.098 0.004

210Pb 0.188 0.005

2 3 4 5 6 7 8 9 10 11 1210

-4

10-3

10-2

10-1

Experimental Measurement

Fit

cp

d/k

eV

/kg

Alpha energy (keV)

ANAIS-25

ANAIS-0

14

Page 15: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

Fast commissioning and good resolution.With the difference from the first week of measurements and a week 70 days after, several isotopes identified:

4. BACKGROUND: ANAIS-25 COSMOGENIC ACTIVATION

C. Cuesta 15

Isotope Lifetime DecayMain

emissions

125I 59.4 d EC 35.5

126I 13.11 d EC, - 666.0

121mTe 154 d IT, EC 294.0

121Te 16.8 d EC507.6,

573.1

123Te 119.7 d IT 247.6

125mTe 57.4 d IT 144.8

127mTe 109 d IT, - 88.3

0 200 400 600 800 100010

-1

100

101 Detector 0

Cosmogenic activation

cpd

/keV

/kg

Energy (keV)

0 20 40 60 80 100 120 1400

10

20

30

40

50Detector 1

Cosmogenic

activation

cpd

/keV

/kg

Energy (keV)

222Rn in air present in in the first week of data.

L/K shell binding energies from Sb/Te following EC in Te/I.

127mTe125mTe

125I

126I121Te

121mTe

123Te

Page 16: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

PMT NaI(Tl) PMT

• Geant4.9.4.p01: Energy conservation in the decays has been checked.

Some improvements in the code with respect to previous versions.

• ANAIS-0 geometry

• ANAIS-25 geometry

4. BACKGROUND: BACKGROUND MODEL

C. Cuesta

PMT LG NaI(Tl) LG PMT

Quartz windows

Optional light guidesCopper encapsulation

Shielding:

10 cm roman lead

20 cm leadOptional calibration source

16

Page 17: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

Complete background model developed.

• Bulk contaminations in NaI(Tl) crystal of:

40K Coincidence measurement

232Th, 228Th, 238U, 234U, 226Ra and 210Pb PSA

129I 9.01 mBq/crystal, NIM A 592 (2008) 297

• Photomultipliers contaminations (HPGe).

• Upper limits for contamination in quartz windows, light guides, copper, roman lead and optical grease (HPGe).

• Radon content in the air filling the inner volume of the shielding.

• At low energy we find some non-explained components: we have considered some hypotheses to explain those events but no “fitting“ has been tried.

– Addition of 210Pb contamination at the surfaces of NaI(Tl) crystal and copper encapsulation.

– Addition of 210Pb contamination at shielding.

– Addition of 3H contamination in the bulk of the NaI(Tl).

– Increase in the 129I at NaI(Tl) activity previously assumed .

– Some upper limits (238U and 232Th) have been reduced.

4. BACKGROUND: ANAIS-0 BACKGROUND MODEL

C. Cuesta[Astrop. 37 (2012) 60-69]

0 500 1000 1500 2000 2500 300010

-3

10-2

10-1

100

101

cpd

/keV

/kg

Energy (keV)

0 20 40 60 80 100 120 14010

0

101

ANAIS-0

Experimental data

MC simulation with hypotheses

MC simulation: bulk 40

K

cpd

/keV

/kg

Energy (keV)

17

Page 18: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

Preliminary results:

• Bulk contaminations in NaI(Tl) crystal of:

40K 1.25 mBq/kg, coincidence measurement.

210Pb 3.15 mBq/kg, total alpha activity assumption.

129I 0.94 mBq/kg, NIM A 592 (2008) 297.

On-going simulations for the rest of components.

4. BACKGROUND: ANAIS-25 BACKGROUND MODEL

C. Cuesta

0 20 40 60 80 100 120 14010

-2

10-1

100

101

102

Detector 0

Detector 1

cp

d/k

eV

/kg

Energy (keV)600 800 1000 1200 1400 1600 1800 2000

10-4

10-3

10-2

10-1

100

Detector 0

Detector 1cp

d/k

eV

/kg

Energy (keV)

18

Page 19: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

5. EVENTS SELECTION: ANAIS-0

C. Cuesta

A protocol to reject non NaI(Tl) scintillation events developed:

• Periods of anomalous high rate are not considered.

• Muon related events are rejected.

