26
Merchandising Applications The above case model has case lengths that are UL and NSF approved. Issue Date: 12/6/2012 DX6HN -- STRATUS Multi-Deck Capacities Length (FT) Facing Area (FT²) Cubic Capacity (FT³) 4 16.75 48.3 6 25.08 71.6 8 33.46 96.5 12 50.17 143.2 Refrigeration Data BTUH per FT of Case Unlighted Shelves - One Row Canopy - LED Lights BTUH per FT of Case Unlighted Shelves - One Row Canopy - T8 Lights Add BTUH per FT per Row Lighted Shelves Add BTUH per FT per Row Nose Lights or Additional T8 Canopy Light Evap. Temp. Discharge Air Parallel Single Parallel Single LED T8 LED T8 Temp Velocity 1035 1118 1041 1124 11 19 11 19 +28°F +33°F 200-300 FPM Add 13 BTUH/ft for additional LED canopy light Electrical Data Length (FT) ECM Fan Data Shelf Light Amps Per Lighted Shelf Nose Light Amps per Lighted Shelf Canopy Light - Amps Fan Qty Amps LED T8 LED T8 1 Row LED 2 Row T8 4 1 0.10 0.12 0.25 0.10 0.25 0.24 0.50 6 2 0.20 0.09 0.22 0.18 0.44 0.37 0.88 8 2 0.20 0.12 0.25 0.20 0.50 0.48 1.00 12 4 0.40 0.12 0.25 0.36 0.75 0.72 1.50 Defrost Data Defrost Per Day Fail Safe Termination Off Cycle 6 18 min +47°F Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main- tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

DX6HN -- STRATUS Multi-Deck - Kysor Warren Applications The above case model has case lengths that are UL and NSF approved. Issue Date: 12/6/2012 DX6HN -- STRATUS Multi-Deck

Embed Size (px)

Citation preview

Merchandising Applications

The above case model has case lengths that are UL and NSF approved.

Issue Date: 12/6/2012DX6HN -- STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 16.75 48.36 25.08 71.68 33.46 96.512 50.17 143.2

Refrigeration Data

BTUH per FT of Case

Unlighted Shelves - One Row Canopy -

LED Lights

BTUH per FT of Case

Unlighted Shelves -One Row Canopy -

T8 Lights

Add BTUH per FT per Row

Lighted Shelves

Add BTUH per FT per Row

Nose Lights or Additional T8 Canopy

Light

Evap. Temp.

Discharge Air

Parallel Single Parallel Single LED T8 LED T8 Temp Velocity

1035 1118 1041 1124 11 19 11 19 +28°F +33°F 200-300 FPM

Add 13 BTUH/ft for additional LED canopy light

Electrical Data

Length (FT)

ECM Fan DataShelf Light

Amps Per Lighted Shelf

Nose Light Amps per

Lighted Shelf

Canopy Light - Amps

Fan Qty Amps LED T8 LED T8 1 Row LED

2 Row T8

4 1 0.10 0.12 0.25 0.10 0.25 0.24 0.506 2 0.20 0.09 0.22 0.18 0.44 0.37 0.888 2 0.20 0.12 0.25 0.20 0.50 0.48 1.0012 4 0.40 0.12 0.25 0.36 0.75 0.72 1.50

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

A Proud Partner of:

5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com

DX6HN Cross View

Add 3” thickness for a pair of ends.

DX6HN Plan View

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 11/14/2012DX6LC -- STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 17.7 48.36 26.5 71.68 35.4 96.512 53.2 143.2

Refrigeration Data

BTUH per FT of Case

Unlighted Shelves One Row Canopy -

LED Lights

BTUH per FT of Case

Unlighted Shelves One Row Canopy -

T8 Lights

Add BTUH per FT per Row

Lighted Shelves

Add BTUH per FT per Row

Nose Lights or Additional T8 Canopy

Light

Evap. Temp.

