DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH This product must be installed and serviced by appropriately qualified and/or licenced electrical personnel. Isolate the electrical supply before doing any work on this product. Ensure that the product has been correcfly installed and tested for safe operation before reconnecting the electrical supply. The Locking Bar on Iconic grids must be set to the Closed position to ensure that the mechanism cannot be removed during normal operation. There are no user serviceable parts inside the product. Failure to follow these instructions will result in death or serious injury. 41EPBDWCLM-VW Vertical Grid Horizontal Grid Multi-gang orientation Push-Button Dimmer with ControlLink CAUTION EQUIPMENT DAMAGE HAZARD Install the device according to instructions in this document. Pay attention to the specifications and wiring diagrams related to the installation. Do not use this product for any other purpose than specified in this instruction. Dropping the device may damage the mech. Check device operates after being dropped or if physical damage is shown. Failure to follow these instructions can result in injury or equipment damage. NOTICE EQUIPMENT DAMAGE HAZARD (LOAD AND OPERATION) Operation of Iconic units at elevated temperatures or voltages outside of specification (240 V a.c. and 25 °C) may cause the over-temperature protection circuitry to operate. Operating with significant overload may cause the thermal fuse to blow and render the unit inoperable. Reduce the size of the connected load or use a different brand of lamp to prevent recurrence. Do not operate the product for prolonged periods in extreme conditions. Failure to follow these instructions can result in equipment damage. NOTICE MAXIMUM LOAD RATINGS APPLY Ensure that the number of Low Voltage Lighting Transformers connected to a single LED Push-Button Dimmer does not exceed the maximum load rating of the unit. Failure to follow these instructions can result in equipment damage. 1 2 3 4 Fitting the mechanism to the grid Mounting the grid Wall box depth: min. 70 mm Follow the installation instructions Download the Wiser Room App for your smartphone Connect your smartphone to the dimmer Configure the dimmer and save settings Installing the skin CTL L A N CTL A N CTL A N A N A A A N N N L CTL CTL CTL (Total length max. 50 m) (300 W max.) SMART REMOTE MECHANISM SMART REMOTE MECHANISM L N LOAD PUSH-BUTTON DIMMER Note: All Active connections must be on the same phase. A Active N Neutral L Load CTL ControlLink PE Protective Earth PE PE Notes: Up to 5 way dimming (e.g. 1 dimmer plus up to 4 remote mechanisms, or up to 3 dimmers plus 2 remote mechanisms). In case of multiple dimmers being installed, each dimmer must be connected to a separate load. Total length of ControlLink cable in a circuit must not exceed 50 m. Control and load cables must not be coupled. Cabling and connections (Typical 3-way dimmer installation using Wiser Iconic Push-Button Dimmer + 2 Smart Remote Mechanisms) Multi-gang derating 1 dimmer: max. load = 300 W 2 dimmers: max. load = 225 W per dimmer 3 dimmers: max. load = 150 W per dimmer Note: When installing in a 3 gang plate, the middle mech must face opposite way. Removing the skin For your safety Retrofit (2-way illustration shown) Installation Download the Wiser Room App to connect your smart phone or tablet to Clipsal Iconic BLE mechs. Wiser Room App CTL L A N CTL A N A A BEFORE AFTER A A N N CTL CTL N L L N L ICONIC PUSH-BUTTON DIMMER SMART REMOTE MECHANISM 2-WAY SWITCH LOAD 2-WAY SWITCH SUPPLY RED RED WHITE WHITE TWO-CORE DI L N LOAD N A SUPPLY TWO-CORE DI RE-USE RE-USE Dimmable LED 300 W Non-dimmable LED Not compatible 240 V Incandescent/Halogen 300 W LV halogen with electronic transformer 300 W LV halogen with iron-core transformer 300 W Dimmable compact fluorescent 300 W Non-dimmable compact fluorescent Not compatible Load compatibility

Push-Button Dimmer with ControlLink For your safety

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Push-Button Dimmer with ControlLink For your safety

DANGERHAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH• This product must be installed and serviced by appropriately

qualified and/or licenced electrical personnel. • Isolate the electrical supply before doing any work on this

product. • Ensure that the product has been correcfly installed and tested

for safe operation before reconnecting the electrical supply. • The Locking Bar on Iconic grids must be set to the Closed

position to ensure that the mechanism cannot be removed during normal operation.

