6
11kV SINGLE CORE AND 3 CORE INDOOR TERMINATIONS PLASTIC INSULATED CABLE 10 16 25 35 50 70 95 120 150 185 240 300 400 500 800 1000 EPKT-17A1XI EPKT-17E1XI EPKT-17F1XI OVERLAP IXSU-F 3151 OVERLAP OVERLAP OVERLAP EPKT-17A3XIH1 EPKT-17E3XIH1 EPKT-17F3XIH1 IXSU-F 3301 IXSU-F 3311 OVERLAP EPKT-17A3XIH2 EPKT-17E3XIH2 EPKT-17F3XIH2 EPKT-17A3XIH3 EPKT-17E3XIH3 EPKT-17F3XIH3 EPKT-17A3XIH4 EPKT-17E3XIH4 EPKT-17F3XIH4 IXSU-F3304 IXSU-F 3314 OVERLAP 10 16 25 35 50 70 95 120 150 185 240 300 400 500 800 1000 CROSS SECTIONAL AREA IN SQMM OVERLAP EPKT-17D1XI IXSU-F 3141 EPKT-17D3XIH2 TFTI-3111 EPKT-17D3XIH1 IXSU-F 3341 TFTI-3131 850 TAIL LENGTH EPKT-17C1XI EPKT-17C3XIH1 EPKT-17C3XIH2 EPKT-17C3XIH3 450 TAIL LENGTH EPKT-17B3XIH1 IXSU-F 3321 IXSU-F 3331 TFTI-3121 SINGLE CORE EPKT-17B1XI IXSU-F 3111 IXSU-F 3121 TFTI-3112 TFTI-3122 IXSU-F 3131 IXSU-F 3334 IXSU-F 3344 EPKT-17C3XIH4 TFTI-3132 EPKT-17B3XIH3 EPKT-17D3XIH3 KITS ADJACENT TO THIS RANGE, BOTH OVERLAP THIS RANGE. 3 CORE 650 TAIL LENGTH EPKT-17B3XIH2 1200 TAIL LENGTH EPKT-17B3XIH4 EPKT-17D3XIH4 IXSU-F 3324

raychem Kits adjacent to this range, both overlap this range

Embed Size (px)

Citation preview

Page 1: raychem Kits adjacent to this range, both overlap this range

11kV SINGLE CORE AND 3 CORE INDOOR TERMINATIONSPLASTIC INSULATED CABLE

10 16 25 35 50 70 95 120 150 185 240 300 400 500 800 1000

EPKT-17A1XI EPKT-17E1XI EPKT-17F1XI

OVERLAP IXSU-F 3151

OVERLAP

OVERLAP OVERLAP

EPKT-17A3XIH1 EPKT-17E3XIH1 EPKT-17F3XIH1

IXSU-F 3301 IXSU-F 3311 OVERLAP

EPKT-17A3XIH2 EPKT-17E3XIH2 EPKT-17F3XIH2

EPKT-17A3XIH3 EPKT-17E3XIH3 EPKT-17F3XIH3

EPKT-17A3XIH4 EPKT-17E3XIH4 EPKT-17F3XIH4

IXSU-F3304 IXSU-F 3314 OVERLAP

10 16 25 35 50 70 95 120 150 185 240 300 400 500 800 1000

CROSS SECTIONAL AREA IN SQMM

OVERLAP

EPKT-17D1XI

IXSU-F 3141

EPKT-17D3XIH2

TFTI-3111

EPKT-17D3XIH1

IXSU-F 3341

TFTI-3131

850

TAIL

LE

NG

TH

EPKT-17C1XI

EPKT-17C3XIH1

EPKT-17C3XIH2

EPKT-17C3XIH3

450

TAIL

LE

NG

TH

EPKT-17B3XIH1

IXSU-F 3321 IXSU-F 3331

TFTI-3121

SIN

GLE

CO

RE

EPKT-17B1XI

IXSU-F 3111 IXSU-F 3121

TFTI-3112 TFTI-3122

IXSU-F 3131

IXSU-F 3334 IXSU-F 3344

EPKT-17C3XIH4

TFTI-3132

EPKT-17B3XIH3 EPKT-17D3XIH3

KITS ADJACENT TO THIS RANGE, BOTH OVERLAP THIS RANGE.