Discharge Air

Parallel Single Parallel Single LED T8 LED T8 Temp Velocity

1079 1165 1085 1172 11 19 11 19 +28°F +33°F 200-300 FPM

Electrical Data

Length ECM Fan Data Shelf Light - Amps Per

Lighted Shelf Nose Light - Amps Canopy Light - Amps

Fan Qty Amps LED T8 LED T8 1 Row LED 2 Row T8

4’ 1 0.1 0.12 0.25 N/A N/A 0.24 0.56’ 2 0.2 0.09 0.22 N/A N/A 0.37 0.888’ 2 0.2 0.12 0.25 N/A N/A 0.48 1

12’ 4 0.4 0.12 0.25 N/A N/A 0.72 1.5

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

A Proud Partner of:

5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com

DX6LC Cross View

Add 3” thickness for a pair of ends.

DX6LC Plan View

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 11/14/2012DX6LD -- STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 19.76 49.538 39.48 98.9412 59.2 148.35

Refrigeration Data

BTUH per FT of Case Unlighted Shelves

LED Lights

BTUH per FT of Case Unlighted Shelves

T8 Lights Evap. Temp. Discharge Air

Parallel Single Parallel *Single Temp Velocity 256 276 297 321 +28°F +32°F 185 FPM

BTUH determined using EC Fan Motors.

Electrical Data

Length ECM Fan Data Light - Amps Anti-Sweat (101)

Fan Qty Amps T8 Gelcore LED Optimax Pro Amps4’ 1 0.1 0.96 0.16 0.16 0.618’ 2 0.2 1.44 0.28 0.33 1.2212’ 4 0.4 1.82 0.42 0.48 1.82

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 3 35 min +47°F

Glycol Data

Length Heat Load-BTUH Glycol % PG Supply Temp Temp Rise Flow Rate (GPM) Pressure Drop4’ 1,188 35 +20°F +12°F 0.217 0.30 PSI8’ 2,376 35 +20°F +12°F 0.434 0.30 PSI12’ 3,564 35 +20°F +12°F 0.650 0.30 PSI

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

A Proud Partner of:

5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com

DX6LD Cross View

Add 3” thickness for a pair of ends.

DX6LD Plan View

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 11/14/2012DX6LD-MCU -- STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 19.8 49.58 39.5 98.912 59.2 148.3

Refrigeration Data

BTUH per FT of Case

Unlighted Shelves - One Row Canopy -

LED Lights

BTUH per FT of Case

Unlighted Shelves -One Row Canopy -

T8 Lights

Evap. Temp.

Discharge Air

Parallel Single * Parallel * Single Temp Velocity 256 276 * 297 * 321 +28°F +32°F 185 FPM

BTUH determined using EC Fan Motors.

Electrical Data

Length

ECM Fan Data Light - Amps Anti-Sweat

Condensate Pump *

Condensate Evaporator *

Minimum Circuit

Maximum Overcurrent

Fan Qty Amps * T8LED(Gel-core)

Amps Amps Amps Amps Amps

4’ 1 0.1 * 0.96 0.16 0.64 * 0.44 * 8.30 10.6 158’ 2 0.2 * 1.44 0.28 1.27 * 0.44 * 8.30 11.8 1512’ 4 0.4 * 1.82 0.42 1.82 * 0.44 * 8.30 13 20

Power Supply — 115V / 1 / 60

Length Compressor RLA

Compressor LRA

Condenser Fan Motor

Minimum Circuit

Ampacity

Maximum Overcurrent

Horse Power

4’ 4.2 16.8 0.6 6 10 1/38’ 5.7 24.1 0.7 8 10 1/212’ 5.7 24.1 0.7 8 10 1/2

Power Supply — 208V / 1 / 60

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 3 45 min +47°F

Type I refrigerator, intended for use in an area where the environ-mental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Re-frigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices with-out incurring obligation.

A Proud Partner of:

5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com

DX6LD-MCU Cross View

Add 3” thickness for a pair of ends.

DX6LD-MCU Plan View

DX6LD

- Glycol - M

ulti-Deck

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75 deg F and 55% relative humidity. Kysor/Warren, whose policy is one of continuous improve-ment, reserves the right to change at any time, specifications, design or prices without incurring obligation.