• There are no user serviceable parts inside the product.

Failure to follow these instructions will result in death or serious injury.

41EPBDWCLM-VW

Vertical Grid Horizontal Grid

Multi-gang orientation

Push-Button Dimmer with ControlLink

CAUTIONEQUIPMENT DAMAGE HAZARD• Install the device according to instructions in this document.• Pay attention to the specifications and wiring diagrams related

to the installation.• Do not use this product for any other purpose than specified in

this instruction.• Dropping the device may damage the mech. Check device

operates after being dropped or if physical damage is shown.

Failure to follow these instructions can result in injury or equipment damage.

NOTICEEQUIPMENT DAMAGE HAZARD (LOAD AND OPERATION)• Operation of Iconic units at elevated temperatures or voltages

outside of specification (240 V a.c. and 25 °C) may cause the over-temperature protection circuitry to operate. Operating with significant overload may cause the thermal fuse to blow and render the unit inoperable.

• Reduce the size of the connected load or use a different brand of lamp to prevent recurrence.

• Do not operate the product for prolonged periods in extreme conditions.

Failure to follow these instructions can result in equipment damage.

NOTICEMAXIMUM LOAD RATINGS APPLYEnsure that the number of Low Voltage Lighting Transformers connected to a single LED Push-Button Dimmer does not exceed the maximum load rating of the unit.

Failure to follow these instructions can result in equipment damage.

1

2

3

4

Fitting the mechanism to the grid

Mounting the grid

Wall box depth:min. 70 mm

Follow the installation instructions

Download the Wiser Room App for your smartphone

Connect your smartphone to the dimmer

Configure the dimmer and save settings

Installing the skin

CTL

L A

N

CTL

A

NCTL

A

N

AN

A

A A

N

N N

L

CTL

CTL

CTL

(Total length max. 50 m)

(300 W max.)

SMARTREMOTE

MECHANISM

SMARTREMOTE

MECHANISM

L N

LOAD

PUSH-BUTTONDIMMER

Note:All Active connections must be on the same phase.

A ActiveN NeutralL LoadCTL ControlLinkPE Protective Earth

PE

PE

Notes:• Up to 5 way dimming (e.g. 1 dimmer plus

up to 4 remote mechanisms, or up to 3 dimmers plus 2 remote mechanisms). In case of multiple dimmers being installed, each dimmer must be connected to a separate load.

• Total length of ControlLink cable in a circuit must not exceed 50 m.

• Control and load cables must not be coupled.

Cabling and connections (Typical 3-way dimmer installation using Wiser Iconic Push-Button Dimmer + 2 Smart Remote Mechanisms)

Multi-gang derating1 dimmer: max. load = 300 W 2 dimmers: max. load = 225 W per dimmer 3 dimmers: max. load = 150 W per dimmer

Note: When installing in a 3 gang plate, the middle mech must face opposite way.

Removing the skin

For your safety

Retrofit (2-way illustration shown)

Installation

Download the Wiser Room App to connect your smart phone or tablet to Clipsal Iconic BLE mechs.

Wiser Room App

CTL

L

A

N

CTL

A

N

AABEFORE

AFTER A

AN

NCTL

CTL

N

L LN

L

ICONICPUSH-BUTTON

DIMMERSMART REMOTE

MECHANISM

2-WAYSWITCH

LOAD2-WAY

SWITCHSUPPLY

RED

RED

WHITE

WHITE

TWO-CORE DI

LN

LOAD

N

A

SUPPLY

TWO-CORE DI

RE-U

SE

RE-U

SE

Dimmable LED 300 W

Non-dimmable LED Not compatible

240 V Incandescent/Halogen 300 W

LV halogen with electronic transformer 300 W

LV halogen with iron-core transformer 300 W

Dimmable compact fluorescent 300 W

Non-dimmable compact fluorescent Not compatible

Load compatibility

Page 2: Push-Button Dimmer with ControlLink For your safety

QGH5281902_03 August 2019

Schneider Electric (Australia) Pty Ltd33 Port Wakefield Road, Gepps Cross SA 5094Customer Care: 13 73 28Email: [email protected]

Customer care

Warranty informationWe warrant this product for 2 years—for details visit: www.schneider-electric.com.au/en/about-us/legal/terms-and-conditions.jsp

Technical data

Note: See product data sheet for full specifications. Specifications typical at 25 °C.