3 C

OR

E 650

TAIL

LE

NG

TH

EPKT-17B3XIH2

1200

TA

IL

LEN

GTH

EPKT-17B3XIH4 EPKT-17D3XIH4

IXSU-F 3324

Page 2: raychem Kits adjacent to this range, both overlap this range

11kV SINGLE CORE AND 3 CORE OUTDOOR TERMINATIONS PLASTIC INSULATED CABLE

10 16 25 35 50 70 95 120 150 185 240 300 400 500 800 1000

EPKT-17A1XO EPKT-17E1XO EPKT-17F1XO

OVERLAP OXSU-F 3151

OVERLAP

OVERLAP OVERLAP

EPKT-17A3XOH1 EPKT-17E3XOH1 EPKT-17F3XOH1

OXSU-F 3301 OXSU-F 3311 OVERLAP

EPKT-17A3XOH2 EPKT-17E3XOH2 EPKT-17F3XOH2

EPKT-17A3XOH3 EPKT-17E3XOH3 EPKT-17F3XOH3

EPKT-17A3XOH4 EPKT-17E3XOH4 EPKT-17F3XOH4

OXSU-F3304 OXSU-F 3314 OVERLAP

10 16 25 35 50 70 95 120 150 185 240 300 400 500 800 1000

CROSS SECTIONAL AREA IN SQMM

OVERLAP

EPKT-17C3XOH4

OXSU-F 3141OXSU-F 3131

EPKT-17D3XOH3

EPKT-17D3XOH2

OXSU-F 3341OXSU-F 3331

TFTO-3122

EPKT-17C3XOH1

TFTO-3121

OXSU-F 3344

EPKT-17D3XOH4

OXSU-F 3111

OXSU-F 3324

EPKT-17B3XOH3

EPKT-17B3XOH4

TFTO-3112 TFTO-3132

EPKT-17C3XOH2

OXSU-F 3334

EPKT-17C3XOH3

EPKT-17D1XO

EPKT-17B3XOH1 EPKT-17D3XOH1

OXSU-F 3121

EPKT-17C1XO

TFTO-3111 TFTO-3131

KITS ADJACENT TO THIS RANGE, BOTH OVERLAP THIS RANGE.

SIN

GLE

C

OR

E3

CO

RE

450

TAIL

LE

NG

TH65

0 TA

IL

LEN

GTH

850

TAIL

LE

NG

TH12

00 T

AIL

LE

NG

TH

OXSU-F 3321

EPKT-17B3XOH2

EPKT-17B1XO

Page 3: raychem Kits adjacent to this range, both overlap this range

22kV SINGLE CORE AND 3 CORE INDOOR TERMINATIONSPLASTIC INSULATED CABLE

10 16 25 35 50 70 95 120 185 240 300 400 500 630 800 1000

EPKT-24D1XI

OVERLAP

OVERLAP TFTI-5142

OVERLAP

EPKT-24D3XIH2

EPKT-24D3XIH3

EPKT-24D3XIH4

10 16 25 35 50 70 95 120 185 240 300 400 500 630 800 1000

CROSS SECTIONAL AREA IN SQMM

OVERLAP

TFTI-5122 TFTI-5132

TFTI-5121 TFTI-5131 TFTI-5141

EPKT-24F3XIH3

EPKT-24F3XIH4

EPKT-24F3XIH2

EPKT-24E3XIH4EPKT-24B3XIH4

EPKT-24E3XIH2

EPKT-24C3XIH4

EPKT-24C3XIH3 EPKT-24E3XIH3

KITS ADJACENT TO THIS RANGE, BOTH OVERLAP THIS RANGE.

