Upload
others
View
7
Download
0
Embed Size (px)
Citation preview
EN 300 440 Test Report
Product Name : Wireless Module
Model No. : SIM5320E
Applicant : Shanghai Simcom Ltd.
Address : Building A, SIM Technology Building, No. 633, Jinzhong
Road, Changning Disdrict, Shanghai P.R. China 200335
Date of Receipt : 08/06/2011
Test Date : 08/06/2011~16/06/2011
Issued Date : 16/06/2011
Report No. : 112S010R-RF-CE-P14V02
Report Version : V1.0
The test results relate only to the samples tested.The test results shown in the test report are traceable to the national/international standard through the calibration of the equipment and evaluated measurement uncertainty herein. This report must not be used to claim product endorsement by TAF, NVLAP or any agency of the Government. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation.
Report No: 112S010R-RF-CE-P14V02
Page: 2 of 30
Test Report Cert i f icat ion Issued Date : 16/06/2011 Report No. : 112S010R-RF-CE-P14V02
Product Name : Wireless Module
Applicant : Shanghai Simcom Ltd.
Address : Building A, SIM Technology Building, No. 633, Jinzhong
Road, Changning Disdrict, Shanghai P.R. China 200335
Manufacturer : Shanghai Simcom Ltd.
Address : Building A, SIM Technology Building, No. 633, Jinzhong
Road, Changning Disdrict, Shanghai P.R. China 200335
Model No. : SIM5320E
EUT Voltage : 3.7V/3.4V/4.2V
Brand Name : SIMCom
Applicable Standard : ETSI EN 300 440-1 V1.6.1 (2010-08)
ETSI EN 300 440-2 V1.4.1 (2010-08)
Test Result : Complied
Performed Location : Suzhou EMC Laboratory
No.99 Hongye Rd., Suzhou Industrial Park Loufeng
Hi-Tech Development Zone., Suzhou, China
TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
Documented By :
(Engineering ADM: Alice Ni)
Reviewed By :
(Senior Engineer: Robin Wu)
Approved By :
(Engineering Supervisor: Marlin Chen)
Report No: 112S010R-RF-CE-P14V02
Page: 3 of 30
Laboratory Information
We, QuieTek Corporation, are an independent EMC and safety consultancy that was established the whole facility in our laboratories. The test facility has been accredited/accepted(audited or listed) by the following related bodies in compliance with ISO 17025, EN 45001 and specified testing scope:
The related certificate for our laboratories about the test site and management system can be downloaded from QuieTek Corporation’s Web Site : http://www.quietek.com/tw/ctg/cts/accreditations.htm The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site : http://www.quietek.com/ If you have any comments, Please don’t hesitate to contact us. Our contact information is as below: HsinChu Testing Laboratory : No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C. TEL:+886-3-592-8858 / FAX:+886-3-592-8859 E-Mail : [email protected]
LinKou Testing Laboratory : No. 5-22, Ruei-Shu Valley, Ruei-Ping Tsuen, Lin-Kou Shiang, Taipei, Taiwan, R.O.C. TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : [email protected]
Suzhou (China) Testing Laboratory : No. 99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-Tech Development Zone., Suzhou,China. TEL : +86-512-6251-5088 / FAX : +86-512-6251-5098 E-Mail : [email protected]
Taiwan R.O.C. : BSMI, NCC, TAF
Germany : TUV Rheinland
Norway : Nemko, DNV
USA : FCC, NVLAP
Japan : VCCI
Report No: 112S010R-RF-CE-P14V02
Page: 4 of 30
TABLE OF CONTENTS Description Page 1. General Information........................................................................................................6 1.1. EUT Description ..............................................................................................6 1.2. Mode of Operation...........................................................................................7 1.3. Tested System Details .....................................................................................8 1.4. Configuration of Tested System.......................................................................9 1.5. EUT Exercise Software....................................................................................9 2. Technical Test ............................................................................................................... 11 2.1. Summary of Test Result................................................................................. 