LRZE………………………………………………………………………LRZM……………………………………………………………………..LXi ………………………………………………………………………..LITE 2 LD ………………………………………………………………..LITE 2 LJ ………………………………………………………………..LITE 2 LG ……………………………………………………………….LX or LT STANDARD BURNERS ……………………………………LX or LT LOW NOx BURNERS ……………………………………….HiE2 ………………………………………………………………………SERIES 1 & 2 SPARK IGNITION …………………………………….SERIES 1 & 2 MILLIVOLT …………………………………………….HOT SHOT (100 K) ..…………………………………………………..DP OIL FIRED ………………………………………………………….
2, 34, 56, 78, 910, 1112, 1314, 1516, 1718, 19202122, 2324
Heater Troubleshooting Guides
Table Of Contents
1
F
STEP 2 – Check Transformer
24 VAC between Red (2) wire and Yellow (1) wire on Transformer?
YES
NO Replace Transformer
STEP 1 – Check in coming power (make certain filter pump motor is ON).
240 or 120 VAC between Black (A) wire and Red (B) wire?
YES
NO Make certain filter pump is on. Correct wiring.
STEP 3 – Check Fuse
24 VAC between Red (3) wire on PIB and Yellow (1) wire on Transformer?
NO Locate and correct short circuit, replace Fuse.
YES
STEP 4 – Check power to Water Press. Sw.
24 VAC between Purple (4) wire on PIB and Yellow (1) wire on Transformer?
NO Recheck voltage at Red (3) wire. If voltage is 24 VAC replace PIB.
STEP 5 – Check thru Water Press. Sw.
24 VAC between Gray (5) wire on PIB and Yellow (1) wire on Transformer?
NO
Do a Back Pressure Test. If pressure is higher than 2 PSI, replace Water Pressure Switch. If less, clean filter, baskets or repair pressure problem.
YES
STEP 6 – Check thru Vent Temp Limit
24 VAC between Orange (6) wire after Vent Temp Limit and Yellow (1) wire on Transformer?
NO Correct blockage in vent. Replace Vent Temp Limit
YES
STEP 7 – Check thru Fusible Link
24 VAC between Blue (7) wire on PIB and Yellow (1) wire on Transformer?
NO Check wires to Fusible Link, replace Fusible Link. Correct excessive heat problem in cabinet. Possible rollout.
YES
STEP 8 – Check power to High Limits
24 VAC between Black (8) wire on PIB and Yellow (1) wire on Transformer?
NO Recheck power at Blue (7) wire. If 24 VAC at Blue but not Black, replace PIB.
STEP 9 – Check thru High Limits
24 VAC between Black (9) wire on PIB and Yellow (1) wire on Transformer?
NO Replace both High Limits. Do a Temp. Rise Test. Correct flow problem.
YES
Make certain control is calling for heat.
24 VAC between Black/Yellow (10) wire on PIB at J3 and Yellow (1) wire on Transformer?
NO
STEP 10 – Check power to Ignition Control YES
Recheck power at Black (9) wire. If 24 VAC at Black, but not Black/Yellow (10), replace PIB.
24 VAC between Black/Yellow (11) at W terminal of Ignition Control and Yellow (1) wire of Transformer?
NO
STEP 11 – Check power at Ignition Control
YES
Correct problem with Black/Yellow wire or its connectors.
YES
YES
STEP 13 – Go to back page
Is Igniter (12) glowing?
NO STEP 12 – Check Hot Surface Igniter (Igniter)
Turn heater OFF. Disconnect Igniter at C & D. Turn heater ON. Check voltage in the connector ends of C & D going to the Ignition Control (not to the Igniter). If your meter is a true RMS meter the voltage should read 105 to 130 VAC. If your meter is not a true RMS meter the voltage should read 64 to 130 VAC. If the voltage is within range replace the Igniter. If the voltage is low recheck incoming power. If the voltage is above 130 VAC replace both the Igniter and Ignition Control.
YES
LRZE TROUBLESHOOTING
Make certain Universal Control is calling for heat (red LED on).
Power Interface Board (PIB)
J15
J16
J17
J 6
24 VAC COMP/
IGN PUMP FAN/
LOUVER
L1
W
VAL
GND
IGN/
FS
24
VAC
FC IGN/
120
L2
Ignition Control
IGN/
240
Purple
Gray
Orange
Blue
Black
Black
Yellow
Black/Yellow
Red
Brown
Yellow
Red
Black/Yellow
Black
Black
White
White
Red
Bla
ck
Whi
te
Brown
Yellow
3
Transformer
Fuse 250 V – 2 amp
Gas Valve
Hot Surface Igniter
Flame Sensor
Burner
Pressure Switch
Fusible Link 305 °F
High Limits
Universal Control
5
7 8
9
10
A B
C
D 14
Red/White
Black/White
J 3
J12
4
120 or 240 VAC Power Supply
J 9 H2O
11
13
Brown
12
Water Temperature Sensor
Valve Monitor Circuit
15
Diagnostic LED
1
2
Red
150 ºF (red dot)
130 ºF
Black
Vent Temp Limit 464 °F
Red Marking
Blue 6
After the Igniter begins to glow, wait approximately 40 seconds. Did the burners ignite?
NOSTEP 13 – Check for Ignition
Check voltage between Brown (13) wire at Gas Valve and Yellow (1) wire of transformer. Is there 24 VAC?NO
Check voltage at VAL of Ignition Control. If 24 VAC, replace brown wire. If no voltage replace Ignition Control.
Do Burners stay on past 7 seconds? NOSTEP 14 – Check Burners operation
YES
Heater is not recognizing the flame (flame rectification). Any of the following can prevent flame rectification:• Low gas pressure.• Plugged burner orifice.• Poorly connected or missing ground wire. • Corroded or dirty Flame Sense Rod.• Ignition Control not receiving flame sense signal.Or there is insufficient current when the gas valve is powered. Current loss can be caused by any of the following:• Excessive corrosion on wire terminals.• Frayed or over heated wires.• Pitting of contact points of the Water Pressure Switch or corrosion on connectors of the High Limits.To determine whether the problem is lack of rectification or loss of current, check voltage at the Black/Yellow (11) wire at the Ignition Control. Keep the meter probe at this location and watch the reading. If, after the gas valve receives power, the voltage slowly drops until the gas valve shuts off, then returns to normal, the problem is due to loss of current.
