Upload
vanhanh
View
225
Download
0
Embed Size (px)
Citation preview
TEST REPORT
No. 2014RFW0063
For
Client : Shanghai SIMcom Ltd
Production : WCDMA\EDGE\GPRS\GSM module
XXXX Model Name : SIM5360E
Hardware Version: V1.03
Software Version: SIM5360E_V3.5
Issued date: 2014-05-29
Note:
The test results in this test report relate only to the devices specified in this report. This report shall not
be reproduced except in full without the written approval of ECIT Shanghai.
Test Laboratory:
ECIT Shanghai, East China Institute of Telecommunications
Add: 7-8F, G Area, No.668, Beijing East Road, Huangpu District, Shanghai, P. R. China
Tel: (+86)-021-63843300, E-Mail: [email protected]
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 2 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
Revision Version
Report Number Revision Date Memo
2014RFW0063 00 2014-05-29 Initial creation of test report
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 3 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
CONTENTS
1. TEST LABORATORY ................................................................................................................ 5
1.1. TESTING LOCATION ................................................................................................................ 5
1.2. TESTING ENVIRONMENT ....................................................................................................... 5
1.3. PROJECT DATA ....................................................................................................................... 5
1.4. SIGNATURE .............................................................................................................................. 5
2. CLIENT INFORMATION ............................................................................................................ 6
2.1. APPLICANT INFORMATION .................................................................................................... 6
2.2. MANUFACTURER INFORMATION .......................................................................................... 6
3. EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ............................ 7
3.1. ABOUT EUT .............................................................................................................................. 7
3.2. INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST ....................................... 7
3.3. INTERNAL IDENTIFICATION OF AE USED DURING THE TEST .......................................... 7
4. REFERENCE DOCUMENTS .................................................................................................... 8
4.1. DOCUMENTS SUPPLIED BY APPLICANT ............................................................................. 8
4.2. REFERENCE DOCUMENTS FOR TESTING ........................................................................... 8
5. TEST RESULTS ........................................................................................................................ 9
5.1. SUMMARY OF TEST RESULTS .............................................................................................. 9
5.2. STATEMENTS ........................................................................................................................... 9
6. TEST EQUIPMENTS UTILIZED ............................................................................................. 10
6.1. ME7873F ................................................................................................................................. 10
6.2. RSE TEST SYSTEM ............................................................................................................... 11
6.3. CLIMATE CHAMBER .............................................................................................................. 11
6.4. VIBRATION TABLE ................................................................................................................. 11
7. MEASUREMENT UNCERTAINTY .......................................................................................... 12
ANNEX A. EUT PHOTOGRAPH ................................................................................................ 13
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 4 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
ANNEX B. PICS/PIXIT INFORMATION ...................................................................................... 14
ANNEX C. DETAILED TEST RESULTS ..................................................................................... 15
ANNEX C.1. MAIN TERMS ............................................................................................................ 15
ANNEX C.2. TERMS USED IN CONDITION COLUMN ................................................................ 15
ANNEX C.3. TERMS USED IN VERDICT COLUMN .................................................................... 15
ANNEX C.4. TERMS USED IN NOTE COLUMN .......................................................................... 15
ANNEX C.5. TESTCASES LIST .................................................................................................... 16
