10
Brief description MPA-S/MPA-F with multipin connector type: MPA...-MPM-VI – English 8080182 2017-12d [8080184] Valve terminal MPA-S/MPA-F

Valve terminal MPA-S/MPA-F - festo.com · PDF file4 Festo MPA...-MPM-VI 2017-12d English 2 Multipin connection 2.1 Multipin socket Caution The components of the valve terminal contain

  • Upload
    vuhuong

  • View
    216

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Valve terminal MPA-S/MPA-F - festo.com · PDF file4 Festo MPA...-MPM-VI 2017-12d English 2 Multipin connection 2.1 Multipin socket Caution The components of the valve terminal contain

Brief description

MPA-S/MPA-Fwith multipinconnector type:MPA...-MPM-VI

– English

8080182

2017-12d

[8080184]

Valve terminal MPA-S/MPA-F

Page 2: Valve terminal MPA-S/MPA-F - festo.com · PDF file4 Festo MPA...-MPM-VI 2017-12d English 2 Multipin connection 2.1 Multipin socket Caution The components of the valve terminal contain

Festo MPA...-MPM-VI 2017-12d 2

Translation of the original instructions

Documentation on the product

For all available product documentation

� www.festo.com/pk

Copyright:

Festo AG & Co.Ruiter Straße 8273734 Esslingen Germany

Internet: �http://www.festo.comE-Mail: �[email protected]

Reproduction, distribution or sale of this document or communication ofits contents to others without express authorization is prohibited. Offenders will be liable for damages. All rights reserved in the event thata patent, utility model or design patent is registered.

English 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 3: Valve terminal MPA-S/MPA-F - festo.com · PDF file4 Festo MPA...-MPM-VI 2017-12d English 2 Multipin connection 2.1 Multipin socket Caution The components of the valve terminal contain

Festo MPA...-MPM-VI 2017-12d English 3

1 User instructionsEnglish

The MPA-S/MPA-F valve terminal has been designed ex­clusively for controlling pneumatic actuators. The maxi­mum values specified in the section “Technical specifica­tions” must be observed here. Detailed information can be

found in the Pneumatics Manual P.BE-MPA-... or P.BE-MPAF-...

Warning� Switch off the power supply before connecting or

disconnecting plugs (otherwise this could lead tofunctional damage).

� Use only power units which guarantee reliableelectrical isolation of the operating voltage as perIEC/DIN EN 60204-1 Observe also the generalrequirements for PELV power circuits as perIEC/DIN�EN�60204-1.

Please noteCommission only a valve terminal which has been fittedand wired completely.

Page 4: Valve terminal MPA-S/MPA-F - festo.com · PDF file4 Festo MPA...-MPM-VI 2017-12d English 2 Multipin connection 2.1 Multipin socket Caution The components of the valve terminal contain

Festo MPA...-MPM-VI 2017-12d English4

2 Multipin connection

2.1 Multipin socket

CautionThe components of the valve terminal contain electros­tatically sensitive elements. The components will bedamaged if you touch the contact surfaces of the plugconnectors and if you do not observe the regulationsfor handling electrostatically sensitive components.

Long signal cables reduce the immunity to interference.Do not exceed the maximum permitted signal cablelength of 10 m.

Recommendation:Use the following 25-pin multipin socket with cable from

the Festo range of acessories for connecting the MPA valveterminal with multipin connection:

Multipin socket with cable

VMPA-KMS1-8-...VMPA-KMS2-8-...

VMPA-KMS1-24-...VMPA-KMS2-24-...

Maximum 8 valve solenoid coilscan be actuated.

Maximum 24 valve solenoid coilscan be actuated.

Page 5: Valve terminal MPA-S/MPA-F - festo.com · PDF file4 Festo MPA...-MPM-VI 2017-12d English 2 Multipin connection 2.1 Multipin socket Caution The components of the valve terminal contain

Festo MPA...-MPM-VI 2017-12d English 5

1425

13 1Pin 1 corresponds to address 0 Pin 24 corresponds to address 23

2.2 Pin assignment of the sub-D multipin plug

Notes on the following table:– Core colour applies to cable type: VMPA-KMS...– Colour code of the core colours as per DIN/IEC 757– Addr. = address

Plug Pin Addr. Core colour Pin Addr. Core colour

114

2513 1

2345678910111213

0123456789101112

WHGNYEGYPKBURDVTGY PKRD BUWH GNBN GNWH YE

141516171819202122232425

13141516171819202122230 V 1)

YE BNWH GYGY BNWH PKPK BNWH BUBN BUWH RDBN RDWH BKBNBK

1) 0 V for positive-switching control signals; 24 V for negative-switching control signals; mixed operation is not permitted.

Page 6: Valve terminal MPA-S/MPA-F - festo.com · PDF file4 Festo MPA...-MPM-VI 2017-12d English 2 Multipin connection 2.1 Multipin socket Caution The components of the valve terminal contain

Festo MPA...-MPM-VI 2017-12d English6

3 Controlling the valve terminal

Use a uniform method of control. Preferably, all controlsignals should be positive-switching (1-switching), other­wise all control signals negative-switching (0-switching).Mixed mode control is not permitted.