Defrost Per Day Fail Safe Termination

Off Cycle 3 35 min +47°F

Issue: 5.22.2012 Kysor/Warren 5201 Transport Blvd 800-866-5596 phone www.kysorwarren.com Columbus, GA 31907 706-568-8990 fax

Defrost Data

Electrical Data

All electrical data based on 115V and unlighted shelves.

Capacities Length Facing Area (FT²) Cubic Capacity (FT³)

4’ 19.76 49.53

8’ 39.48 98.94

12’ 59.20 148.35

Refrigeration Data

BTUH/ft determined using ECM Fan Motors.

BTUH per FT of Case Unlighted Shelves

LED Lights

* BTUH per FT of CaseUnlighted Shelves

T8 Lights

Evap. Temp.

Discharge Air

Parallel Single * Parallel Single Temp Velocity

256 276 * 297 * 321 +28°F +32°F 185 FPM

Length ECM Fan Data Light - Amps

Fan Qty Amps * T8 Gelcore LED Optimax Pro Amps

4’ 1 0.10 * 0.96 0.16 0.16 0.61

8’ 2 0.20 * 1.44 0.28 0.33 1.22

12’ 4 0.40 * 1.82 0.42 0.48 1.82

Anti-Sweat (101)

The above case model has case lengths that are UL and NSF approved.

Glycol Data

Length Heat Load – BTUH

Glycol % PG Supply Temp (°F) Temp Rise (°F) Flow Rate

(GPM) Pressure

Drop (PSI)

4’ 1,188 35 +20 +12 0.217 0.30

8’ 2,376 35 +20 +12 0.434 0.30

12’ 3,564 35 +20 +12 0.650 0.80

* NOTE: Options are not available after January 1, 2012.

DX6LD

- Glycol - M

ulti-Deck

Add 3” thickness for a pair of ends.

Profile View

Floor Plan

SKIDRAIL

MINIMUM AIR SPACE

LE

G

LE

G

LE

G

LE

G

312 7

2912

48-1/8 (72-1/4)

42

43

29

24 (36)

712

24 (36)

18

512

96-1/4 (144-1/2)

ELECTRICAL ACCESS POINT REFRIGERATION PENETRATION

DRAIN CONNECTION(WITH TRAP RIGHT OR LEFT)

FRONT OF CASE

29STUB UPAREA

STANDARD KICKPLATE LOCATION (PLATINUM)

3

3

3912

35

- STANDARD KICKPLATE LOCATION (MODERN, CLASSIC)- OPTIONAL KICKPLATE LOCATION (PLATINUM)

SKIDRAIL

3

2178

1614

6

42

5958

80

AIR

SP

AC

E

3

4178

3478

29

29278

4234

16

2634

338

62 DOOR

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 11/14/2012DX6LN -- STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 18.7 48.36 28.1 71.68 37.4 96.512 56.2 143.2

Refrigeration Data

BTUH per FT of Case

Unlighted Shelves One Row Canopy -

LED Lights

BTUH per FT of Case

Unlighted Shelves One Row Canopy - T8

Lights

Add BTUH per FT per Row

Lighted Shelves

Add BTUH per FT per Row

Nose Lights or Additional T8 Canopy

Light

Evap. Temp.

Discharge Air

Parallel Single Parallel Single LED T8 LED T8 Temp Velocity

1155 1249 1166 1260 11 19 11 19 +28°F +33°F 200-300 FPM

Add 13 BTUH/FT for additional LED canopy light

Electrical Data

Length ECM Fan Data Shelf Light - Amps Per

Lighted Shelf Nose Light - Amps Canopy Light - Amps

Fan Qty Amps LED T8 LED T8 1 Row LED 2 Row T8

4’ 1 0.1 0.12 0.25 0.1 0.25 0.24 0.56’ 2 0.2 0.09 0.22 0.18 0.44 0.37 0.888’ 2 0.2 0.12 0.25 0.2 0.5 0.48 1

12’ 4 0.4 0.12 0.25 0.36 0.75 0.72 1.5

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min* +47°F

The fail safe time may be extended to a maximum of 28 minutes to allow for store condition variations, refrigeration system variations, and heavy shopping traffic. If the fail safe time is extended, the termination temperature must remain at 47°F.

