Solar Charge Con troller
User Manual
AEH-SCC02-3ASolar Charge Con troller with USB - 3A
All rights reservedSpecifications subject to change without prior notice
2
3
This user manual applies to the following product:
Product Reference Number Description Product
AEH-SCC02-3A Solar Charge Controller - 3A with USB
4
IMPORTANT NOTES
How to use this ManualThis manual explains how to install and operate Solar ChargeController - 3A.
Product Safety
• This product must not be used under inflammable environment.• The room where the Solar Charge Controller and the loads are
installed must be well ventilated.• Only qualified technicians must install or uninstall the Solar Charge
Controller.
with USB
5
CONTENTS
INTRODUCTION……………………………………………….… 6
PACKAGE CONTENTS……………………………….….….….. 7
PARTS IDENTIFICATION…………………………….……..….. 8
TECHNICAL SPECIFICATIONS………………........…………. 9
INSTALLATION PROCEDURE…………………..…….…..…..10
OPERATION PROCEDURE…………………….…….………. 14
TROUBLESHOOTING............…………….…………….……..15
WARRANTY TERMS AND CONDITIONS…………...............17
WARRANTY CARD……………………………………………...18
CUSTOMER CARE CENTRE....……………………………….19
6
Dear Customer,
Thank you for purchasing the Schneider Electric We are confident that you will find satisfaction in
the performance, quality and the functional beauty achieved through our human engineering concept. Please read and understand the manual carefully before use, for better performance of the Solar Charge Controller.
INTRODUCTION
is a highly reliable device used to charge thebattery from the solar panel efficiently and provide power to the connected loads with following protections:
• Inbuilt reverse polarity protection for battery input terminal and solar input terminal.
• Over current and short circuit protection. • Battery protection against overcharge and over discharge.• Input surge protection.
has three output ports. Two output terminals to connect 12V DC Loads (Max 36W) and one universal mobile charging port.
Solar ChargeController - 3A.
Solar Charge Controller - 3A
Solar Charge Controller - 3A
with USB
with USB
with USB
7
PACKAGE CONTENTS
Solar Charge Controller - 3Awith USB
2 Nos. of screws of 3.5mm x 19mm for mountingthe on the wallSolar Charge Controller
2DC plug to connect the 2.5 mm cable from the battery to the battery input terminal of the Solar Charge Controller
3 Nos. of fuse, each fuse rating 5A
Cable with USB mobile charging port to connect to the mobile charging output of the Solar Charge Controller
8
Solar Input
Fuse
PARTS IDENTIFICATION
Output 1
Output 2
Mobile Charging Port
GREEN LED
GREEN LED
YELLOW LED
RED LED
: Battery is Charging
: Battery High
: Battery Low
: Battery Conservation Mode
Battery Input Terminal
TECHNICAL SPECIFICATIONS
INPUT / OUTPUT RATING
Input Voltage
A
17 – 21V
Input Source
Rated output voltage Load 1 • Load 2 • Mobile charging port
•
Maximum rated output current
Rated output power
B INDICATIONS
Battery charging
Battery high
Battery in conservation mode
Battery low
PROTECTION AND MONITORING C
High voltage disconnect
Low voltage disconnect
Reconnect voltage
Battery and solar panel reverse polarity protection
Battery overcharge and over discharge protectionShort circuit protectionOver current protectionLightening surge protection
Supply from Solar Panel 12V, Max 40Wp
12V12V 5.5V
3A continuous load3.9A for 1 hour
36W
GREEN LED on LEFT
GREEN LED on RIGHT
YELLOW LED
RED LED
14.3+/-0.2V
11.6+/- 0.1V
12.7V
YES
YES
YES
YES (fuse 5A)
YES
9
1
2
3
4
5
678
1
2
3
4
5
4
3
2
1
10
Figure 1
2. Connect the Solar Charge Controller to the solar panel Connect the cable from the solar panel to the solar input terminal of the with correct polarity. Solar Charge Controller
Figure 2
After connecting, observe that GREEN LED and YELLOW LED are ON
INSTALLATION PROCEDURE
1. Mount the on the wall Refer to figure 1 to understand how to mount the on the wall.
Solar Charge ControllerSolar Charge Controller
55m
m
+ve -ve
+ve
-ve
11
3. Connect the DC plug to the battery through the cable 2 Connect one end of the 2.5 mm BLACK wire to the –ve input of the DC
plug and other end to the –ve terminal of the battery. Connect one end of 2the 2.5 mm RED wire to the +ve input of the DC plug and other end to
the +ve terminal of the battery as shown in figure 3.