11 2.2. Measurement Uncertainty..............................................................................12 2.3. Test Environment...........................................................................................13 3. Equivalent Isotropic Radiated Power (EIRP) ................................................................14 3.1. Test Equipment..............................................................................................14 3.2. Test Setup .....................................................................................................15 3.3. Limit...............................................................................................................16 3.4. Test Procedure ..............................................................................................16 3.5. Test Result.....................................................................................................16 4. Permitted Range of Operating Frequencies .................................................................17 4.1. Test Equipment..............................................................................................17 4.2. Test Setup .....................................................................................................17 4.3. Limit...............................................................................................................17 4.4. Test Procedure ..............................................................................................18 4.5. Test Result.....................................................................................................18 5. Transmitter Spurious Emissions ...................................................................................19 5.1. Test Equipment..............................................................................................19 5.2. Test Setup .....................................................................................................20 5.3. Limit...............................................................................................................21 5.4. Test Procedure ..............................................................................................21 5.5. Test Result.....................................................................................................21 6. Receiver Spurious Emissions .......................................................................................22 6.1. Test Equipment..............................................................................................22 6.2. Test Setup .....................................................................................................23 6.3. Limit...............................................................................................................24 6.4. Test Procedure ..............................................................................................24 6.5. Test Result.....................................................................................................25 6.6. Test Photograph ............................................................................................25 7. Duty Cycle ....................................................................................................................27 7.1. Test Equipment..............................................................................................27
Report No: 112S010R-RF-CE-P14V02
Page: 5 of 30
7.2. Test Setup .....................................................................................................27 7.3. Limit...............................................................................................................28 7.4. Test Procedure ..............................................................................................28 7.5. Test Result.....................................................................................................28 8. Attachment ...................................................................................................................29 EUT Photograph............................................................................................29
Report No: 112S010R-RF-CE-P14V02
Page: 6 of 30
1. General Information 1.1. EUT Description
Product Name Wireless Module
Brand Name SIMCom
Model No. SIM5320E
Working Voltage 3.7V/3.4V/4.2V
GPS Function YES
Tx Frequency Range GSM900: 880MHz to 915MHz DCS1800: 1710MHz to 1785MHz WCDMA: 1920MHz to 1980MHz (Band I)
Rx Frequency Range GSM900: 925MHz to 960MHz DCS1800: 1805MHz to 1880MHz WCDMA: 2110MHz to 2170MHz (Band I)
Channel Number GSM900: 173 DCS1800: 373 WCDMA: 277
Type of Modulation GMSK for GSM&GPRS 8PSK for EDGE QPSK for WCDMA
Channel Control Auto
Report No: 112S010R-RF-CE-P14V02
Page: 7 of 30
1.2. Mode of Operation QuieTek has verified the construction and function in typical operation. All the test modes were carried out with the EUT in normal operation, which was shown in this test report and defined as: Test Mode
Mode 1: GPS Receive
Report No: 112S010R-RF-CE-P14V02
Page: 8 of 30
1.3. Tested System Details The types for all equipments, plus descriptions of all cables used in the tested system (including inserted cards) are:
Product Manufacturer Model No. Serial No. Power Cord
1 SG Agilent E4438C N/A N/A
Report No: 112S010R-RF-CE-P14V02
Page: 9 of 30
1.4. Configuration of Tested System
Connection Diagram
Signal Cable Type Signal cable Description
A Coaxial Cable Shielded, >5m
EUT A
1
Report No: 112S010R-RF-CE-P14V02
Page: 10 of 30
1.5. EUT Exercise Software
1 Setup the EUT and simulators as shown on above.
2 Turn on the power of equipment.
3 Make the EUT work under the “GPS” Mode.
4 Turn to Test.
Report No: 112S010R-RF-CE-P14V02
Page: 11 of 30
2. Technical Test 2.1. Summary of Test Result
No deviations from the test standards Deviations from the test standards as below description:
Performed Test Item Normative References Test
Performed Deviation
Equivalent Isotropic Radiated
Power (EIRP)
ETSI EN 300 440-1 V1.6.1 (2010-08) N/A N/A
Permitted Range of Operating
Frequencies
ETSI EN 300 440-1 V1.6.1 (2010-08) N/A N/A
Transmitter Spurious Emissions ETSI EN 300 440-1 V1.6.1 (2010-08) N/A N/A
Receiver Spurious Emissions ETSI EN 300 440-1 V1.6.1 (2010-08) Yes No
Duty Cycle ETSI EN 300 440-1 V1.6.1 (2010-08) N/A N/A
Report No: 112S010R-RF-CE-P14V02
Page: 12 of 30
2.2. Measurement Uncertainty Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the apparatus:
Parameter Uncertainty
RF Frequency ±1 x 10-7
RF Power (Conducted) ±0.7dB
Radiated Emission of Transmitter, Valid to 80 GHz
±5.2dB
Radiated Emission of Receiver, Valid to 80 GHz
±5.2dB
Temperature ±0.5℃
Humidity ±1%
Report No: 112S010R-RF-CE-P14V02
Page: 13 of 30
2.3. Test Environment
Items Required (IEC 68-1) Actual
Temperature (°C) 15-35 21
Humidity (%RH) 25-75 50
Barometric pressure (mbar) 860-1060 950-1000
Report No: 112S010R-RF-CE-P14V02
Page: 14 of 30
3. Equivalent Isotropic Radiated Power (EIRP)
3.1. Test Equipment Equivalent Isotropic Radiated Power (EIRP) / TR-8
Instrument Manufacturer Type No. Serial No. Cal. Due Date
Power Meter Anritsu ML2495A 0905006 2012/01/12
Power Sensor Anritsu MA2411B 0846014 2012/01/12
DC Power Supply IDRC CD-035-020PR 977272 2011/10/21
Programmable
Temperature &
Humidity Chamber
Gaoyu TH-1P-B WIT-05121302 2012/01/19
Temperature/Humidity
Meter Zhicheng ZC1-2 TR8-TH 2012/05/04
Note: All equipments are calibrated with traceable calibrations. Each calibration is traceable to the national
or international standards.
Report No: 112S010R-RF-CE-P14V02
Page: 15 of 30
3.2. Test Setup For Conducted Measurement
Power Meter
12dBm
Temperature Chamber
Power Supply
Report No: 112S010R-RF-CE-P14V02
Page: 16 of 30
3.3. Limit
Maximum radiated peak power (e.i.r.p.) Frequency Bands Power Application Notes
2400MHz to 2483.5MHz 10 mW e.i.r.p. Generic use
2400MHz to 2483.5MHz 25 mW e.i.r.p. Detection, movement and alert
applications
(a) 2466MHz to 2454MHz 500 mW e.i.r.p. RFID See also table 7 and annex C
(b) 2466MHz to 2454MHz 4 W e.i.r.p. RFID See also table 7 and annex C
5725MHz to 5875MHz 25 mW e.i.r.p. Generic use
9200MHz to 9500MHz 25 mW e.i.r.p. Detection, movement and alert
applications
9500MHz to 9975MHz 25 mW e.i.r.p. Detection, movement and alert
applications
10.5GHz to 10.6GHz 25 mW e.i.r.p. Detection, movement and alert
applications
13.4GHz to 14.0GHz 25 mW e.i.r.p. Detection, movement and alert
applications
17.1GHz to 17.3GHz 400 mW e.i.r.p. GBSAR detection, movement and
alert applications
See annex E
24.00GHz to 24.25GHz 100 mW e.i.r.p Generic use and detection,
movement and alert application
3.4. Test Procedure
Refer to ETSI EN 300 440-1 V1.6.1 (2010-08) Clause 7.1
3.5. Test Result
It is not suitable to perform this test item.
Report No: 112S010R-RF-CE-P14V02
Page: 17 of 30
4. Permitted Range of Operating Frequencies
4.1. Test Equipment Permitted Range of Operating Frequencies / TR-8
Instrument Manufacturer Type No. Serial No. Cal. Due Date
Spectrum Analyzer Agilent E4446A MY45300103 2012/04/30
DC Power Supply IDRC CD-035-020PR 977272 2011/10/21
Programmable
Temperature &
Humidity Chamber
Gaoyu TH-1P-B WIT-05121302 2012/01/19
Temperature/Humidity
Meter Zhicheng ZC1-2 TR8-TH 2012/05/04
Note: All equipments are calibrated with traceable calibrations. Each calibration is traceable to the national
or international standards.