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

A Proud Partner of:

5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com

DX6LN Cross View

Add 3” thickness for a pair of ends.

DX6LN Plan View

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 6/21/2013DX6LN (Glycol) — STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 18.7 48.3

6 28.1 71.6

8 37.4 96.5

12 56.2 143.2

Refrigeration Data

BTUH per FT of Case

Unlighted Shelves One Row Canopy -

LED Lights

BTUH per FT of Case

Unlighted Shelves One Row Canopy - T8

Lights

Add BTUH per FT per Row

Lighted Shelves

Add BTUH per FT per Row

Nose Lights or Additional T8 Canopy

Light

Evap. Temp.

Discharge Air

Parallel Single Parallel Single LED T8 LED T8 Temp Velocity

1155 1249 1166 1260 11 19 11 19 +28°F +33°F 200-300 FPM

Add 13 BTUH/FT for additional LED canopy light

Electrical Data

Length ECM Fan Data Shelf Light - Amps

Per Lighted ShelfNose Light -

AmpsCanopy Light -

Amps

Qty Amps LED T8 LED T8 1 Row LED

2 Row T8

4’ 1 0.10 0.12 0.25 0.10 0.25 0.24 0.50

6’ 2 0.20 0.09 0.22 0.18 0.44 0.37 0.88

8’ 2 0.20 0.12 0.25 0.20 0.50 0.48 1.00

12’ 4 0.40 0.12 0.25 0.36 0.75 0.72 1.5

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 6 35 min* +47°F

Glycol Data

Length Heat Load – BTUH

Glycol % PG

Supply Temp (°F)

Temp Rise (°F)

Flow Rate (GPM)

Pressure Drop (PSI)

4’ 4,644 35 +22 +12 0.847 1.20

6’ 6,966 35 +22 +12 1.271 2.70

8’ 9,288 35 +22 +12 1.694 1.20

12’ 13,932 35 +22 +12 2.542 2.70

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained that condi-tions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improve-ment, reserves the right to change at any time specifications, designs, or prices with-out incurring obligation.

The fail safe time may be extended to a maximum of 45 minutes to allow for store condition variations, refrigeration system varia-tions, and heavy shopping traffic. If the fail safe time is extended, the termination temperature must remain at 47°F.

A Proud Partner of: 5201 Transport Blvd. • Columbus, GA 31907Toll-Free: 800.866.5596 • Phone: 706.568.1514heatcraftrpd.com

DX6LN Cross View

Add 3 1/2” thickness for a pair of ends.

DX6LN Plan View

Merchandising Applications

The above case model has case lengths that are UL and NSF approved.

Issue Date: 12/6/2012DX6LP -- STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 17.7 48.36 26.5 71.68 35.4 96.512 53.2 143.2

Refrigeration Data

BTUH per FT of Case

Unlighted Shelves - One Row Canopy -

LED Lights

BTUH per FT of Case

Unlighted Shelves -One Row Canopy -

T8 Lights

Add BTUH per FT per Row

Lighted Shelves

Add BTUH per FT per Row

Nose Lights or Additional T8 Canopy Light

Evap. Temp.

Discharge Air

Parallel Single Parallel Single LED T8 LED T8 Temp Velocity 1079 1165 1085 1172 11 19 11 19 +28°F +33°F 200-300 FPM

Add 13 BTUH/FT for additional LED canopy light

Electrical Data

Length (FT)

ECM Fan DataShelf Light

Amps Per Lighted Shelf

Nose Light Amps per

Lighted Shelf

Canopy Light - Amps

Fan Qty Amps LED T8 LED T8 1 Row LED

2 Row T8

4 1 0.10 0.12 0.25 N/A N/A 0.24 0.506 2 0.20 0.09 0.22 N/A N/A 0.37 0.888 2 0.20 0.12 0.25 N/A N/A 0.48 1.0012 4 0.40 0.12 0.25 N/A N/A 0.72 1.50

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

A Proud Partner of:

5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com

DX6LP Cross View

Add 3” thickness for a pair of ends.