Operating voltage 220–240 V a.c., 50 Hz

Load rating No minimum load required, Max. 300 W

Load connection LED indicator flashes in the event of load disconnection or failure.

Multi-way limits Max. 5-way dimming(Max. 3 Wiser Iconic Push-Button Dimmers + remainder Iconic Remote Mechanisms.)

Multi-way interface ControlLink

ControlLink cable limit Max. 50 m for entire circuit

Dimming range Min. 0%, Max. 100% (depending on load)

Power failure data retention

Internal date/time retained for up to 6 hrs.Settings preserved indefinitely.

Environmental rating IP20 (designed for indoor use only)

Operating humidity 5%–90% RH, non-condensing

Compliance AS/NZS 60669.2.1, AS/NZS CISPR-15

Restoring the dimmer to factory defaults

Short pressdimmer4 timesand hold

Indicatorflashes

red

Release

10 s

Note: All customised dimmer settings and bluetooth pairing information will be lost. Remove the skin before restoring to see the mechanism indicator.Creating an Installer restore point

‘Copy and paste’ settings from another Wiser Iconic dimmerNote: Settings can only be copied from a dimmer of the exact same model.

22 mm

22 mm

34 mm

48 mm

22 mm

24 mm

Adjusting the minimum brightness level

Changing the LED indicator behaviour

Setting a time schedule

Setting/Adjusting the timerNote: When the timer is operating, time schedules are suspended.

Advanced settings > Min / max brightness

Tap this iconfor more information

Advanced settings >

Advanced settings >

LED indicator settings >

Make selection A, then save B(Default setting)

Time schedule > Edit A, + Add new schedule B Make selections C, then save D

(Times)

(Brightness Level)

(Days)

(Months)

+ Add new Schedule

Edit Save

Time schedule >

Timer > Enable the timer A Set time interval B, then save C

Timer enable

Save

Timer >

Enter password A, then Continue B(Note: Password cannot be changed)

Password:

1 2 3 4

Continue

Advanced settings >

Create an installer restore point

When pairing with new dimmer… …or via Advanced settings Select dimmer to copy from A, then copy B

Copy settings from another device

Copy settings from another device >

Copy

Dimmer default settingsThe dimmer can be installed and operated ‘out of the box’ as a dimmer mechanism with no configuration. The dimmer incorporates a Memo function, so after switching OFF the load will return to the previous brightness level switched ON again. Note: At low dim levels a kick-start may occur.

Customising with the Wiser Room AppUse the Wiser Room App to customise the dimmer:• Adjust the minimum brightness level based on the

load requirements• Change the status LED indicator behaviour• Create an Installer restore point to save the settings in case

a future restore is needed (highly recommended)• ‘Copy and paste’ settings from another Wiser Iconic dimmer to save time when

configuring multiple dimmers, such as when installing in an apartment block.You can use the Wiser Room App to set and adjust the timer, and set up to 16 time schedules with configurable dimming levels.

Note: When controlling with the Wiser Room App be in the same room and within a range of 8-10 m of the dimmer. Range can be affected by walls and other structures.

Dimmer settings...

Using the Wiser Room App

Short pressswitch3 times

Start theWiser Room App

on your smartphone,then tap

Edit > + Add new device

BLEpairing mode

started (LED flashesgreen/red)

Follow pairinginstructions in

Wiser Room App

Dimmer andsmartphone

paired

3x

30 s max.

Wiser Room App

Wiser App

Pairing

Settings are now copied to the new dimmer.

Schneider Electric reserves the right to change specifications, modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in these instructions are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein.

© Schneider Electric 2019

This material is copyright under Australian and international laws. Except as permitted under the relevant law, no part of this work may be reproduced by any process without prior written permission of and acknowledgment to Schneider Electric.

Android is a trademark of Google LLC.

Apple is a trademark of Apple Inc., registered in the U.S. and other countries.