ANNEX D. CONDUCTED MAXIMUM OUTPUT POWER .......................................................... 21
ANNEX E. CONTROL AND MONITORING FUNCTIONS (UE) PLOT ...................................... 22
ANNEX F. SPURIOUS EMISSIONS RESULTS ......................................................................... 23
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 5 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
1. Test Laboratory
1.1. Testing Location
Company Name: ECIT Shanghai, East China Institute of Telecommunications
Address: 7-8F, G Area,No. 668, Beijing East Road, Huangpu District,
Shanghai, P. R. China
Postal Code: 200001
Telephone: (+86)-021-63843300
Fax: (+86)-021-63843301
1.2. Testing Environment
Normal Temperature: 15-35℃
Relative Humidity: 20-75%
1.3. Project Data
Project Leader: Gong Yujuan
Testing Start Date: 2014-04-21
Testing End Date: 2014-05-22
1.4. Signature
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 6 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
2. Client Information
2.1. Applicant Information
Company Name: Shanghai SIMcom Ltd
Address: Building A, SIM Technology Building,No.633 Jinzhong Road,
Changning District,Shanghai, P.R .China
Telephone: +86 21 32523134
Postcode: 200235
2.2. Manufacturer Information
Company Name: Shanghai SIMcom Ltd
Address: Building A, SIM Technology Building,No.633 Jinzhong Road,
Changning District,Shanghai, P.R .China
Telephone: +86 21 32523134
Postcode: 200235
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 7 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
3. Equipment Under Test (EUT) and Ancillary Equipment (AE)
3.1. About EUT
EUT Description WCDMA\EDGE\GPRS\GSM module
Model name SIM5360E
UMTS Frequency Band FDDI/FDDVIII
GSM Frequency Band GSM900/GSM1800/GSM1900/GSM850
E-UTRA Frequency Band NA
Type of modulation QPSK/GMSK
Power Class GSM900:4, DCS1800:1,PCS1900:1
UMTS FDD I :3 ; FDDVIII :3
GPRS Multislot Class 12
EGPRS Multislot Class 12
Extreme Temperature -10/+55℃
Nominal Voltage 3.8V
Extreme High Voltage 4.2V
Extreme Low Voltage 3.4V
Note: Photographs of EUT are shown in ANNEX A of this test report.
3.2. Internal Identification of EUT used during the test
EUT ID* SN or IMEI HW Version SW Version Date of receipt
N03 NA V1.03 SIM5360E_V3.5 2013-04-18
*EUT ID: is used to identify the test sample in the lab internally.
3.3. Internal Identification of AE used during the test
AE ID* Description SN
AE1 RF cable ---
AE2 Dummy Battery ---
*AE ID: is used to identify the test sample in the lab internally.
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 8 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
4. Reference Documents
4.1. Documents supplied by applicant
PICS/PIXIT, referring to Annex B for detailed information, is supplied by the client or manufacturer,
which is the basis of testing.
4.2. Reference Documents for testing
The following documents listed in this section are referred for testing.
Reference Title Version
3GPP TS 34.121-1 3rd Generation Partnership Project; Technical Specification
Group Radio Access Network; Terminal conformance
specification; Radio transmission and reception (FDD)
V11.3.0
3GPP TS 34.121-2 3rd Generation Partnership Project; Technical Specification
Group Radio Access Network User Equipment (UE)
conformance specification; Radio transmission and reception
(FDD); Part 2: Implementation Conformance Statement (ICS)
V11.2.0
ETSI EN 301 908-1 Electromagnetic compatibility and Radio spectrum Matters
(ERM);Base Stations (BS), Repeaters and User Equipment
(UE) for IMT-2000 Third-Generation cellular networks;Part 1:
Harmonized EN for IMT-2000, introduction and common
requirements, covering essential requirements of article 3.2 of
the R&TTE Directive
V5.2.1
ETSI EN 301 908-2 Electromagnetic compatibility and Radio spectrum Matters
(ERM);Base Stations (BS), Repeaters and User Equipment
(UE) for IMT-2000 Third-Generation cellular networks;Part 1:
Harmonized EN for IMT-2000, introduction and common
requirements, covering essential requirements of article 3.2 of
the R&TTE Directive
V5.2.1
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 9 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
5. Test Results
5.1. Summary of Test Results
Note: please refer to Annex C in this test report for the detailed test results.
The following terms are used in the above table.
Pass Amount of test cases with pass results in the given frequency band.
Fail Amount of test cases with fail results in the given frequency band.
Inc Amount of test cases with ambiguous results in the given frequency band.
BR Amount of test cases with pass result for the initial model.
Declare Amount of test cases with conformity declaration from the client in the
given frequency band.
5.2. Statements
The SIM5360E, supporting UMTS/GPRS/GSM/, manufactured by Shanghai SIMcom Ltd., is a
new product for testing
ECIT has verified that the compliance of the tested device specified in section 3 of this test report
is successfully evaluated according to the procedure and test methods as defined in type
certification requirement listed in section 4 of this test report.