DX6LP Plan View

Merchandising Applications

The above case model has case lengths that are UL and NSF approved.

Issue Date: 12/6/2012DX6LP (T5) -- STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 17.7 48.36 26.5 71.68 35.4 96.512 53.2 143.2

Refrigeration Data

BTUH per FT of Case

Unlighted Shelves - One Row Canopy -

LED Lights

BTUH per FT of Case

Unlighted Shelves -One Row Canopy -

T8 Lights

Add BTUH per FT per Row

Lighted Shelves

Add BTUH per FT per Row

Nose Lights or Additional T8 Canopy Light

Evap. Temp.

Discharge Air

Parallel Single Parallel Single LED T8 LED T8 Temp Velocity 1079 1165 1085 1172 11 19 11 19 +28°F +33°F 200-300 FPM

BTUH per FT of Case Unlighted Shelves -

One Row Canopy - Standard T5

BTUH per FT of Case Unlighted Shelves -

One Row Canopy - High Output T5Parallel Single Parallel Single1090 1178 1109 1198

Add 13 BTUH/FT for additional LED canopy light

Electrical Data

Length (FT)

ECM Fan DataShelf Light

Amps Per Lighted Shelf

Nose Light Amps per

Lighted Shelf

Canopy Light - Amps Canopy Light - Amps

Fan Qty Amps LED T8 LED T8 1 Row LED

2 Row T8

1 Row Stan-dard T5

1 Row High Output T5

4 1 0.10 0.12 0.25 0.10 0.25 0.24 0.50 0.23 0.456 2 0.20 0.09 0.22 0.18 0.44 0.37 0.88 0.35 0.658 2 0.20 0.12 0.25 0.20 0.50 0.48 1.00 0.46 0.9012 4 0.40 0.12 0.25 0.36 0.75 0.72 1.50 0.69 1.35

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

A Proud Partner of:

5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com

DX6LP Cross View

Add 3” thickness for a pair of ends.

DX6LP Plan View

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 11/14/2012DX6UD -- STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 19.76 49.538 39.48 98.9412 59.2 148.35

Refrigeration Data

BTUH per FT of Case Unlighted Shelves

LED Lights

BTUH per FT of Case Unlighted Shelves

T8 Lights Evap. Temp. Discharge Air

Parallel Single Parallel Single Temp Velocity 256 276 297 321 +28°F +32°F 185 FPM

BTUH determined using EC Fan Motors.

Electrical Data

Length ECM Fan Data Light - Amps Anti-Sweat (101)

Fan Qty Amps T8 Gelcore LED Optimax Pro Amps4’ 1 0.1 0.96 0.16 0.16 0.618’ 2 0.2 1.44 0.28 0.33 1.2212’ 4 0.4 1.82 0.42 0.48 1.82

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 3 35 min +47°F

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

A Proud Partner of:

5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com

DX6UD Cross View

Add 3” thickness for a pair of ends.

DX6UD Plan View

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 11/14/2012DX6UN -- STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 19.76 48.36 29.6 71.68 39.48 96.512 59.2 143.2

Refrigeration Data

BTUH per FT of Case

Unlighted Shelves - One Row Canopy -

LED Lights

BTUH per FT of Case

Unlighted Shelves -One Row Canopy -

T8 Lights

Add BTUH per FT per Row

Lighted Shelves

Add BTUH per FT per Row

Nose Lights or Additional T8 Canopy

Light

Evap. Temp.

Discharge Air

Parallel Single Parallel Single LED T8 LED T8 Temp Velocity

1201 1297 1207 1304 11 19 11 19 +26°F +33°F 200-300 FPM

Add 13 BTUH/FT for additional LED canopy light

Electrical Data

Length ECM Fan Data

Shelf Light Amps Per

Lighted Shelf

Canopy Light - Amps

Fan Qty Amps LED T8 1 Row LED

2 Row T8

4’ 1 0.1 0.12 0.25 0.24 0.56’ 2 0.2 0.09 0.22 0.37 0.888’ 2 0.2 0.12 0.25 0.48 112’ 4 0.4 0.12 0.25 0.72 1.5

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

A Proud Partner of:

5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com

DX6UN Cross View

Add 3” thickness for a pair of ends.