YES
YES
Check supply gas pressure (see chart below). Did burners ignite?
YES NO
Check manifold pressure (see chart below). If supply was correct but there is no pressure on manifold replace the Gas Valve. If pressure is high check for plugged or wrong orifices. If pressure exists but is low correct supply problem.
LRZE TROUBLESHOOTING
STEP 15 – Check Burners operationDo Burners stay on past 5 minutes?
YES NO
24 VAC between Brown (15) and Yellow (1) wires?
DISPLAY FAULT CAUSE
Display showsNO FLOW
FAULT-HIGH LIMIT
FAULT-FUSELINK/FIELD
FAULT-CHECK IGN CONTROL
1. Pump is not running.
2. Low pump pressure.
3. Pressure switch fault.
1. Water temperature in heaterexceeds the internal limit.
2. Limit switch fault.
1. Fusible link fault.
1. Air flow restricted at intake ordischarge.
2. Oscillating pump pressure.
3. Low gas supply pressure.
4. No flame at burners.
FAULT-SHORTED H20 SENSORORFAULT-OPEN WATER SENSOR
1. Faulty wiring or connection.
2. Faulty sensor.
5. Check Ignition Control LED.
REMEDY1. This is normal display when the pump is OFF. No service
required.2. Clean filter or clear blockage, check position of valves
in plumbing system.3. Adjust or replace pressure switch.
1. Verify function of high limit switches. Perform Temperature Rise Test (see chart below). Identify and correct cause of overheating.
2. Identify and correct loose connections or replace switches.
1. Identify and correct loose connections or replace Fusible Link.
1. Check for proper clearances around heater and for adequate room ventilation if enclosed. Inspect for blockage or restrictionat discharge of flue.
2. Clean filter or identify and repair cause of pump oscillation.
3. Identify and repair incorrect supply pipe size or pipe line blockage.
4. Identify and correct loose wiring connections, or problemwith Igniter. Flame Sensor, Gas Valve or Ignition Control.
5. If the LED is on continuously, replace the ignition control. If the LED is blinking, check for causes of the unrecognized flame.
1. Inspect Sensor wiring. Ensure Sensor is connected intoPower Interface Board (PIB).
2. Inspect Sensor wires. Replace Temperature Sensor.
Blue
Yellow
Heater is operating.
Fault Codes
Recheck gas pressure, burner orifices and air supply (see manual for more details).
Temperature Rise Chart
Go back to Step 13.
YES NO
Replace PIB.
Does flame look blue or yellow?
Gas PressureChart
Set gas valve knob to the Pilot position. Set thermostat
rocker switch to OFF. Set meter to VDC above one.
Does pilot light? 1. Verify gas is on. 2. Check for air in gas line. 3. Check for clogged pilot tube or orifice.
Does pilot stay on when gas valve knob is released?
1. Check P/G output. 2. Check for shorted wires. 3. Check pilot coil (yellow wires).
STEP 1 – Try to light pilot
STEP 2 – Check pilot operation
STEP 3 – Check pilot output
Is there 500+ mV between PP and PP-TH terminals?
1. Check for low Pilot Generator output. 2. Check for partial shorts or loose wires. 3. Replace Pilot Generator.
For the following tests leave the Red probe on the PP terminal.
Move the Black probe to each test position.
STEP 4 – Check Fusible Link
Is there 500+ mV through Fusible Link?
Replace Fusible Link. Check for Roll out, Soot, Down drafting,
Low Gas Pressure, etc.
STEP 6 – Check Fireman’s Switch
Is there 500+ mV through Fireman’s Switch?
STEP 7 – Check High Limits
Is there 500+ mV through at White wire of Pressure Switch?
Check that a control system (if installed) is calling for heat or Fireman’s Switch
loop is closed.
Check wire harness to High Limits for damage, if OK replace both High Limit. Check for damage to by pass disc,
headers, or exchanger.
Do a Temperature Rise Test.
Is there 500+ mV @ Black Wire of Pressure Switch?
Make certain filter pump is ON. Perform Back Pressure Test. If 2.5 PSI or more, replace switch. If less, check pump, filter, etc. for pressure problem.
Set rocker switch to ON. Set thermostat to maximum.
Is there 200+ mV @ Black wire of Temp. Board on terminal TH/PP?
Is there 200+ mV @ TH terminal of the Gas Valve?
500+ mV do the tests below .
Move rocker switch to OFF. Rotate Gas Valve Knob to ON. Move rocker switch to ON. Does heater fire?
Check #1 burner and orifice. Check gas pressure. If all OK replace Gas Valve.
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
STEP 8 – Check Pressure Switch
NO
YES
NO
YES
STEP 9 – Check Thermostat
YES
NO
NO STEP 10 – Check Gas Valve
Pressure Switch
Thermistor
Pilot Generator
Fusible Link 305 °F
Gas Valve
Fireman’s Switch Connection
AquaLink RS
TH
Hi-Limit 150º F
(red dot) Hi-Limit 130º F
Temperature Control
Thermostat
Jandy
MIN MAX
Rocker Switch
PP-TH PP
1
2
3
5
6 7 8
YES
9
Wires to control or fireman’s switch. Minimum wire size: 14 AWG, 105º C Maximum length: 10 to 15 feet.
Zero volts - Replace rocker switch.
LRZM TROUBLESHOOTING
SEN SEN POT POT
TH/PP +
(PP) Valve (TH)
Temperature Board
10
RED
WHITE
WHITE
WHITE
WHITE WHITE WHITE
BLACK
ORANGE
To dissipate excess current, the LED will flash approximately every 7 seconds when the heater is enabled but the thermostat setting has been satisfied. If the LED does not flash, try reversing the Generator leads at the Gas Valve.
Coil wires
Perform Thermistor Test (see back pg.)
Disconnect pot wires (orange) and jump pot terminals. If voltage drops to 200+ mV, replace Temp. Control.