WCDMA Band I WCDMA Band VIII
Pass 38 38
Fail 0 0
Inc 0 0
Declare
BR
0 0
0 0
total 38 38
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 10 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
6. Test Equipments Utilized
6.1. ME7873F
TP57-Anritsu ME7873F-WCDMA/RRM/HSDPA
Hardware
No. Name Type SN Qty Manufacture Cal.Due
Date
1 Digital Mobile Radio Transmitter Tester
MS8609A 6200445481 1 Anritsu 2015-1-04
2 W-CDMA Signalling
Tester MD8480C 6200621380 1 Anritsu 2015-1-04
3 RF Switch Driver Unit MN7451A 6200456199 1 Anritsu 2015-1-04
4 RF Switch Driver Unit ME7416B 6200457273 1 Anritsu 2015-1-04
5 RF Interface Unit MN7462A 6200454939 1 Anritsu 2015-1-04
6 Filter Unit for 882/837MHz
MN7464A2 6200454943 1 Anritsu 2015-1-04
7 Filter Unit for
1960/1880MHz MN7464B1 6200454944 1 Anritsu 2015-1-04
8 Filter Unit for 941/896MHz
MN7464A3 6200761912 1 Anritsu 2015-1-04
9 Filter Unit for
2140/1950MHz MN7464A 6200454942 1 Anritsu 2015-1-04
10 RF Combiner Unit MN7463A 6200454941 1 Anritsu 2015-1-04
11 RF Switch Unit MN7465A 6200673887 1 Anritsu 2015-1-04
12 Filter Unit for
2140/1950MHz MN7464A 6200454942 1 Anritsu 2015-1-04
13 Vector Signal
Generator MG3700A 6200666173 1 Anritsu 2015-1-04
14 Vector Signal
Generator MG3700A 6200981903 1 Anritsu 2015-1-04
15 Bit Error Rate Tester MP8931A 6200453582 1 Anritsu 2015-1-04
16 Signal Generator MG3692B 052401 1 Anritsu 2015-1-04
17 RF Interface Unit for
Diversity MN7484A 6200860961 1 Anritsu 2015-1-04
18 Fading Simulator MF6900A 6200989892 1 Anritsu 2015-1-04
19 DC Power Supply 66311B MY4300466
7 1 Agilent 2015-1-04
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 11 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
6.2. RSE Test System
RSE test system
Hardware
No. Name Type SN Qty Manufacture Cal.Due
Date
1 EMI test receiver ESU40 100307 1 Rohde & Schwarz
2014-10-29
2 Trilog super
broadband test antenna
SWB-VULB9163
19-162515 1 SCHWARZBE
CK 2014-11-11
3 Double ridged guide antenna
ETS-3117 135885 1 ETS-LINDGRE
N 2015-04-27
4 Universal Radio Communication
tester CMU200 123102 1
Rohde & Schwarz
2014-08-30
6.3. Climate Chamber
Climate Chamber
No. Name Type SN Qty Manufacture Cal.Due
Date
1 Climate Chamber SH641 92012010 1 ESPEC 2014-6-2
6.4. Vibration table
Viberation table
No. Name Type SN Qty Manufacture Cal.Due
Date
1 vibration table ESS-050 D1205143 1 Dongling 2014-8-11
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 12 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
7. Measurement Uncertainty
Measurement uncertainty for all the testing in this report are within the limit specified in 3GPP TS
34.121-1 Annex 5 .The detailed measurement uncertainty is defined in ECIT documents.
