65
DIRECT SENSING SAMPLING INSTALLATION INJECTIONS ZEBRA ENVIRONMENTAL DIRECT SENSING

Zebra Direct Sensing MIP-CPT-HPT-LIF

Embed Size (px)

DESCRIPTION

All

Citation preview

Page 1: Zebra Direct Sensing MIP-CPT-HPT-LIF

•DIRECT SENSING

•SAMPLING

•INSTALLATION

•INJECTIONS

ZEBRA ENVIRONMENTAL

DIRECT SENSING

Page 2: Zebra Direct Sensing MIP-CPT-HPT-LIF

The Total System

MIP DIRECT SENSING

Page 3: Zebra Direct Sensing MIP-CPT-HPT-LIF

What is the Membrane Interface Probe?

The Membrane Interface Probe (MIP) is rapid, high-resolution field screening technology that provides information about relative concentrations of VOCs in the subsurface, and the Electrical Conductivity of the soil.

The MIP uses a thin film fluorocarbon polymer membrane approx. 6.35mm in diameter which stays in direct contact with the soil during MIP logging. •The thin film membrane is impregnated into a stainless steel screen which serves as a rigid support for the fluorocarbon polymer. •The down-hole, permeable membrane serves as an interface to a detector at the surface. •Volatiles in the subsurface are getting transferred across the membrane and partition into a stream of carrier gas where they are swept to the detector. The membrane is heated in order to facilitate VOC transfer and self-cleaning.

DIRECT SENSING

Page 4: Zebra Direct Sensing MIP-CPT-HPT-LIF

THE MIP PROBE

DIRECT SENSING

EC Dipole

Membrane

Heater Block

Page 5: Zebra Direct Sensing MIP-CPT-HPT-LIF

THE MIP TRUNKLINE

DIRECT SENSING

Page 6: Zebra Direct Sensing MIP-CPT-HPT-LIF

The System Components

DIRECT SENSING

Page 7: Zebra Direct Sensing MIP-CPT-HPT-LIF

FID

PID

ECD

DIRECT SENSING

Page 8: Zebra Direct Sensing MIP-CPT-HPT-LIF

MIP Detection Limits

MIP DETECTORS

Contaminates Detection Limit Carrier Gas

PID BTEX 1 PPM Nitrogen, Helium

FID Methane, Butane NA Nitrogen, Helium

ECD Chlorinateds 250PPB Nitrogen

DIRECT SENSING

Page 9: Zebra Direct Sensing MIP-CPT-HPT-LIF

The MIP Carrier Vehicle

Rods

Generator

DIRECT SENSING

Page 10: Zebra Direct Sensing MIP-CPT-HPT-LIF

Production rates: 150’ to 300’ per day.

The production rate of the MIP is affected by :

• the number of logging locations

• the depth of logging

• subsurface conditions

• access restrictions

• probe hole abandonment requirements

• weather

DIRECT SENSING

Page 11: Zebra Direct Sensing MIP-CPT-HPT-LIF

MIP LOGGING

DIRECT SENSING

Page 12: Zebra Direct Sensing MIP-CPT-HPT-LIF

Pre Log Response

DIRECT SENSING

Page 13: Zebra Direct Sensing MIP-CPT-HPT-LIF

Example of a Microsoft Excel Spreadsheet graphically displaying FID/PID/ECD and Conductivity Logs.

DIRECT SENSING

Page 14: Zebra Direct Sensing MIP-CPT-HPT-LIF

Post Log Response

DIRECT SENSING

Page 15: Zebra Direct Sensing MIP-CPT-HPT-LIF

The Gator

DIRECT SENSING

Page 16: Zebra Direct Sensing MIP-CPT-HPT-LIF

Gator In Action

DIRECT SENSING

Page 17: Zebra Direct Sensing MIP-CPT-HPT-LIF

New and Improved

DIRECT SENSING

Page 18: Zebra Direct Sensing MIP-CPT-HPT-LIF

DIRECT SENSING

Heated Trunkline

Page 19: Zebra Direct Sensing MIP-CPT-HPT-LIF

CPT/MIP

DIRECT SENSING

Page 20: Zebra Direct Sensing MIP-CPT-HPT-LIF

CPT/MIPCPT is (Cone Penetration Testing) commonly used to determine the subsurface stratigraphy in-situ and to estimate geotechnical parameters of the materials present in the subsurface.