4.2. Test Setup
4.3. Limit The width of the power envelope is fH - fL for a given operating frequency. In equipment that allows adjustment or selection of different operating frequencies, the power envelope takes up different positions in the allowed band. The frequency range is determined by lowest value of fL
and the highest value of fH resulting from the adjustment of the equipmentto the lowest and highest operating frequencies.
Spectrum
12dBm
Temperature Chamber
Power Supply
Report No: 112S010R-RF-CE-P14V02
Page: 18 of 30
4.4. Test Procedure Refer to ETSI EN 300 440-1 V1.6.1 (2010-08) Clause 7.2
4.5. Test Result It is not suitable to perform this test item.
Report No: 112S010R-RF-CE-P14V02
Page: 19 of 30
5. Transmitter Spurious Emissions
5.1. Test Equipment Transmitter Spurious Emissions / AC-6
Instrument Manufacturer Type No. Serial No. Cal. Due Date
Spectrum Analyzer Agilent E4446A MY45300103 2012/04/30
PSG Analog S.G. Agilent E8257D MY44321116 2012/04/23
Preamplifier QuieTek AP-025C CHM-0503006 2012/05/05
Preamplifier QuieTek AP-180C CHM-0602013 2012/05/05
Bilog Type Antenna Schaffner CBL6112D 22254 2011/10/18
Half Wave Tuned
Dipole Antenna COM-POWER AD-100 40137 2011/11/24
Broad-Band Horn
Antenna Schwarzbeck BBHA9120D 499 2012/06/11
Broad-Band Horn
Antenna Schwarzbeck BBHA9120D 737 2011/11/24
High-Pass Filter Wainwright WHKX2.8/18G-12SS SN1 2012/03/03
Band Reject Filter Wainwright WRCG2400/2485-2375
/2510-60/11SS SN9 2012/03/03
Temperature/Humidity
Meter zhicheng ZC1-2 AC6-TH 2012/01/14
Note: All equipments are calibrated with traceable calibrations. Each calibration is traceable to the national
or international standards.
Report No: 112S010R-RF-CE-P14V02
Page: 20 of 30
5.2. Test Setup For Radiated Measurement
Report No: 112S010R-RF-CE-P14V02
Page: 21 of 30
5.3. Limit
Radiated Spurious Emissions for Transmitter State 47 MHz to 74 MHz
87.5 MHz to 118 MHz174 MHz to 230 MHz470 MHz to 862 MHz
Other frequencies ≦1000 MHz
Frequencies >1000 MHz
Operating 4 nW 250 nW 1 uW
Standby 2 nW 2 nW 20 nW
5.4. Test Procedure
Refer to ETSI EN 300 440-1 V1.6.1 (2010-08) Clause 7.3
5.5. Test Result
It is not suitable to perform this test item.
Report No: 112S010R-RF-CE-P14V02
Page: 22 of 30
6. Receiver Spurious Emissions
6.1. Test Equipment Receiver Spurious Emissions / AC-6
Instrument Manufacturer Type No. Serial No. Cal. Due Date
Spectrum Analyzer Agilent E4446A MY45300103 2012/04/30
PSG Analog S.G. Agilent E8257D MY44321116 2012/04/23
Preamplifier QuieTek AP-025C CHM-0503006 2012/05/05
Preamplifier QuieTek AP-180C CHM-0602013 2012/05/05
Bilog Type Antenna Schaffner CBL6112D 22254 2011/10/18
Half Wave Tuned
Dipole Antenna COM-POWER AD-100 40137 2011/11/24
Broad-Band Horn
Antenna Schwarzbeck BBHA9120D 499 2012/06/11
Broad-Band Horn
Antenna Schwarzbeck BBHA9120D 737 2011/11/24
High-Pass Filter Wainwright WHKX2.8/18G-12SS SN1 2012/03/03
Band Reject Filter Wainwright WRCG2400/2485-2375
/2510-60/11SS SN9 2012/03/03
Temperature/Humidity
Meter zhicheng ZC1-2 AC6-TH 2012/01/14
Note: All equipments are calibrated with traceable calibrations. Each calibration is traceable to the national
or international standards.