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 13 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
ANNEX A. EUT photograph
Pic A-1 Mobile Phone
Pic A-2 Mobile Phone
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 14 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
ANNEX B. PICS/PIXIT information
Item Release FDD (DS) RF Baseline
Implementation Capabilities Suppport
Allowed
Value Comments
1 R99 Chip rate 3,84 Mcps yes Yes/No
2 R99 Frequency band: 1 920-1 980, 2
110-2 170 MHz yes Yes/No Band I
3 R99 Frequency band: 1 850-1 910, 1
930-1 990 MHz no Yes/No Band II
9 R99 UE Power Class 1 (+33 dBm) no Yes/No
10 R99 UE Power Class 2 (+27 dBm) no Yes/No
11 R99 UE Power Class 3 (+24 dBm) yes Yes/No
12 R99 UE Power Class 4 (+21 dBm) no Yes/No
14 R99 Frequency band: 1710-1785,
1805-1880 MHz no Yes/No Band III
15 R99 Frequency band: 1710-1755,
2110-2155 MHz no Yes/No Band IV
16 R99 Frequency band: 824 – 849,
869-894 MHz no Yes/No Band V
17 R99 Frequency band: 830-840,
875-885 MHz no Yes/No Band VI
18 R99 Frequency band: 2500-2570,
2620-2690 MHz no Yes/No Band VII
19 R99 Frequency band: 880-915,
925-960 MHz yes Yes/No Band VIII
20 R99 Frequency band: 1749.9-1784.9,
1844.9-1879.9 MHz no Yes/No Band IX
21 R99 Frequency band: 1710 - 1770,
2110 - 2170 MHz no Yes/No Band X
22 R99 Frequency band: 1427.9
-1452.9, 1475.9 -1500.9 MHz no Yes/No Band XI
23 R99 Frequency band: 698 – 716, 728
– 746 MHz no Yes/No Band XII
24 R99 Frequency band: 777 – 787, 746
– 756 MHz no Yes/No Band XIII
25 R99 Frequency band: 788 – 798,
758 – 768 MHz no Yes/No Band XIV
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 15 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
ANNEX C. Detailed Test Results
Annex C.1. Main Terms
Verdict Verdict of each test cases.
Test cases Test cases identification number and description in 3GPP test specification and
ETSI specification.
Annex C.2. Terms used in Condition column
NTC Normal voltage, Normal Temperature
HV High voltage, Normal Temperature
LV Low voltage, Normal Temperature
HTHV High voltage, High Temperature
LTHV High voltage, Low Temperature
HTLV Low voltage, High Temperature
LTLV Low voltage, Low Temperature
Vib Vibration
Annex C.3. Terms used in Verdict column
Pass This test cases has been tested, and EUT is conformant to the applied standards
in the given frequency band.
Fail This test cases has been tested, but EUT is not conformant to the applied
standards in the given frequency band.
N/A This test case is either not required/not applicable in the specified band or is not
applicable according to the specific PICS/PIXIT for the EUT.
Inc Test case result is ambiguous in the given frequency band.
Decl Declaration is received from the client to demonstrate the conformity to the
relevant specification in the given frequency band.
BR This test cases is not tested in the given frequency band, but this testcases was
tested with pass result for the initial model in the given frequency band.
Annex C.4. Terms used in Note column
EUT ID EUT ID (e.g N01, N02…..) is used to identify the EUT tested used for each test
cases as specified in section 3 of this test report.
Lab Code Lab code is used to identify the subcontracted lab if this test cases is performed
in the subcontracted lab.
Subcontracted test lab code: N/A
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 16 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
Annex C.5. Testcases list
Testcases Description conditio
n
FDD I FDDVIII