Replace Temp. Board
After correcting problem return to Step 9 and proceed.
Vent Temp Limit 464 °F
Red Marking
STEP 5 – Check Vent Temp Limit
Is there 500+ mV through Vent Temp Limit?
Check for blockage in the vent. Replace Vent Temp Limit.
NO
YES
4
Total Millivolt (mV) Loss TestAfter the heater is completely operational and firing, do a Total Millivolt Loss Test by place one meter probe on PP-TH and the other probe on TH of the Gas Valve. The meter will now read the total millivolts lost in the entire circuit. Maximum allowable loss for the LRZM is 80 mV. If the loss is greater than 80 mV, test each wire and component by placing one probe at one end and the other probe at the other end of each item. Ideally all wires should have a zero reading and each component, except the Rocker Switch and Temperature Board should have no more than a 5 mV loss. The Rocker Switch can have up to 10 mV and the Temperature Board up to 50 mV. Any item which shows higher than allowable loss should be cleaned, repaired or replaced.
Temperature Rise Chart Thermistor (Water Temperature Sensor) Chart
50 (10)60 (15)70 (21)80 (26)90 (32)
100 (38)
WATER TEMP INHEADER ºF (ºC)
APPROX. RESISTANCE IN 1,000’SOF OHMS (kOhms)
19.915.311.9
9.37.35.8
Gas Pressure Chart
Supply Pressure
Natural Gas
LP Gas
Manifold PressureNatural GasLP Gas
Minimum5.5 Inches WC(1.4 kPa)
10.0 Inches WC(2.5 kPa)Nominal4.0 Inches WC (1.0 kPa)
9.0 Inches WC (2.2 kPa)
Maximum10.0 Inches WC(2.5 kPa)
14.0 Inches WC(3.5 kPa)
Symptom Cause Remedy
Pump not operating.
Pilot outage.
Flame roll-out at startup.
Spillage at draft hood.
Lazy flame with yellow tip.
Not enough heat
Heater pounding or knocking.
Heater condensing
Pressure relief valve opens.
Pilot is lit but main burners will not come on.
Heater short cycles
A. No powerB. Pump defectiveC. Incorrect wiring
A. Inlet gas pressure low
B. Inlet gas pressure too high causingan unstable blowing pilot.
C. Weak or defective thermocouple.D. Damaged pilot or thermocoupleE. Dirty pilotF. Plugged or undersized pilot orifice.
A. Check burner orifices for blockage (spider webs)
B. Blocked flueC. Pilot out of position (delayed ignition)D. Blocked heat exchanger.E. Fiber board out of place.F. Altered vent cap.G. Low gas pressure
A. Cold chimneyB. Vent pipe pitches down to chimneyC. Blocked chimney.D. Altered draft hood.E. Prefabricated chimney with incorrect cap.
A. Inadequate water flow through heater.
A. Low water temperature.
A. Restriction in water flow system at or downstream of heater
A. Gas valve not at “ON” position.B. Hi-Limit switches failed.C. Pressure switch failed or out of adjustment.D. Fusible Link failed.E. Gas valve failed.F. Broken wire in thermostat circuit or
defective thermostat.G. Heater wired incorrectly.
A. Low water flow through heater.B. Failed High-limit switch.
A. Check circuit breaker and power.B. Replace.C. Recheck wiring.
A. Consult gas utility company. Inlet gas pressure to heater should be 5.5” to 10.0” WC for Natural Gas or 10.0” to 14” for Propane Gas.
B. Pressure should be regulated within limits shown above.
C. Replace thermocouple.D. Replace.E. Blow dust or lint out of pilot.F. Clean or replace pilot orifice.
A. Remove and clean each orifice.
B. Remove blockage.C. Correct pilot position.D. Clean or correct as necessary.E. Clean or correct fiber board as necessary.F. Install factory provided vent cap.G. Check and correct gas pressure.
A. Allow heater to operate five (5) minutes to create draft action.B. Reinstall vent cap to pitch up from heater to chimney.C. Remove blockage.D. Install factory provided draft hood.E. Install UL listed vent cap.
A. Check for blocked louvers or openings to heater.
A. Gas meter too small. Gas line from meter to heater too small.B. Gas pressure on heater manifold should be adjusted to 4.0” WC Natural
Gas, 9.0” WC Propane.C. Replace with heater of higher input rating.D. Check and correct water flow.
A. Check Temperature Rise (see chart above). If temperature rise is above the maximum check for damaged or incorrectly set bypass.
A. Flue product moisture will condense at the start-up until the water temperature reaches normal operating conditions.
A. Check for proper operation of all valves, bypass valve and any equipment between pool and heater outlet.
A. Turn knob to “ON” position.B. Investigate reason for overheating and replace Hi-limit switches.C. Adjust pressure switch or replace as necessary.D. Investigate reason for flame rollout and replace Fusible link as necessary.E. Check and replace Gas Valve as necessary.F. Check continuity through thermostat circuit with wires disconnected.
G. Check heater wiring against wiring diagram.
A. Increase size of pump or increase piping size as necessary.B. Check Hi-limit switches and replace as necessary.
A. Low primary air.
A. Inadequate gas supplyB. Low manifold gas pressure.
C. Heater size inadequate.D. Low Temperature Rise.
LRZM TROUBLESHOOTING
5
STEP 2 – Check Transformer
24 VAC between Red (2) wire
and Yellow (1) wire on Transformer?
YES
NO
If wired 240 VAC check voltage
between Black (E)
wire and Blue (F) wire. If wired
120 VAC check voltage between
Black (E) and White (D) wires. If
the correct voltage is present,
replace Transformer, if not check
Conversion Board position.
STEP 1 – Check Power at Dist. Brd. (make certain filter pump motor is ON).
240 or 120 VAC between Black (C) wire
and Red (B) wire on Power Dist. Brd.?
YES
NOMake certain filter pump is on.
Correct wiring.
STEP 3 – Check Fuse
24 VAC between Red (3) wire on PIB
and Yellow (1) wire on Transformer?
NOLocate and correct short circuit,
replace Fuse.
YES
STEP 4 – Check power to Water Press. Sw.
