4
Protection for TV, satellite and radio systems Application Note AN006 for Cable TV, Master Antenna TV & IRS, Satellite TV systems and Terrestrial TV & Radio protectors ESP CATV/F, ESP MATV/F, ESP SMATV/F, ESP TV/EURO, ESP TV/F

Protection for TV, satalite and Radio systems

  • Upload
    furse

  • View
    34

  • Download
    1

Embed Size (px)

DESCRIPTION

ESP TV Series protectors provide combined Category C, B tested protection (to BS EN/ IEC 61643-21) suitable for use on analogue and digital cable, terrestrial and satalite TV systems.

Citation preview

Page 1: Protection for TV, satalite and Radio systems

Protection for TV, satellite and radio systems

Application Note AN006 for Cable TV, Master Antenna TV & IRS, Satellite TV systems and Terrestrial TV & Radio protectors

ESP CATV/F, ESP MATV/F, ESP SMATV/F, ESP TV/EURO, ESP TV/F

Page 2: Protection for TV, satalite and Radio systems

Protection for TV, satellite and radio sytems

AN006 | page 2

ESP TV Series protectors providecombined Category C, B tested protection (to BS EN/IEC 61643-21),suitable for use on analogue and digitalCable, Terrestrial and Satellite TV systems.

Protectors include as standard:

Very low let-through voltage (enhanced protection to BS EN 62305) between all lines

Full Mode protection, permitting continuous operation of equipment, even during surge activity

Low attenuation and high return loss over a wide range of frequencies, to ensure system performance is not impaired

Substantial earth termination

Robust die cast metal housing with holes for flat mounting

InstallationInstall on lines running within buildingsat boundaries up to LPZ 1 through to LPZ 3 to protect sensitive electronicequipment from transient damage.

Connect in series with the coaxial cable eithernear where it enters or leaves each building orclose to the equipment being protected.

The line end must be connected to the coaxial cable entering or exiting, with theclean end connected to the equipment(see installation diagram below).

Cables connected to the protector’s clean endshould never be routed next to the dirty lineend or the earth bond, to avoid transientsbeing re-introduced after the protector.

POWERDISTRIBUTION

UNIT

POWER

EQUIPMENT

Lightning Barrier

INCOMING/OUTGOING LINE

DIRTY

CLEANTo equipment

EARTH

From line

Page 3: Protection for TV, satalite and Radio systems

Application Note: AN006

page 3 | AN006

Terrestrial Analogue/Digital(Freeview™) TV and FM/DABradio protectionThe ESP TV/EURO and the ESP TV/F aresuitable for protecting standard un-amplifiedTV aerial feeds, whether the feed is foranalogue or digital reception.

The only technical differences between thetwo units are the connectors.

For standard Euro TV push-fit connectors,use the ESP TV/Euro

For F-type screw-fit connectors, use the ESP TV/F

Install in-line (in series) following guidelines in‘Installation’ opposite.

Cable (CATV) TV and cable broadband internet protectionThe ESP CATV/F is suitable for protecting bothCable TV and Broadband Internet cable feeds.

Install in-line (in series) following guidelines in‘Installation’ opposite.

Master Antenna TV protectionThe ESP MATV/F is suitable for protectingMaster Antenna TV and Integrated ReceptionSystem (IRS) feeds.

The ESP MATV/F is a wideband surgeprotector as it covers the combined signalsfrom radio, terrestrial, cable and satellite TVfeeds for distribution systems.

These are typically used in hotels and forpublic entertainment purposes.

Ideally an aerial feed and/or satellite feedshould be protected at the entry point to the building before it is connected to anMATV system.

The internal MATV lines should then beinherently protected. However if that setup isnot possible or the MATV cabling runs outsideof the building then the ESP MATV/F shouldbe installed in-line with the MATV feed asclose as possible to where the cabling entersand/or leaves the building.

Attention should also be paid toprotecting the power feeding thereceivers for each system.

Protect the receiver equipment locallywith a low-current in-line solution, orall equipment within the building byusing a parallel-connected solution atthe main distribution board.

Contact Furse for more details.

TV System Part Code ConnectionType

Bandwidth Max WorkingVoltage

TerrestrialTV/Radio ESP TV/EURO Euro TV female 5 – 860 MHz 6.4 V

TerrestrialTV/Radio ESP TV/F F-type female 5 – 860 MHz 6.4 V

Cable TV ESP CATV/F F-type female 5 – 860 MHz 140 V

MATV TV ESP MATV/F F-type female 5 – 2450 MHz 18 V

Satellite TV ESP SMATV/F F-type female 860 – 2450 MHz 18 V

Satellite TV protectionThe ESP SMATV/F is suitable for protectingsatellite TV feeds.

The surge protector should be installed in-line with the satellite feed as close aspossible to where the cabling enters the building.

Fitting an additional ESP SMATV/F as close as possible to the satellite dish can provideprotection for the satellite dish circuitry.

Page 4: Protection for TV, satalite and Radio systems

UK OFFICE

Thomas & Betts Limited

Furse

Wilford Road

Nottingham

NG2 1EB

United Kingdom

Switchboard +44 (0)115 964 3700

Fax +44 (0)115 986 0538

Sales tel +44 (0)115 964 3800

Sales fax +44 (0)115 986 0071

Email: [email protected]

www.furse.com

EUROPEAN HEADQUARTERS

Thomas & Betts

200 Chaussée de Waterloo

B-1640 Rhode-St-Genèse

Belgium

Tel +32 (0)2 359 8200

Fax +32 (0)2 359 8201

www.tnb-europe.com

MIDDLE EAST OFFICE

Thomas & Betts Ltd. Br.

Office 107 5EA East Wing

Dubai Airport Free Zone

PO Box 54567

Dubai

United Arab Emirates

Tel +971 (0)4 609 1635

Fax +971 (0)4 609 1636

Email: [email protected]

SOUTH EAST ASIA OFFICE

Thomas & Betts Asia (Singapore) Pte Ltd

10 Ang Mo Kio Street 65

#06-07 Techpoint

Singapore 569059

Tel +65 6720 8828

Fax +65 6720 8780

Email: [email protected]

The content of this Thomas & Betts publication has been carefully checked for accuracy at the time of print. However, Thomas & Bettsdoesn’t give any warranty of any kind, express or implied, in this respect and shall not be liable for any loss or damage that may resultfrom any use or as a consequence of any inaccuracies in or any omissions from the information which it may contain. E&OE.

Copyright Thomas & Betts Corp. 2010. Copyright in these pages is owned by Thomas & Betts except where otherwise indicated. No part ofthis publication may be reproduced, copied or transmitted in any form or by any means, without our prior written permission. Images,trade marks, brands, designs and technology are also protected by other intellectual property rights and may not be reproduced or appropriated in any manner without written permission of their respective owners. Thomas & Betts reserves the right to change andimprove any product specifications or other mentions in the publication at its own discretion and at any time. These conditions of use aregoverned by the laws of the Netherlands and the courts of Amsterdam shall have exclusive jurisdiction in any dispute.

AN006-0610

Full specifications of all of the products inthe Furse ESP range of transientovervoltageprotectors can befound in the TotalSolution ProductCatalogue.

To request a copy,contact Furse Salesat the address opposite.

Full product data can be downloaded in PDF form from our website atwww.furse.com. Copies of the Total Solution Product Catalogue can also be requested from our website.