verdict EUT verdict EUT
5.3.1 Radiated emissions (UE) NTC Pass N03 Pass N03
5.3.3 Control and monitoring functions
(UE) NTC Pass N03 Pass N03
ETSI EN 301 908-2
Testcases
in 3GPP
TS 34.121
Testcases
in ETSI
EN
301 908-2
Description condition
FDD I FDD VIII
verdict EUT verdict EUT
5.2 5.3.1
Transmitter
Characteristics /
Maximum Output Power
NTC Pass N03 Pass N03
5.2 5.3.1
Transmitter
Characteristics /
Maximum Output Power
HTHV Pass N03 Pass N03
5.2 5.3.1
Transmitter
Characteristics /
Maximum Output Power
HTLV Pass N03 Pass N03
5.2 5.3.1
Transmitter
Characteristics /
Maximum Output Power
LTHV Pass N03 Pass N03
5.2 5.3.1
Transmitter
Characteristics /
Maximum Output Power
LTLV Pass N03 Pass N03
5.4.3 5.3.4
Transmitter
Characteristics / Output
Power Dynamics in the
Uplink/ Minimum Output
Power
NTC Pass N03 Pass N03
5.4.3 5.3.4
Transmitter
Characteristics / Output
Power Dynamics in the
Uplink/ Minimum Output
Power
HTHV Pass N03 Pass N03
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 17 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
Testcases
in 3GPP
TS 34.121
Testcases
in ETSI
EN
301 908-2
Description condition
FDD I FDD VIII
verdict EUT verdict EUT
5.4.3 5.3.4
Transmitter
Characteristics / Output
Power Dynamics in the
Uplink/ Minimum Output
Power
HTLV Pass N03 Pass N03
5.4.3 5.3.4
Transmitter
Characteristics / Output
Power Dynamics in the
Uplink/ Minimum Output
Power
LTHV Pass N03 Pass N03
5.4.3 5.3.4
Transmitter
Characteristics / Output
Power Dynamics in the
Uplink/ Minimum Output
Power
LTLV Pass N03 Pass N03
5.4.4 5.3.10
Transmitter
Characteristics / Output
Power Dynamics in the
Uplink/
Out-of-synchronisation
Handling of Output
Power
NTC Pass N03 Pass N03
5.9 5.3.2
Transmitter
Characteristics /
Spectrum Emission
Mask
NTC Pass N03 Pass N03
5.10 5.3.11
Transmitter
Characteristics /
Adjacent Channel
Leakage Power Ratio
(ACLR)
NTC Pass N03 Pass N03
5.10 5.3.11
Transmitter
Characteristics /
Adjacent Channel
Leakage Power Ratio
(ACLR)
HTHV Pass N03 Pass N03
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 18 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
Testcases
in 3GPP
TS 34.121
Testcases
in ETSI
EN
301 908-2
Description condition
FDD I FDD VIII
verdict EUT verdict EUT
5.10 5.3.11
Transmitter
Characteristics /
Adjacent Channel
Leakage Power Ratio
(ACLR)
HTLV Pass N03 Pass N03
5.10 5.3.11
Transmitter
Characteristics /
Adjacent Channel
Leakage Power Ratio
(ACLR)
LTHV Pass N03 Pass N03
5.10 5.3.11
Transmitter
Characteristics /
Adjacent Channel
Leakage Power Ratio
(ACLR)
LTLV Pass N03 Pass N03
5.11 5.3.3
Transmitter
Characteristics /
Spurious Emissions
NTC Pass N03 Pass N03
6.4A 5.3.5
Receiver Characteristics
/ Adjacent Channel
Selectivity (ACS)
NTC Pass N03 Pass N03
6.5 5.3.6
Receiver Characteristics
/ Blocking
Characteristics
In band Pass N03 Pass N03
6.5 5.3.6
Receiver Characteristics
/ Blocking
Characteristics
Out Band Pass N03 Pass N03
6.6 5.3.7 Receiver Characteristics
/ Spurious Response NTC Pass N03 Pass N03
6.7 5.3.8
Receiver Characteristics
/ Intermodulation
Characteristics
NTC Pass N03 Pass N03
6.8 5.3.9 Receiver Characteristics
/ Spurious Emissions NTC Pass N03 Pass N03
5.9A 5.3.2
Spectrum Emission
Mask with
HS-DPCCH(Release 5
and later releases)
NTC Pass N03 Pass N03
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 19 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
Testcases
in 3GPP
TS 34.121
Testcases
in ETSI
EN
301 908-2
Description condition
FDD I FDD VIII
verdict EUT verdict EUT
5.10A 5.3.11