24 VAC between Purple (4) wire on PIB
and Yellow (1) wire on Transformer?
NO Recheck voltage at Red (3)
wire, if voltage is 24 VAC
replace PIB.
STEP 5 – Check Water Pressure Switch
24 VAC between Gray (5) wire on PIB
and Yellow (1) wire on Transformer?NO
Do a Back Pressure Test, if
pressure is higher than 2 PSI,
replace Water Pressure Switch,
if less clean filter, baskets or
repair pressure problem.
YES
STEP 6 – Check power to Fusible Link
24 VAC between Orange (6) wire on PIB
and Yellow (1) wire on Transformer?
NO Recheck voltage at Gray (5)
wire, if voltage is 24 VAC
replace PIB.
YES
STEP 7 – Check Fusible Link
24 VAC between Blue (7) wire on PIB
and Yellow (1) wire on Transformer?NO
Check Fusible Link Air Box and ,
Vent Temp Limit individually.
Replace failed part.
Correct excessive heat problem
in vent or air box.
YES
STEP 8 – Check power to High Limits
24 VAC between Black (8) wire on PIB
and Yellow (1) wire on Transformer?NO
Recheck power at Blue (7)
wire. If 24 VAC at Blue
but not Black, replace PIB.
STEP 9 – Check High Limits
24 VAC between Black (9) wire on PIB
and Yellow (1) wire on Transformer?
NO Replace both High Limits.
Do a Temp. Rise Test.
YES
24 VAC between Black/Yellow (10)
wire on PIB and Yellow (1) wire on
Transformer?
NO
STEP 10 – Check power to Ignition Control
YES
Recheck power at Black (9)
wire. If 24 VAC at Black, but
not Black/Yellow (10),
replace PIB.
YES
24 VAC between Black/Yellow (11) at
W terminal of Ignition Control and
Yellow of Transformer?
NO
STEP 11 – Check power at Ignition Control
YES
Correct problem with
Black/Yellow wire or its
connectors.
YES
Note: If Blower is ON, go to Step 13 on back page.
Is Blower ON?NO
STEP 12 – Check Blower
YESCheck voltage between F2 terminal of Ignition
Control and ground (A). Is voltage 105 VAC or
higher?
STEP 13 – Go to back page
NO YES
Correct incoming
power problem.
Check voltage between F1 terminal
of Ignition Control and ground (A).
Is voltage 105 VAC or higher? If no,
replace Ignition Control, if yes
check voltage between Black(L)
wire to Blower on PDB and ground
(A). If voltage is 105 VAC or higher
replace Blower, if lower check
wires, replace PDB
YES
LXi Troubleshooting Guide — Serial Number G11LB0001 or newer
After Blower comes on wait at least 15 seconds (Pre-Purge).
Is Igniter glowing?
NO
STEP 15 – Check Hot Surface IgniterCheck voltage between K and J of the Ignition Control. If 105 to 130 VAC, check wires and
connectors to the Igniter, if OK, replace Igniter. If voltage is less than 105 VAC check
incoming voltage between L1 and L2, if voltage is 105 to 130 VAC replace Ignition Control.
After the HSI begins to glow, wait
approximately 40 seconds. Did the burners ignite?
NOSTEP 16 – Check for Ignition
YES
Check voltage on Brown (13) wire at terminal VAL of the Ignition Control. Is there 24 VAC at VAL?
NO
Replace Ignition
Control.
YES
Check supply gas pressure. If
OK, replace Gas Valve.
Do Burners stay on beyond 7
seconds?
NO
STEP 17 – Check Burners operation
YES
Heater is not recognizing the flame (flame rectification). Any of the following can prevent flame rectification:
• Low gas pressure.
• Poorly connected or missing ground wire.
• Corroded or dirty Flame Sense Rod.
• Ignition Control not sending flame sense signal.
Or there is insufficient current when the gas valve is powered. Current loss can be caused by any of the following:
• Excessive corrosion on wire terminals.
• Frayed or over heated wires.
• Pitting of contact points, usually at the Water Pressure Switch or High Limits.
To determine whether the problem is lack of rectification or loss of current, check voltage at the Black/Yellow (11)
wire at the Ignition Control. Keep the meter probe at this location and watch the reading. If, after the gas valve
receives power, the voltage slowly drops until the gas valve shuts off, then returns to normal, the problem is due to
loss of current.
YES
Heater is operating.
Blower is ON – See Note below.
24 VAC between Orange (NO) wire at the Air Pressure Switch
and Yellow (1) wire on Transformer?NO
STEP 13 – Check Air Pressure Switch Make certain Blower is on and combustion chamber is sealed. Check air tubes for kinks
or holes. Make certain front air tube is connected to the positive (+) side and back/lower
air tube is connected to negative (-) side of the Air Pressure Switch. If all are OK replace
the Air Pressure Switch.
YES
24 VAC between Orange (12) wire at the Ignition Control and
Yellow (1) wire on Transformer?
NO
STEP 14 – Check Power to PSW
Check wire connections. Replace Orange wire.
YES
Note: If the blower runs continuously, unplug F1/F2 connector from the Ignition Control, if the blower goes off replace the Ignition
Control. If the blower stays on, check for shorted wires between the Ignition Control and PDB or from the PDB and the Blower.
Service Codes
TEMPERATURE RISE
MODEL 250
Serial # A & B
Serial # C & Newer
MODEL 300
Serial # A & B
Serial # C & Newer
MODEL 400
Serial # A & B
Serial # C & Newer
MIN. MAX.
7 °F 10 °F
8 °F 12 °F
MIN. MAX.
8 °F 11 °F
11 °F 18 °F
MIN. MAX.
13 °F 17 °F
14 °F 21 °F
GAS PRESSUREInches of Water Column
Manifold
Supply
Natural LP
2.5 9.0
5.5 to 10.5 11 to 14
LXi Troubleshooting Guide — Serial Number G11LB0001 or newer
1) Check incoming Power Supply.2) Check Transformer Wiring.3) Replace Transformer.
STEP 1
24 VAC atTransformer
YES
YES
NO
NO24 VAC at RedWire of Fuse
Link?
Fuse is blown. Look for short oroverload of controls. Do notjumper or bypass. Fuse protectstransformer.