• NaI(Tl) scintillation events selected through:

– number of photoelectrons (n > 3).

– p1 parameter.

Efficiency checked with calibrations down to 2 keVee.

)ns6000(2Area)ns6000(1Area

)ns600100(2Area)ns600100(1Area1p

Background

57Co

2 acceptance

0 10 20 30 40 50 60 70 801

10

ANAIS-0

VLB PMTs

ULB PMTs

cp

d/k

eV

/kg

Energy(keV)

19

Page 20: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

5. EVENTS SELECTION: ANAIS-25

C. Cuesta

A protocol to reject non NaI(Tl) scintillation events is being developed:

• Periods of anomalous high rate are not considered

• Rejection of muon related events. Not yet applied.

• NaI(Tl) scintillation events selected through:

– number of photoelectrons (nULV > 3 & nVLB>5).

– p1 parameter. Not yet applied.

Further efforts to determine the effective experimental threshold. Threshold below 2 keVee could be achieved.

ANAIS-25 D1Background

Low energy response carefully studied for ANAIS-0 and and in progress for ANAIS-25 data:• Trigger efficiency at phe. level.• Low energy calibrations (including a neutron calibration).• Asymmetry in the sharing of the energy between the two PMT signals.• Muon related events identification.

0 10 20 30 40 50 60 70 801

10

ANAIS-0 ULB PMTs

ANAIS-0 VLB PMTs

ANAIS-25 ULB PMTs

ANAIS-25 VLB PMTs

cp

d/k

eV

/kg

Energy (keV)

Cosmogenic lines present in ANAIS-25 data.

20

Page 21: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

• We have determined in a precise way the time constants of the NaI(Tl) phosphorescence.

• A long-life scintillation component in NaI put in evidence after muon energy deposition in ANAIS-0, Prototype III, ANAIS-25 detector 0 and detector 1 (but with different amplitude).

• Differences observed between and interactions (especially in amplitude).

6. NaI(Tl) SCINTILLATION CONSTANTS

C. Cuesta 21

0 50 100 150 200 250 30010

-2

10-1

100

101

ANAIS-0

interactions

interactions

N.

of

ph

e.

(a.u

.)

Time (ms)

0 50 100 150 200 250 30010

-2

10-1

100

N.

of

ph

e.

(a.u

.)

Prototype III

interactions

interactions

Time (ms)0 50 100 150 200 250 300

10-1

100

N.

of

ph

e.

(a.u

.)

Detector 0

interactions

interactions

Time (ms)

0 50 100 150 200 250 30010

-1

100

N.

of

ph

e.

(a.u

.)

Detector 1

interactions

interactions

Time (ms)

Detector 1(ms) 2(ms)

ANAIS-0 10.7 ± 0.3 22.7 ± 2.3 79.0 ± 0.3 92.3 ± 1.6

PIII 34.2 ± 4.7 19.8 ± 10.3 81.7 ± 4.1 75.77 ± 2.7

Detector 0 54.1 ± 3.8 52.5 ± 2.4 174.4 ± 17.5 171.5 ± 4.2

Detector 1 42.2 ± 7.2 59.6 ± 3.1 128.6 ± 12.8 186.7 ± 9.7

Page 22: Preliminary results of ANAIS-25 - Agenda (Indico) · 1. ANAIS EXPERIMENT ANAIS is a project aiming to set up, at the new facilities of the Canfranc Underground Laboratory (Spain),

CONCLUSIONS

• ANAIS-0 results.

ANAIS-0 (old NaI crystal) has been taking data at the LSC to test new PMTs, optimize electronic chain and acquisition protocols, characterize ANAIS background, optimize events selection and design the calibration method.

Best configurations: Ultra low background PMTs and VLB PMTs.

Low energy events selection procedure has been carefully studied and efficiency of the cuts have been estimated.

Background model explains satisfactorily background measurements.

• ANAIS-25 preliminary results.

2 ultrapure NaI(Tl) crystals from Alpha spectra (12.5 kg each) being tested at the LSC.

Outstanding light collection.

Potassium content of 41.7 3.7 ppb.

Alphas rate too high, possible 210Pb bulk contamination under investigation.

On-going discussion with Alpha Spectra trying to improve the 40K and 210Pb contamination contents of the crystals before deciding to buy the 250kg. Next months will be crucial.

C. Cuesta 22