Solar PV plants remote monitoring

Please consider the environment before printing this documentAsk to AdvanticSYS for printer-friendly version

© Advantic Sistemas y Servicios 2013

Inverters

RS232 / RS485

Solar irradiance

& wind speed

Temperature

probe

Up to 4

digital sensors

12 Vdc

Battery

Modbus Power

Analyzer

GPRSTransmission

- GSM/GPRS modem

- Datalogger for safe data store in case of loss of commu-nications.

- Two independent communication ports (RS485 / RS232 selectables) ready to connect inverters, counters, power anaylzers... using standard or propietary protocols.

- Two analogue inputs (0..20mA / 0..10V) for solar irradi-ance and environmental sensors*

- Standard PT100 or PT1000 temperature probe input

- Four configurable discrete inputs for discrete sensors, alarms or pulse counting*

- Battery charger included to prevent communications - Battery charger included to prevent communications being interrupted in case of blackout.

* If you need more signals, ask to Advantic for expansion modules (+8 analogue inputs +32 discrete inputs)

2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017

423 GW

102 GW

Although solar power is an energy source that we have only recently tapped into, it may easily become the most important energy source of the future.

At the end of 2012, global PV capacity was 102 GW. EPIA outlook until 2017 is more than four times this number. All of this systems need to be monitored to detect breakdown and optimize their operation.

MPC-143 is a compact datalogger specially designed to integrate all the signals involved in O&M (operation and maintenance),bringing a bringing a cost-effective and easy way to remote monitoring the complete system.

Are you missing any feature? Still don’t know if MPC-143 will meet your requirements?

OPERATION

Looks complicated? No problem, MPC-143 can do the work for you by sending periodically CSV filesdirectly to your server. This M2M functionallity dramatically reduces software integration complexity.

Because we know that time is money, our controllers are designed to improve installation time. With removeable screw terminals, all of them correctly labeled, installation will take less than 5 min.

Modbus protocol holds no secrets. MPC-143 will ask for data to inverter, counter and power analyzer at selected interval and store securely the data. Commercial or custom software, SCADA or any platform using standard Modbus protocol can recover data from controller.

Despite being a high tech device, MPC-143 consumption is less than one energy-saving light bulb.In case of emergency, a small 12Vdc 7 Ah battery is enough to keep device working more than 72 h

MPC-143 will also help you to save money. SIM cards with static IP are expensive, so we already support DynDNS service in order to avoid the need of pay for it.