24 VAC atWhite Wire of
Fuse Link?
STEP 2
STEP 3
24 VAC atboth Fireman
Switch terminal’s
YES
NO
STEP 3a
STEP 4YES
24 VAC atWhite Wire of
Pressure Switch?
STEP 5
YES
24 VAC atBlack Wire of
Pressure Switch?
NO
NO
NO
Too much heat in control area.Look for down drafting, Roll-out,Soot, or Low Gas Pressure.Replace Fuse Link.
Check that a control system (ifinstalled) is calling for heat orthe Fireman’s Switch is closed.
1) Check each limit individually.4a & 4b2) Check if damage to disc,heads, or exchanger.3) Take Temperature Rise.
Perform back pressure test.If 2 PSI or more, replaceswitch. If less, check pump,filter, etc., for water flowproblems.
YES
STEP 6
STEP 9
STEP 8
STEP 7
YES
NO
NO
Do a Thermistor Test.Is thermistor withinrange? See chart onback page.
24 VAC atBlack/Yellow wire
at the IND ofIgnition Control?
Is temperature Board calling for heat?YES
NO
YES
ReplaceThermistor
Replace Temp.Board.
24 VAC at the Blackwire at TH of theIgnition Control
YES
Replace Ignition Control.Check wire connectors.
NO24 VAC at VALof the IgnitionControl?
Remember, the VAL terminal will only havepower for 7 seconds after the Ignitor hasheated for 35 seconds. If there is never 24VAC at the VAL, even after the Ignitor hasheated and shut down, replace the IgnitionControl.
YES
Does heaterfire?
NOOK
Replace GasValve.
Verify Ignitor wiring.Are all gas valvesopen? Is gaspressure correct?
Remove the connector at F1 & F2of the Ignition Control. Perform acontinuity test between F1 & F2terminals on the Ignition Control.Is there continuity?
NOYES
Wait for 15second delay.
Does Ignitorheat up?
1. Is Ignition Control wired for proper voltage?2. Is Ignitor properly connected?3. Do Ignitor Test. Is Ignitor within range?
YES
Replace Ignition Control. Replace Ignitor.
NOYES
NO
IGN 240IGN 120L1
L2
IGN/FSTHINDVALGND
FENWAL DIGITALIGNITION CONTROL
6
F1F2
24 VACFC
Fireman’sSwitch
ConnectionFusible
Link
Hot Surface Ignitor
RedRed
Gas Valve
Thermistor
MVMV
AquaLink RS
Transformer 240 VAC240 VAC
WhiteWhite
WhiteWhite
PressureSwitch
BlackBlack
YellowYellow
BlackBlack
Temperature Control
BrownBrown
Flame Proving Rod
White/BlackWhite/Black
White/RedWhite/Red
Hi-Limit 150° F (red dot)
Hi-Limit 135° F
RedRed
Yellow
/Gree
n
Yellow
/Gree
n
1
23
3a
4b
4 5
8
Fuse
YellowYellow
YellowYellow
Yel
low
Yel
low
RedRed
7
WhiteWhite
WhiteWhite4a
TanTan
TanTan
Yellow/BlackYellow/Black
LITE 2 LD-DIRECT IGNITION TROUBLESHOOTING w/Digital Ignition Control
8
MODEL MAXIMUM
125175250325400
3642423839
125175250325400
2836383838
MINIMUM
Temperature Rise
2733332830
2224242830
Lite, Lite 2, Series 1 & Series 2with 2” header connections
Series 1 with 1½” header connections
Btus
Resistanceat 20 K
or aboveDCV
2000K
200K
20K2K
hFE
2
20
200
1000200
750
PNPNPN
OFF
200m
DCA
20m
200m
10A
200
ACV
200μ
2000μ
Temp Resistance Temp Resistance
50° F 19.898 K Ohms 78° F 9.735 K Ohms
51° F 19.435 K Ohms 79° F 9.483 K Ohms
52° F 18.871 K Ohms 80° F 9.284 K Ohms
53° F 18.382 K Ohms 81° F 9.079 K Ohms
54° F 17.902 K Ohms 82° F 8.864 K Ohms
55° F 17.473 K Ohms 83° F 8.655 K Ohms
56° F 16.988 K Ohms 84° F 8.450 K Ohms
57° F 16.549 K Ohms 85° F 8.253 K Ohms
58° F 16.150 K Ohms 86° F 8.057 K Ohms
59° F 15.710 K Ohms 87° F 7.871 K Ohms
60° F 15.314 K Ohms 88° F 7.687 K Ohms
61° F 14.923 K Ohms 89° F 7.509 K Ohms
62° F 14.547 K Ohms 90° F 7.335 K Ohms
63° F 14.193 K Ohms 91° F 7.166 K Ohms
64° F 13.823 K Ohms 92° F 7.001 K Ohms
65° F 13.477 K Ohms 93° F 6.840 K Ohms
66° F 13.138 K Ohms 94° F 6.685 K Ohms
67° F 12.813 K Ohms 95° F 6.531 K Ohms
68° F 12.492 K Ohms 96° F 6.384 K Ohms
69° F 12.186 K Ohms 97° F 6.238 K Ohms
70° F 11.893 K Ohms 98° F 6.099 K Ohms
71° F 11.593 K Ohms 99° F 5.963 K Ohms
72° F 11.309 K Ohms 100° F 5.829 K Ohms
73° F 11.032 K Ohms 101° F 5.700 K Ohms
74° F 10.765 K Ohms 102° F 5.572 K Ohms
75° F 10.502 K Ohms 103° F 5.449 K Ohms
76° F 10.250 K Ohms 104° F 5.327 K Ohms
77° F 10.000 K Ohms
Safety Circuit TestLeave black probe on Transformerterminal with yellow wire.Move red probe to each component
Hot Surface Ignitor TestIgnitor must be disconnected fromthe Ignition Control and cool to the touch.Resistance through the Hot Surface Ignitorshould be 40 to 75 Ohms.
Temperature Rise Test Chart
Thermistor TestRemove thermistor leads from temperature board. Set meter totest resistance above 20 K Ohms. Using chart at the right,compare the actual water temperature to the resistance readingto determine if the thermistor is OK.