Report No: 112S010R-RF-CE-P14V02
Page: 23 of 30
6.2. Test Setup For Radiated Measurement
Report No: 112S010R-RF-CE-P14V02
Page: 24 of 30
6.3. Limit The power of any spurious emission shall not exceed 2 nW in the range 25 MHz to 1 GHz and shall not exceed 20 nW on frequencies above 1 GHz.
6.4. Test Procedure Refer to ETSI EN 300 440-1 V1.6.1 (2010-08) Clause 8.4
Report No: 112S010R-RF-CE-P14V02
Page: 25 of 30
6.5. Test Result
Product : Wireless Module
Test Item : Spurious Emission
Test Site : AC-6
Test Mode : Mode 1: GPS Receive
Frequency (MHz)
Polarization (H/V)
Measure Level(dBm)
Limit (dBm)
Margin (dB)
Detector
99.84 H -69.34 -57.0 -12.34 Peak
75.11 V -74.24 -57.0 -17.24 Peak
252.62 H -68.12 -57.0 -11.12 Peak
131.85 V -78.09 -57.0 -21.09 Peak
367.56 H -64.68 -57.0 -7.68 Peak
288.02 V -69.52 -57.0 -12.52 Peak
1238.00 H -56.66 -47.0 -9.66 Peak
1374.00 V -56.99 -47.0 -9.99 Peak
2258.00 H -54.34 -47.0 -7.34 Peak
2156.00 V -55.55 -47.0 -8.55 Peak
3703.00 H -52.56 -47.0 -5.56 Peak
2972.00 V -54.20 -47.0 -7.20 Peak
Report No: 112S010R-RF-CE-P14V02
Page: 26 of 30
6.6. Test Photograph Description: Receiver Spurious Emissions Test Setup for Below 1GHz
Description: Receiver Spurious Emissions Test Setup for Above 1GHz
Report No: 112S010R-RF-CE-P14V02
Page: 27 of 30
7. Duty Cycle
7.1. Test Equipment Duty Cycle / TR-8
Instrument Manufacturer Type No. Serial No. Cal. Due Date
Spectrum Analyzer Agilent E4446A MY45300103 2012/04/30
Temperature/Humidity
Meter Zhicheng ZC1-2 TR8-TH 2012/05/04
Note: All equipments are calibrated with traceable calibrations. Each calibration is traceable to the national
or international standards.
7.2. Test Setup
Report No: 112S010R-RF-CE-P14V02
Page: 28 of 30
7.3. Limit
Duty Cycle Limits Frequency Band Duty Cycle Application Notes
2 400 MHz to 2 483,5 MHz No Restriction Generic use 2 400 MHz to 2 483,5 MHz No Restriction Detection, movement and alert
applications
(a) 2 446 MHz to 2 454 MHz No Restriction RFID See annex C
(b) 2 446 MHz to 2 454 MHz ≤ 15 % RFID See annex C
5 725 MHz to 5 875 MHz No Restriction Generic use 9 200 MHz to 9 500 MHz No Restriction Detection, movement and alert
applications
9 500 MHz to 9 975 MHz No Restriction Detection, movement and alert
applications
10,5 GHz to 10,6 GHz No Restriction Detection, movement and alert
applications
13,4 GHz to 14,0 GHz No Restriction Detection, movement and alert
applications
17,1 GHz to 17,3 GHz DAA or equivalent
techniques
GBSAR detecting and movement and
alert applications
See annex E
24,00 GHz to 24,25 GHz No Restriction Generic use and for detection,
movement and alert applications
7.4. Test Procedure
Refer to ETSI EN 300 440-1 V1.6.1 (2010-08) Clause 7.4
7.5. Test Result
It is not suitable to perform this test item.
Report No: 112S010R-RF-CE-P14V02
Page: 29 of 30
8. Attachment EUT Photograph
(1) EUT Photo
(2) EUT Photo
Report No: 112S010R-RF-CE-P14V02
Page: 30 of 30
(3) EUT Photo
(4) EUT Photo