DX6UN Plan View

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 11/14/2012DX6XN -- STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 17.7 48.36 26.5 71.68 35.4 96.5

12 53.2 143.2

Refrigeration Data

BTUH per FT of Case

Unlighted ShelvesOne Row Canopy -

LED Lights

BTUH per FT of Case

Unlighted ShelvesOne Row Canopy - T8

Lights

Add BTUH per FT per Row

Lighted Shelves

Add BTUH per FT per Row

Nose Lights or Additional T8 Canopy

Light

Evap. Temp.

Discharge Air

Parallel Single Parallel Single LED T8 LED T8 Temp Velocity

1079 1165 1085 1172 11 19 11 19 +28°F +33°F 200-300 FPM

Add 13 BTUH/FT for additional LED canopy light

Electrical Data

Length ECM Fan Data Shelf Light - Amps Per

Lighted Shelf Nose Light - Amps Canopy Light - Amps

Fan Qty Amps LED T8 LED T8 1 Row LED 2 Row T8

4’ 1 0.1 0.12 0.25 0.1 0.25 0.24 0.56’ 2 0.2 0.09 0.22 0.18 0.44 0.37 0.888’ 2 0.2 0.12 0.25 0.2 0.55 0.48 1

12’ 4 0.4 0.12 0.25 0.36 0.75 0.72 1.5

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F

The fail safe time may be extended to a maximum of 28 minutes to allow for store condition varia-tions, refrigeration system variations, and heavy shopping traffic. If the fail safe time is extended, the termina-tion temperature must remain at 47°F.

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

A Proud Partner of:

5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com

DX6XN Cross View

Add 3” thickness for a pair of ends.

DX6XN Plan View

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 6/21/2013DX6XN (Glycol) — STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 17.7 48.3

6 26.5 71.6

8 35.4 96.5

12 53.2 143.2

Refrigeration Data

BTUH per FT of Case

Unlighted Shelves One Row Canopy -

LED Lights

BTUH per FT of Case

Unlighted Shelves One Row Canopy - T8

Lights

Add BTUH per FT per Row Lighted

Shelves

Add BTUH per FT per Row

Nose Lights or Additional T8 Canopy Light

Evap. Temp.

Discharge Air

Parallel Single Parallel Single LED T8 LED T8 Temp Velocity

1079 1165 1085 1172 11 19 11 19 +28°F +33°F 200-300 FPM

Add 13 BTUH/FT for additional LED canopy light

Electrical Data

Length ECM Fan Data Shelf Light - Amps Per

Lighted Shelf Nose Light - Amps Canopy Light - Amps

Fan Qty Amps LED T8 LED T8 1 Row LED 2 Row T8

4’ 1 0.10 0.12 0.25 0.10 0.25 0.24 0.50

6’ 2 0.20 0.09 0.22 0.18 0.44 0.37 0.88

8’ 2 0.20 0.12 0.25 0.20 0.55 0.48 1.00

12’ 4 0.40 0.12 0.25 0.36 0.75 0.72 1.5

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 6 35 min +47°F

Glycol Data

Length Heat Load – BTUH

Glycol % PG

Supply Temp (°F)

Temp Rise (°F)

Flow Rate (GPM)

Pressure Drop (PSI)

4’ 4,360 35 +22 +12 0.796 1.20

6’ 6,540 35 +22 +12 1.193 2.60

8’ 8,720 35 +22 +12 1.592 1.20

12’ 13,080 35 +22 +12 2.386 2.60

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained that condi-tions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improve-ment, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

The fail safe time may be extended to a maximum of 45 min-utes to allow for store condition variations, refrigeration system variations, and heavy shopping traffic. If the fail safe time is extended, the termination temperature must remain at 47°F.

A Proud Partner of: 5201 Transport Blvd. • Columbus, GA 31907Toll-Free: 800.866.5596 • Phone: 706.568.1514heatcraftrpd.com

DX6XN Cross View

Add 3 1/2” thickness for a pair of ends.

DX6XN Plan View