Thermistor Test Chart
240 VACTransformer
Yellow Wire
Fusible Link
DCV
2000K
200K
20K2K
hFE
2
20
2001000
200750
PNPNPN
OFF
200m
DCA
20m
200m
10A
200
ACV
200μ
2000μ
ACV above 30 V
Test Hot Surface Ignitor at Ambient Temperature- range 40 to 75 Ohms-
DCV
2000K
200K
20K2K
hFE
2
20
2001000
200750
PNPNPN
OFF
200m
DCA
20m
200m
10A
200
ACV
200μ
2000μ
Set meter to test resistance.
9
LITE 2 LJ TROUBLESHOOTING
24 VAC at far end of fuse?
Too much heat in control area.Look for down drafting, Roll-out,Soot,or Low Gas Pressure.Replace Fusible Link.
STEP 8 - Check Gas Valve
Does Ignitor heat up?
Replace PowerControl Board.
ReplaceIgnitor.
1) Check incoming power. (A & B)2) Turn off incoming power. Checkpositioning of Conversion Block.3) Replace Transformer.
1) Check for short circuits.2) Replace fuse.
STEP 4 - Check Fusible Link
Check wires for lose connections.Replace Ignition board.
24 VAC on white wireat Fusible Link? (4b)
STEP 1 - Check Transformer - Set meter to ACV above 240
Does heater fire? Replace GasValve.
Make certain all gas valvesare open, the correct fuelis provided to the heater, gaspressure and volume arecorrect.
STEP 3 - Check Fireman’s Switch Circuit
For the next tests insert and leave the common probein with the blue(2) wire.
24 VAC at 3a? Power Control is not sending power.Replace Power Control Board.
24 VAC at 3b?Fireman’s switch circuit is open.Make sure the external control iscalling for heat.
24 VAC on red wireat Fusible Link? (4a)
YES
NO
YES
NO
YES
NO
NO
NO
YES
YES
NO
YES
NO
YES
STEP 5 - Check High Limits One or both of the limits are open.(5b & 5c)1)Check for damage to bypass disc, heads,or exchanger.2)Jandy recommends replacing both limits.3)Do Temperature Rise Test.
STEP 6 - Check Pressure Switch
24 VAC at white wireof Pressure Switch? (5a)
YES
NO
24 VAC at black wireof Pressure Switch? (6)
Perform Back Pressure Test. If 2.5 PSI ormore, replace Pressure Switch. If less,check pump, filter, etc., for water flowproblems.YES
NO
STEP 7 - Check Hot Surface IgnitorNO Turn power off, disconnect Ignitor at 7a
and 7b. Perform Ignitor Test.Is resistance between 25 and 300 Ohms?
YES
Remove each fuse (7c & 7d).Check each for continuity.If either is blown, check for shortedwires, then replace fuse.If neither fuse is blown replace theignition control.
NO
After 10 seconds of Ignitorheat up, is there 24 VAC atbrown wire to gas valve?
NO
YES
For Thermostat troubleshooting refer to the installation manual.
YES
NO OK
For Ignitor Test, remove common probe from blue(2) wire.
For Gas Valve test reinsert the common probe in with the blue(2) wire.
1) Check incoming power. (A & B)2) Turn off incoming power. Checkpositioning of Conversion Block.3) Replace Transformer.
24 VAC betweenBlue 1 & Blue 2 wires?
YES
STEP 2 - Check Fuse (insert common probe in with blue 1 wire,touch other probe to far end of fuse)
12 VAC betweenBlue 2 & White 3 wires?
HOT SURFACE IGNITOR
INLET TEMPSENSORPOWER
ONFLAME
GAS
SAFETY
PUMP
BLOWER
FIREMANSWITCH
2 AM
P N
OR
MAL
EXT POWER
FUSIBLE LINKFUSIBLE LINK
135135ºº FFHIGH LIMITHIGH LIMIT
150150ºº FFHIGH LIMITHIGH LIMIT(RED DOT)(RED DOT)
PRESSUREPRESSURESWITCHSWITCH
BLACKBLACK
REDREDWHITEWHITE
WHITEWHITE
WHITEWHITE
FLAME SENSORFLAME SENSOR
HOT SURFACE IGNITORHOT SURFACE IGNITOR
MVMV
GASVALVE
THERMISTORTHERMISTOR
BLACKBLACK
115 or 230 VAC
YELLOWYELLOW
BROWNBROWN
FIREMAN’SFIREMAN’SSWITCHSWITCH
MODE
POOL-OFF-SPA UP DOWN PUMP
NORMAL
84 °F
POOL
REDRED
REDRED
FUSE
FUSEWHITESWHITES
WHITESWHITES
2 AMP, 2 AMP, 11¼”¼” LONG LONG FUSEFUSE
REDRED
REDRED
GREENGREEN
GREENGREEN
1
2
4a
A B
3a
4b
5a
5b
5c 6 3b
7a
7b
7c
7d
8
2 AMP, 2 AMP, 3/4” long3/4” long
1
23
POWER CONTROL BOARDPOWER CONTROL BOARD
TRAN
SFO
RM
ER
VO
LTA
GES
BE
TWEE
N B
LUE
(1) &
BLU
E(2)
–24
VAC
BE
TWEE
N B
LUE
(!) &
WH
ITE(
3) –
12 V
AC
- - -
10
MODEL MAXIMUM
125175250325400
3642423839
125175250325400
2836383838
MINIMUM
Temperature Rise
2733332830
2224242830
Lite, Lite 2, Series 1 & Series 2with 2” header connections
Series 1 with 1½” header connections
Btus
DCV
2000K
200K
20K2K
hFE
2
20
2001000
200750
PNPNPN
OFF
200m
DCA
20m
200m
10A
200
ACV
200μ
2000μ
Set meter to test resistance.