Adjacent Channel
Leakage Power Ratio
(ACLR) with
HS-DPCCH(Release 5
and later releases)
NTC Pass N03 Pass N03
5.10A 5.3.11
Adjacent Channel
Leakage Power Ratio
(ACLR) with
HS-DPCCH(Release 5
and later releases)
HTHV Pass N03 Pass N03
5.10A 5.3.11
Adjacent Channel
Leakage Power Ratio
(ACLR) with
HS-DPCCH(Release 5
and later releases)
HTLV Pass N03 Pass N03
5.10A 5.3.11
Adjacent Channel
Leakage Power Ratio
(ACLR) with
HS-DPCCH(Release 5
and later releases)
LTHV Pass N03 Pass N03
5.10A 5.3.11
Adjacent Channel
Leakage Power Ratio
(ACLR) with
HS-DPCCH(Release 5
and later releases)
LTLV Pass N03 Pass N03
5.9B 5.3.2
Spectrum Emission
Mask with
E-DCH( Release 6 and
later releases)
NTC Pass N03 Pass N03
5.10B 5.3.11
Adjacent Channel
Leakage Power Ratio
(ACLR) with
E-DCH(Release 6 and
later releases)
NTC Pass N03 Pass N03
5.10B 5.3.11
Adjacent Channel
Leakage Power Ratio
(ACLR) with
E-DCH(Release 6 and
later releases)
HTHV Pass N03 Pass N03
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 20 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
Testcases
in 3GPP
TS 34.121
Testcases
in ETSI
EN
301 908-2
Description condition
FDD I FDD VIII
verdict EUT verdict EUT
5.10B 5.3.11
Adjacent Channel
Leakage Power Ratio
(ACLR) with
E-DCH(Release 6 and
later releases)
HTLV Pass N03 Pass N03
5.10B 5.3.11
Adjacent Channel
Leakage Power Ratio
(ACLR) with
E-DCH(Release 6 and
later releases)
LTHV Pass N03 Pass N03
5.10B 5.3.11
Adjacent Channel
Leakage Power Ratio
(ACLR) with
E-DCH(Release 6 and
later releases)
LTLV Pass N03 Pass N03
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 21 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
ANNEX D. Conducted Maximum Output Power
Type BandI (dBm) BandVIII (dBm)
WCDMA(RMC 12.2k) 22.46 22.72
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 22 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
ANNEX E. Control and monitoring functions (UE) plot
Fig E-1 Band I plot
Fig E-2 Band VIII plot
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 23 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
ANNEX F. Spurious emissions results
Fig1 Radiated Spurious emissions (FDDI, Horizontal/Vertical , Idle mode, Normal voltage)
Fig2 Radiated Spurious emissions (FDDI, Horizontal/Vertical, Traffic mode, Normal voltage)
-1 1 0
-1 0 0
-9 0
-8 0
-7 0
-6 0
-5 0
-4 0
-3 0
-2 0
-1 0
3 0 M 5 06 0 8 01 0 0 M 2 0 0 3 0 04 0 05 0 0 8 0 01 G 2 G 3 G 4 G5 G6 8 1 2 .7 5 G
Level in
dB
m
F re q u e n c y in H z
3 G P P U M T S ID L E
-1 0 4
-1 0 0
-9 0
-8 0
-7 0
-6 0
-5 0
-4 0
-3 0
-2 4
3 0 M 5 06 0 8 01 0 0 M 2 0 0 3 0 04 0 05 0 0 8 0 01 G 2 G 3 G 4 G5 G6 8 1 2 .7 5 G
Level in
dB
m
F re q u e n c y in H z
3 G P P U M T S T X
RF Test Report Report No.: 2014RFW0063
East China Institute of Telecommunications Page Number : 24 of 25 TEL: +86 21 63843300 FAX: +86 21 63843301 Report Issued Date : May 29, 2014
Fig3 Radiated Spurious emissions (FDDVIII, Horizontal/Vertical, Idle mode, Normal voltage)
Fig4 Radiated Spurious emissions (FDDVIII, Horizontal/Vertical , Traffic mode, Normal voltage)
**********End The Report**********
-1 0 0
-9 0
-8 0
-7 0
-6 0
-5 0
-4 0
-3 0
-2 0
-1 0
0
3 0 M 5 06 0 8 01 0 0 M 2 0 0 3 0 04 0 05 0 0 8 0 01 G 2 G 3 G 4 G5 G6 8 1 2 .7 5 G
Level in
dB
m
F re q u e n c y in H z
3 G P P U M T S ID L E
-1 1 0
-1 0 0
-9 0
-8 0
-7 0
-6 0
-5 0
-4 0
-3 0
-2 0
-1 0
3 0 M 5 06 0 8 01 0 0 M 2 0 0 3 0 04 0 05 0 0 8 0 01 G 2 G 3 G 4 G5 G6 8 1 2 .7 5 G
Level in
dB
m
F re q u e n c y in H z
3 G P P U M T S T X