•Collect real time physical descriptions •Collect physical properties of the soil matrix•Tag a confining layer•Cost savings over more traditional boring and sampling methods

DIRECT SENSING

Advantages:

Disadvantages:

•Must be pushed

Page 21: Zebra Direct Sensing MIP-CPT-HPT-LIF

CPT/MIP

ZEBRA ENVIRONMENTAL CPT/MIP

Page 22: Zebra Direct Sensing MIP-CPT-HPT-LIF

CPT/MIP

ZEBRA ENVIRONMENTAL CPT/MIP

Page 23: Zebra Direct Sensing MIP-CPT-HPT-LIF

CPT/MIP Unit

ZEBRA ENVIRONMENTAL CPT/MIP

Page 24: Zebra Direct Sensing MIP-CPT-HPT-LIF

CPT/MIP Anchoring

ZEBRA ENVIRONMENTAL CPT/MIP

Page 25: Zebra Direct Sensing MIP-CPT-HPT-LIF

CPT Response Graph

Sleeve Friction

Tip PressureLithology

Description

Friction Ratio

Pore Pressure

ZEBRA ENVIRONMENTAL CPT/MIP

Page 26: Zebra Direct Sensing MIP-CPT-HPT-LIF

CPT/MIP

ZEBRA ENVIRONMENTAL CPT/MIP

Page 27: Zebra Direct Sensing MIP-CPT-HPT-LIF

DATA

DATA INTEGRATION

Page 28: Zebra Direct Sensing MIP-CPT-HPT-LIF

SHAREPOINT WEBSITE FOR DATA SHARING

DATA INTEGRATION

Page 29: Zebra Direct Sensing MIP-CPT-HPT-LIF

DATA INTEGRATION

Remediation System Tracking (Multiple Mobilizations

2006

2008

2009

Page 30: Zebra Direct Sensing MIP-CPT-HPT-LIF

Cross-section from a 2D ECD Fence Slice.

Installed MW overlay ECD Background Slice

Sampling Event DataLithologyOverlay

ECD Graph Overlay

DATA INTEGRATION

Page 31: Zebra Direct Sensing MIP-CPT-HPT-LIF

Using 3D modeling software, we can generate true 3D Solid Models. This Plan View model was created using ECD data from a recent MIP project . Any orientation can be displayed and cross-sections or fence diagrams can be created.

DATA INTEGRATION

Page 32: Zebra Direct Sensing MIP-CPT-HPT-LIF

3D ECD Fence Model

DATA INTEGRATION

Page 33: Zebra Direct Sensing MIP-CPT-HPT-LIF

3D ECD Solid Plume Model

DATA INTEGRATION

Page 34: Zebra Direct Sensing MIP-CPT-HPT-LIF

3D Solid Model with Surface Objects

DATA INTEGRATION

Page 35: Zebra Direct Sensing MIP-CPT-HPT-LIF

1-800-PROBE-IT

www.TeamZEBRA.com

ZEBRA Environmental Corporation 2010

For more information about the Membrane Interface Probe:

MIP DIRECT SENSING

Page 36: Zebra Direct Sensing MIP-CPT-HPT-LIF

New HPT

Hydraulic Profiling Tool (HPT)

Page 37: Zebra Direct Sensing MIP-CPT-HPT-LIF

New direct push technologies

•HPT Logging•Rhode Island

Hydraulic Profiling Tool (HPT)

Page 38: Zebra Direct Sensing MIP-CPT-HPT-LIF

Hydraulic Profiling Tool (HPT)

Page 39: Zebra Direct Sensing MIP-CPT-HPT-LIF

Hydraulic Profiling Tool (HPT)Hydraulic Profiling Tool (HPT)

Page 40: Zebra Direct Sensing MIP-CPT-HPT-LIF

• Advance probe at constant rate

• Inject water at low flow rate

• Measure formation pressure response

2 cm/sec

Hydraulic Profiling Tool (HPT)