Temp Resistance Temp Resistance
50° F 19.898 K Ohms 78° F 9.735 K Ohms
51° F 19.435 K Ohms 79° F 9.483 K Ohms
52° F 18.871 K Ohms 80° F 9.284 K Ohms
53° F 18.382 K Ohms 81° F 9.079 K Ohms
54° F 17.902 K Ohms 82° F 8.864 K Ohms
55° F 17.473 K Ohms 83° F 8.655 K Ohms
56° F 16.988 K Ohms 84° F 8.450 K Ohms
57° F 16.549 K Ohms 85° F 8.253 K Ohms
58° F 16.150 K Ohms 86° F 8.057 K Ohms
59° F 15.710 K Ohms 87° F 7.871 K Ohms
60° F 15.314 K Ohms 88° F 7.687 K Ohms
61° F 14.923 K Ohms 89° F 7.509 K Ohms
62° F 14.547 K Ohms 90° F 7.335 K Ohms
63° F 14.193 K Ohms 91° F 7.166 K Ohms
64° F 13.823 K Ohms 92° F 7.001 K Ohms
65° F 13.477 K Ohms 93° F 6.840 K Ohms
66° F 13.138 K Ohms 94° F 6.685 K Ohms
67° F 12.813 K Ohms 95° F 6.531 K Ohms
68° F 12.492 K Ohms 96° F 6.384 K Ohms
69° F 12.186 K Ohms 97° F 6.238 K Ohms
70° F 11.893 K Ohms 98° F 6.099 K Ohms
71° F 11.593 K Ohms 99° F 5.963 K Ohms
72° F 11.309 K Ohms 100° F 5.829 K Ohms
73° F 11.032 K Ohms 101° F 5.700 K Ohms
74° F 10.765 K Ohms 102° F 5.572 K Ohms
75° F 10.502 K Ohms 103° F 5.449 K Ohms
76° F 10.250 K Ohms 104° F 5.327 K Ohms
77° F 10.000 K Ohms
Temperature Rise Test Chart
Thermistor TestRemove thermistor leads from ignition board. Set meter to testresistance above 20 K Ohms. Using chart at the right, comparethe actual water temperature to the resistance reading to determineif the thermistor is OK.
Thermistor Test Chart
HEATER SERVICE CODESFL0: Open switch in safety circuit.FL1: Temperature Sensor is open or shorted.FL2: Failed Ignition.FL3: Flame detected when no flame should exist.FL4: Hot Surface Ignitor problem.FL5: Brown-out condition exist.FL6: Signal to energize gas valve is not beingsent by controller.FL7: Fireman switch circuit is open.
Hot Surface Ignitor TestIgnitor must be disconnected from the Ignition Controland should be cool to the touch.Depending on the temperature of the ignitor, the resis-tance between the two leads of a good ignitor will be 25to 300 Ohms, typically 60 to 80 Ohms.
Resistance at 20 K
or aboveDCV
2000K
200K
20K2K
hFE
2
20
200
1000
200
750
PNPNPN
OFF
200m
DCA
20m
200m
10A
200
ACV
200μ
2000μ
11
Try to light the pilot.Does pilot light?
Does pilot stay onwhen gas valve
knob is released?
500+ mV @ PPand PP-TH
terminals? (1)
1. Verify gas is on.2. Check for air in gas line.3. Is pilot tube clogged?
If voltage is found at one and notthe other, replace Fuse Link.Check for Roll out, Soot, Downdrafting, Low Gas Pressure, etc.
No
1. Check P/G output .2. Check for shorted wires.3. Check broken wires.
1. Check for low Pilot Generatoroutput.
2. Check for partial shortsor loose wires.
3. Replace Pilot Generator.
500+ mV @and both terminals
of Fuse Link?
500+ mV @both terminals ofFireman’s Switch
Check that a control system(if installed) is calling for heator Fireman’s Switch is closed.
500+ mV @Black Wire of
Pressure Switch?
Perform Back Pressure Test. If2 PSI or more, replace switch.If less, check pump, filter, etc.for pressure problem.
500+ mV @White wire ofPressure Switch?
1. Check each High Limit individually. (3a & b)2. Check if damage to disc, heads, exchanger.3. Take Temperature Rise. (Water Flow?)
Set gas valve knob to pilot position.Set thermostat toggle to OFF.
Set rocker switch to ON
Is there 200+ mV@ Black wire ofPressure Switch?
Yes
Is there 200+ mV@ TH terminal ofthe Gas Valve?
NoIs there 500+ mV@ TH/PP onTemp. Board?
Yes
Move rocker switch to OFF.Rotate Gas Valve Knob toON. Move rocker switchto ON. Does heater fire?
Is there 500+ mV@ Valve (TH) onTemp. Board?
No
Yes
Yes
Is there 500+ mV@ TH terminal ofGas Valve?
Yes
ReplaceGas Valve
No
Yes
Yes
Yes
Yes
Yes
Yes
No
NoCheck and/or replaceblack wire from Valve(TH) terminal of Temp.Board and TH terminalof Gas Valve.
No
Perform Thermistor Test.
Replace Temp. Board
Disconnect Pot wires and jump potterminals. If voltage drops to 200+ mV,replace Temp. Control (P/N R0058200).
Check rockerswitch
Yes
No
Yes
No
No
No
No
No
No
1
2
3
4
5
5
6a6b
6a
7
LITE (LG - MILLIVOLT) TROUBLESHOOTING
Pilot
PPPP--THTH
THTH
PPPP
PRESSUREPRESSURESWITCHSWITCH
THERMISTORTHERMISTOR
PilotPilot
PILOTPILOTGENERATORGENERATOR
FUSIBLEFUSIBLELINKLINK
HIGH LIMITHIGH LIMIT150° F (RED DOT)150° F (RED DOT)
GAS VALVEGAS VALVE
TEMPERATURE CONTROLTEMPERATURE CONTROL
OrangeOrangeBlackBlackFIREMAN’SFIREMAN’S
SWITCH SWITCH BLOCKBLOCK
WhiteWhiteWhiteWhite
WhiteWhite
WhiteWhite
Red to PPRed to PP
WhiteWhite
Black t
o TH
Black t
o TH
BlackBlack
Yellow to
PP
Yellow to
PPAquaLink RS
SENSENPOTPOT
TH/PP+
(PP)Valve(TH)
White to PPWhite to PP--THTH
Note: Ten feet (10’) maximum Note: Ten feet (10’) maximum distance from heater to control.distance from heater to control.