SIN

GLE

CO

RE

3 C

OR

E

450

TAIL

LEN

GTH

850

TAIL

LE

NG

TH12

00 T

AIL

LE

NG

TH

EPKT-24C3XIH2

IXSU-F 5334 IXSU-F 5344

650

TAIL

LE

NG

TH

EPKT-24B3XIH2

IXSU-F 5321

IXSU-F 5314 IXSU-F 5324

IXSU-F 5131

EPKT-24E1XI

IXSU-F 5341

IXSU-F 5151

IXSU-F 5331

EPKT-24C1XIEPKT-24B1XI

IXSU-F 5311

EPKT-24B3XIH3

IXSU-F 5121

EPKT TERMINATION NOT ALLOWED, AS TAIL LENGTH MIN ON 24kV INDOOR TERMINATIONS IS 650MM

EPKT-24F1XI

IXSU-F 5141

Page 4: raychem Kits adjacent to this range, both overlap this range

22kV SINGLE CORE AND 3 CORE OUTDOOR TERMINATIONSPLASTIC INSULATED CABLE

10 16 25 35 50 70 95 120 185 240 300 400 500 630 800 1000

EPKT-24D3X0 EPKT-24F1XO

OVERLAP

OVERLAP TFTO-5142

OVERLAP

EPKT-24D3XOH3 EPKT-24F3XOH3

EPKT-24D3XOH4 EPKT-24F3XOH4

10 16 25 35 50 70 95 120 185 240 300 400 500 630 800 1000

CROSS SECTIONAL AREA IN SQMM

OVERLAP

OXSU-F 5341

EPKT TERMINATION NOT ALLOWED, AS TAIL LENGTH MIN ON 24kV OUTDOOR TERMINATIONS IS 850MM

EPKT-24E3XOH4

TFTO-5122 TFTO-5132

TFTO-5121 TFTO-5131 TFTO-5141

EPKT TERMINATION NOT ALLOWED, AS TAIL LENGTH MIN ON 24kV OUTDOOR TERMINATIONS IS 850MM

SIN

GLE

CO

RE

3 C

OR

E

850

TAIL

LE

NG

TH45

0 TA

IL L

ENG

TH65

0 TA

IL

LEN

GTH

1200

TA

IL

LEN

GTH

EPKT-24E1XO

EPKT-24C3XOH3 EPKT-24E3XOH3

EPKT-24B1XO

OXSU-F 5121 OXSU-F 5131

EPKT-24C1XO

OXSU-F 5141 OXSU-F 5151

OXSU-F 5331

KITS ADJACENT TO THIS RANGE, BOTH OVERLAP THIS RANGE.

OXSU-F 5311

OXSU-F 5314

EPKT-24B3XOH3

EPKT-24B3XOH4

OXSU-F 5324

OXSU-F 5321

OXSU-F 5334 OXSU-F 5344

EPKT-24C3XOH4

Page 5: raychem Kits adjacent to this range, both overlap this range

33kV SINGLE CORE AND 3 CORE INDOOR TERMINATIONSPLASTIC INSULATED CABLES

10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000

OVERLAP OVERLAP TFTI-6151

IXSU-F 6352

IXSU-F 6354

10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000

CROSS SECTIONAL AREA IN SQMM

OVERLAP

EPKT-36F3XIH4

IXSU-F 6151

EPKT-36E3XIH3 EPKT-36F3XIH3

IXSU-F 6141

IXSU-F 6342

EPKT-36E3XIH4

EPKT-36E1XI

EPKT-36E3XIH2

IXSU-F 6131

EPKT-36F1XI

EPKT-36F3XIH2

KITS ADJACENT TO THIS RANGE, BOTH OVERLAP THIS RANGE.

TFTI-6131 TFTI-6141

1200

TA

IL

LEN

GTH EPKT-36C3XIH4

IXSU-F 6334

EPKT-36D3XIH4

IXSU-F 6344

850

TAIL

LE

NG

TH

EPKT-36C3XIH3

IXSU-F 6332

450

TAIL

LE

NG

TH

EPKT TERMINATION NOT ALLOWED, AS TAIL LENGTH MIN ON 36kV INDOOR TERMINATIONS IS 650MM

3 C

OR

E

EPKT-36D1XI

EPKT-36D3XIH2

EPKT-36D3XIH3

TFTI-6132 TFTI-6142

SIN

GLE

C

OR

E

EPKT-36C1XI

650

TAIL

LE

NG

TH EPKT-36C3XIH2

Page 6: raychem Kits adjacent to this range, both overlap this range

33kV SINGLE CORE AND 3 CORE OUTDOOR TERMINATIONSPLASTIC INSULATED CABLE

10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000

OVERLAP OVERLAP TFTO-6151

10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000

CROSS SECTIONAL AREA IN SQMM

OVERLAP

EPKT-36F3XOH4

EPKT-36F1XO

EPKT-36F3XOH3

OXSU-F 6151

EPKT TERMINATION NOT ALLOWED, AS TAIL LENGTH MIN ON 36kV INDOOR TERMINATIONS IS 850MM

EPKT TERMINATION NOT ALLOWED, AS TAIL LENGTH MIN ON 36kV INDOOR TERMINATIONS IS 850MM

OXSU-F 6354OXSU-F 6344

EPKT-36E1XO

EPKT-36E3XOH3

EPKT-36E3XOH4

OXSU-F 6352

KITS ADJACENT TO THIS RANGE, BOTH OVERLAP THIS RANGE.

EPKT-36C3XOH3

EPKT-36C3XOH4

OXSU-F 6332

OXSU-F 6334

EPKT-36D3XOH3

EPKT-36D3XOH4

1200

TA

IL

LEN

GTH

OXSU-F 6131

EPKT-36C1XO EPKT-36D1XO

TFTO-6141

TFTO-6142

650

TAIL

LE

NG

TH

SIN

GLE

C

OR

E3

CO

RE

450

TAIL

LE

NG

TH

TFTO-6132

850

TAIL

LE

NG

TH

TFTO-6131

OXSU-F 6342

OXSU-F 6141

MOHD. BIN AHMED AKBAR TRADING EST.

(Electrical, Automation & Instrumentation)

Al Sahaba Street | P.O Box 30073 | Jubail 31951 | Kingdom of Saudi Arabia

Tel: 00966 (0) 13 3635225, 13 3618081 | Fax: 00966 (0) 13 363 3883 |

[email protected] | www.akbartrading.com