Figure 3
+ve
-ve
4. Connect the battery to the Solar Charge Controller Connect the DC plug to the battery input terminal of the
as shown in figure 4 and figure 5.Solar Charge
Controller
Figure 5
Figure 4
+ve -ve
+ve-ve
-ve
+ve
12
5. Connect the load to the Connect the load to the output terminal of the through a switch as shown in figure 6.
Solar Charge ControllerSolar Charge Controller
Figure 6
6. Connect mobile phone to the mobile charging port Connect your mobile phone to mobile charging port of the
as shown in figure 7.Solar Charge
Controller
Figure 7
+ve
-ve
+ve
-ve
13
7. Overview Refer to the figure 8 showing the circuit diagram, to understand how to connect the solar panel, the battery and the DC loads to the Solar Charge Controller.
Figure 8
Solar Panel12V , Max 40Wp
Solar Charge Controller - 3Awith USB
LED Lamp 12V DC
Switch
Mobile Phone
Battery 12V DC
-ve+ve
+ve-ve
-ve
+ve
+ve
-ve
-ve+ve
+ve
-ve
14
OPERATION PROCEDUREBattery chargingBattery will be automatically charged during the day from the solar panel. Do not disconnect the solar panel from the Solar Charge Controller. The GREEN LED on the left of the Solar Charge Controller will glow when the battery is charging.
Loads are powered through When the loads connected to the output 1 and output 2 of the Solar Charge Controller are switched ON, the battery starts discharging. The loads will automatically switch OFF as the battery voltage drops to 11.6+/-0.1V. The RED LED of the Solar Charge Controller glows and indicates the battery is low. The battery will be charged again from the solar panel when the sun shines again.
Solar Charge Controller
Battery status indication
GREEN LED on LEFTGREEN LED on RIGHTYELLOW LEDRED LED
Battery ChargingBattery High Battery in Conservation modeBattery Low
Mobile phone chargingPlug the cable assembly to the mobile charging port whenever you want to charge your mobile phone.
LED Indication Battery Status
15
TROUBLESHOOTING
Symptom Possible Cause Solution
Loads not powering ON
1. System is not properly connected
Connect the solar panel and the battery through the Solar Charge Controller. Check if thebattery charging GREEN LEDglows. In case GREEN LED does not glow, disconnect and reconnect the system.
2. Loads are connected to the Solar Charge Controller with polarity reversed
3. Battery is connected to the solar charge controller with polarity reversed
To understand how to connect the loads with correct polarity, refer to figure 6. Connect the +ve terminal to the +ve output terminal and –ve terminal to the –ve output terminal of the Solar Charge Controller.
Ensure that the battery is correctly connected. In case the battery is not correctly connected, disconnect the battery. Connect the batterywith correct polarity, i.e. connect red wire and black wire of the battery connectioncable to the +ve terminal and the –ve terminal of the battery.If the battery is reverse connected, the fuse blows. Ensure that the fuse has not blown. In case the fuse has blown, replace the fuse.
16
Symptom Possible Cause Solution
Loads not powering ON
4. Output short circuit while connecting the loads
Ensure that the output is properly connected. In case the connection is not proper, disconnect the system and reconnect the system. Ensure that the fuse has not blown. In case the fuse has blown, replace the fuse.
5. When in the morning, and at night there is no sunshine and the battery is discharged
1.The solar panel is reverse connected
2. Battery is reverse connected
Then the loads may not be powered as there is no sufficient energy. Check if the RED LED glows. Charge the battery until the RED LED stops glowing and the GREEN LED glows to indicate a fully charged battery.
To understand how to connect the solar panel with the correct polarity, refer to figure 2. Connect the +ve wire and –ve wire from the solar panel to the +ve and the –ve solar input terminal of the Solar Charge Controller. Ensure that the fuse is properly connected. In case the fuse has blown, replace the fuse. Disconnect the battery. Now connect the battery with correct polarity.
Battery is not charging
17
WARRANTY TERMS AND CONDITIONS
The purchaser of the enjoys a warranty of 12 months from the date of purchase.
This warranty is valid only for manufacturing defects and does not cover defects due to external damages such as the following:
• Improper operation, maintenance or modifications.• Natural calamities such as fire, flood or other acts of God.• Breakage of plastic components, including the product housing.
This warranty is made void If :
• The warranty void sticker is tampered or removed.• The warranty card is misplaced.• The product is opened and serviced by any person not authorized by
Schneider Electric.
For parts replaced during servicing, only the remaining warranty period of the original product applies.
Solar Charge Controller - 3Awith USB
18
WARRANTY CARD
WARRANTY CARD
Variants
Serial Number
Name of the Dealer/Supplier
Address
Date of Purchase
Dealer's Signature and Stamp
This warranty is valid only if the card is filled in completely, signed andstamped by the dealer on the date of purchase.
AEH-SCC02-3A
19
CUSTOMER CARE CENTRE
In case of any queries related to the product, please contact your local dealer.
990-4721