Page 41: Zebra Direct Sensing MIP-CPT-HPT-LIF

KDHE2 - 5th and Pine - Salina, KS - 4/7/06

0

10

20

30

40

50

60

70

80

90

100

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70

Depth (ft)

Ele

ctr

ica

l Co

nd

uc

tiv

ity

(m

S/m

)

0

20

40

60

80

100

120

HP

T P

ress

ure

(p

si)

Electrical Conductivity (mS/m) HPT Pressure (psi)

Hydraulic Profiling Tool (HPT)

Page 42: Zebra Direct Sensing MIP-CPT-HPT-LIF

Depth

SWL = Depth – Static Pressure

52ft – 21psi = 31ft

21psi

52ftStatic Pressure

Flow = 0ROP = 0

Dissipation Test

Page 43: Zebra Direct Sensing MIP-CPT-HPT-LIF

KDHE3 - 5th and Pine - Salina, KS - 4/11/06

0

10

20

30

40

50

60

70

80

90

100

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70Depth (ft)

Ele

ctri

cal C

ondu

ctiv

ity

(mS

/m)

0

20

40

60

80

100

120

HP

T P

ress

ure

(psi

)

Electrical Conductivity (mS/m) HPT Pressure (psi)

SWL = Depth – Static Pressure

Hydraulic Profiling Tool (HPT)

Page 44: Zebra Direct Sensing MIP-CPT-HPT-LIF

31 ftDPT Injection

HPT SOLUTIONS

Injection WellsMW Wells

Page 45: Zebra Direct Sensing MIP-CPT-HPT-LIF

HPT VA SITE Case Study - HPT VA Site

Hydraulic Profiling Tool (HPT)

Page 46: Zebra Direct Sensing MIP-CPT-HPT-LIF

Flow – Zero

Pressure – High

EC – Sand

Case Study - HPT VA Site

Page 47: Zebra Direct Sensing MIP-CPT-HPT-LIF

Case Study - HPT VA Site

Page 48: Zebra Direct Sensing MIP-CPT-HPT-LIF

DAKOTA - UVOST/LIF

UVOST/LIF

Page 49: Zebra Direct Sensing MIP-CPT-HPT-LIF

UVOST/LIF

Page 50: Zebra Direct Sensing MIP-CPT-HPT-LIF

UVOST/LIF

Page 51: Zebra Direct Sensing MIP-CPT-HPT-LIF

UVOST/LIF

Page 52: Zebra Direct Sensing MIP-CPT-HPT-LIF

UVOST/LIF

Page 53: Zebra Direct Sensing MIP-CPT-HPT-LIF

UVOST/LIF

Page 54: Zebra Direct Sensing MIP-CPT-HPT-LIF

UVOST/LIF

Page 55: Zebra Direct Sensing MIP-CPT-HPT-LIF

UVOST/LIF

Page 56: Zebra Direct Sensing MIP-CPT-HPT-LIF

UVOST/LIF

Page 57: Zebra Direct Sensing MIP-CPT-HPT-LIF

UVOST/LIF

Page 58: Zebra Direct Sensing MIP-CPT-HPT-LIF

UVOST/LIF

Page 59: Zebra Direct Sensing MIP-CPT-HPT-LIF

UVOST/LIF

Page 60: Zebra Direct Sensing MIP-CPT-HPT-LIF

UVOST/LIF

Page 61: Zebra Direct Sensing MIP-CPT-HPT-LIF

UVOST/LIF

Page 62: Zebra Direct Sensing MIP-CPT-HPT-LIF

UVOST/LIF

Page 63: Zebra Direct Sensing MIP-CPT-HPT-LIF

UVOST/LIF

Page 64: Zebra Direct Sensing MIP-CPT-HPT-LIF

UVOST/LIF

Page 65: Zebra Direct Sensing MIP-CPT-HPT-LIF

1-800-PROBE-IT

www.TeamZEBRA.com

ZEBRA Environmental Corporation

For more information about the Membrane Interface Probe:

ZEBRA DIRECT SENSING