3.1 Address assignment of the valves

– Assign the addresses in ascending order without gaps(see example).

– Addess assignment does not depend on whetherblanking plates or valve plates are fitted.

– Depending on the electronic module, a valve locationoccupies the following number of addresses:

Number ofaddresses

Electronic module

MPA 1 MPA 2

one address VMPA1-MPM-EMM-4 VMPA2-MPM-EMM-2

two addresses VMPA1-MPM-EMM-8 VMPA2-MPM-EMM-4

– If an electronic module occupies 2 addresses, thefollowing applies:– pilot solenoid 14 occupies the lower-value address;– pilot solenoid 12 occupies the higher-value address.

Page 7: Valve terminal MPA-S/MPA-F - festo.com · PDF file4 Festo MPA...-MPM-VI 2017-12d English 2 Multipin connection 2.1 Multipin socket Caution The components of the valve terminal contain

Festo MPA...-MPM-VI 2017-12d English 7

Example of address assignment

CautionNote that addresses may be shifted if the valve terminalis extended at a later stage.

In the example an MPA valve terminal with the folllowingcomponents is addressed:

Components MPA 1 MPA 2

Sub-bases 2 (8 valve locations) 2 (4 valve locations)

Electronic module 1 VMPA1-MPM-EMM-81 VMPA1-MPM-EMM-4

1 VMPA2-MPM-EMM-41 VMPA2-MPM-EMM-2

For controlling the valves, each valve solenoid coil (referredto in the following as coil) is assigned to a certain pin of themultipin plug.

Page 8: Valve terminal MPA-S/MPA-F - festo.com · PDF file4 Festo MPA...-MPM-VI 2017-12d English 2 Multipin connection 2.1 Multipin socket Caution The components of the valve terminal contain

Festo MPA...-MPM-VI 2017-12d English8

Pin Address Valve locationnumber

Coil Electronic module

12

01

0 1412

VMPA1-MPM-EMM-8

34

23

1 1412

56

45

2 1412

78

67

3 1412

9 8 4 14 VMPA2-MPM-EMM-2

10 9 5 14

11 10 6 14 VMPA1-MPM-EMM-4

12 11 7 14

13 12 8 14

14 13 9 14

1516

1415

10 1412

VMPA2-MPM-EMM-4

1718

1617

11 1412

... ... ... ... ...

25 0 V 1)

1) 0 V for positive-switching control signals; 24 V for control signals; mixed operation is not permitted.

Page 9: Valve terminal MPA-S/MPA-F - festo.com · PDF file4 Festo MPA...-MPM-VI 2017-12d English 2 Multipin connection 2.1 Multipin socket Caution The components of the valve terminal contain

Festo MPA...-MPM-VI 2017-12d English 9

Example of address assignment (seen from above):

2

15 14 17

1 2 3 4

7

4

9 8

35

6

1 5

2

1

0

1 3

4

5

6

7 8 9

10 11 12 13

16

1

aJ

1 Addresses of coils 14(manual override 14)

2 Addresses of coils 12(manual override 12)

3 LED for coil 12

4 LED for coil 14

5 Unused valve location

6 Pin assignment withelectronic moduleVMPA2-MPM-EMM-4occupies two addressesper valve location

7 Supply block for additionalpressure supply

8 Pin assignment with electronicmodule VMPA1-MPM-EMM-4occupies one address per valvelocation

9 Pin assignment with electronicmodule VMPA2-MPM-EMM-2occupies one address per valvelocation

aJ Pin assignment with electronicmodule VMPA1-MPM-EMM-8occupies two addresses pervalve location

Page 10: Valve terminal MPA-S/MPA-F - festo.com · PDF file4 Festo MPA...-MPM-VI 2017-12d English 2 Multipin connection 2.1 Multipin socket Caution The components of the valve terminal contain

Festo MPA...-MPM-VI 2017-12d English10

4 Technical specifications and accessories

Type: MPA...-MPM-VI 1) MPA1 MPA2

Number of valve locations 4, 8, 12...24 2) 2, 4, 6...24 2)

Current consumption per solenidcoil at 24 V– Rated pick-up current/duration– Rated current with current

reduction

80 mA/25 ms25 mA

100 mA/50 ms20 mA

Control voltage:– Rated value (protected against

incorrect polarity)– Tolerance

24 V DC

± 25 % (18...30 V DC)

Protection class as per DIN 40050 IP65 (fitted completely)

Protection against electric shock By the use of PELV currentcircuits (protection against directand indirect contact as perIEC/DIN EN�60204-1)

Ambient temperatureStorage temperature

- 5 ... + 50 °C- 20 ... + 40 °C

Electromagnetic� compatibility– Interference emitted 3)

– Immunity to interference 4)See declaration of conformity� www.festo.com

1) Dimensions and materials: See Pneumatics Manual2) Maximum 24 valve solenoid coils can be controlled3) The valve terminal is intended for industrial usage4) The maximum permitted signal cable length is 10 m