HIGH LIMITHIGH LIMIT135° F135° F
3a, b
4 5
6a
7
2
1
3
6b
12
Black fromPressure Switch
Black to Gas Valve (TH)
Yellow to Gas Valve (PP)(This is the common wire to
provide power to the T-Stat Board)
Thermistor10 K Ohms
Orange
SENSENPOTPOT
TH/PP+
(PP)Valve(TH)
Black
Temperature Control
T-Stat Board
Temp Resistance Temp Resistance
50° F 19.898 K Ohms 78° F 9.735 K Ohms
51° F 19.435 K Ohms 79° F 9.483 K Ohms
52° F 18.871 K Ohms 80° F 9.284 K Ohms
53° F 18.382 K Ohms 81° F 9.079 K Ohms
54° F 17.902 K Ohms 82° F 8.864 K Ohms
55° F 17.473 K Ohms 83° F 8.655 K Ohms
56° F 16.988 K Ohms 84° F 8.450 K Ohms
57° F 16.549 K Ohms 85° F 8.253 K Ohms
58° F 16.150 K Ohms 86° F 8.057 K Ohms
59° F 15.710 K Ohms 87° F 7.871 K Ohms
60° F 15.314 K Ohms 88° F 7.687 K Ohms
61° F 14.923 K Ohms 89° F 7.509 K Ohms
62° F 14.547 K Ohms 90° F 7.335 K Ohms
63° F 14.193 K Ohms 91° F 7.166 K Ohms
64° F 13.823 K Ohms 92° F 7.001 K Ohms
65° F 13.477 K Ohms 93° F 6.840 K Ohms
66° F 13.138 K Ohms 94° F 6.685 K Ohms
67° F 12.813 K Ohms 95° F 6.531 K Ohms
68° F 12.492 K Ohms 96° F 6.384 K Ohms
69° F 12.186 K Ohms 97° F 6.238 K Ohms
70° F 11.893 K Ohms 98° F 6.099 K Ohms
71° F 11.593 K Ohms 99° F 5.963 K Ohms
72° F 11.309 K Ohms 100° F 5.829 K Ohms
73° F 11.032 K Ohms 101° F 5.700 K Ohms
74° F 10.765 K Ohms 102° F 5.572 K Ohms
75° F 10.502 K Ohms 103° F 5.449 K Ohms
76° F 10.250 K Ohms 104° F 5.327 K Ohms
77° F 10.000 K Ohms
Thermistor TestRemove thermistor leads from temperature board. Setmeter to test resistance above 20 K Ohms. Using chartbelow, compare the actual water temperature to theresistance reading.
No
Perform Thermistor Test, see below.
Replace Temp. Board
Disconnect Pot wires and jumppot terminals. If voltage drops to200+ mV, replace Temp. Control(P/N R0058200).
Is there 200+ mV @ Blackwire of Pressure Switch?
Yes
Is there 200+ mV @ THterminal of the Gas Valve?
No Is there 500+ mV @TH/PP on Temp. Board?
Check rocker switchNo
Yes
Move rocker switch to OFF.Rotate Gas Valve Knob toON. Move rocker switch toON. Does heater fire?
Is there 500+ mV @Valve (TH) on Temp. Board?
No
Yes
Yes
Is there 500+ mV @TH terminal of Gas Valve? No
Check and/or replace black wire fromValve (TH) terminal of Temp. Boardand TH terminal of Gas Valve.
Yes
Replace Gas Valve
No
Set Gas Valve Knob to PILOT position. Move heater rocker switchto ON. Set thermostat to maximum.
Temperature Control Testing
Total Millivolt Loss TestSet meter to 2 VDC. Place one probe on PP-TH and the otherprobe on TH. The meter will display the total millivolt loss throughthe safety loop.• Series One or older - 20 Millivolts loss or less.• Series 2 - 30 Millivolts loss or less.• Laars Lite LLG or LG - 80 Millivolts loss or less
Pilot
To Temperature Board
Fusible LinkWhite
PP-THTerminal
TH Terminal
Gas Valve
DCV
2000K200K
20K2K
hFE
2
20
2001000
200750
PNPNPN
OFF
200m
DCA
20m
200m10A
200
ACV
200μ
2000μ
2 VDC
13
LX OR LT TROUBLESHOOTING w/Digital Ignition Control
STEP 1 - Check Transformer24 VAC atred wire onTransformer?
NO
YES
For 24 VAC tests, common probe (black) can be left on yellow wire of transformer or any chassis ground.
12 VAC atwhite/yellow wireof Transformer?
Check incoming power. (115 / 230 VAC)Make certain correct conversion block is installed.Replace transformer.
Check incoming power. (115 / 230 VAC)Make certain correct conversion block isinstalled. Replace transformer.
NO
STEP 2 - Check Fuse24 VAC at red wire oftransformer terminal bar?
Check for short circuits in safetyloop. Replace fuse
YES
NO
STEP 3 - Check Safety LoopNote: If fan is on skip to Step 4 at top of page 2.
YES
24 VAC at first wire (black)of safety loop terminal bar?
Recheck transformer and fuseReplace thermostat.
YES
NO
24 VAC at second wire (white)of safety loop terminal bar?
24 VAC at white wire onPressure Switch?NO
YESNO
Water pressure related problem.Clean filter, baskets, etc..Do back pressure test.Replace Pressure Switch.
Is Fireman’ Switch Blockopen? Make certainexternal control systemis calling for heat.
YES
24 VAC at third wire (white)of safety loop terminal bar?
NO Thermostat is not calling forheat. Check thermistor,temperature setting. Replace thermostat.
24 VAC at fourth wire (white)of safety loop terminal bar?
NOHigh Limit Switch(es) openReplace both limits.Perform TemperatureRise Test.
YES
24 VAC at sixth wire(white) of safety loopterminal bar?
NO Fusible Link or Exhaust TempLimit open 24 VAC on both sidesof Fusible Link?
YES
24 VAC at fifth wire (white)of safety loop terminal bar?
NOYES
YESReset Exhaust TempLimit. Check for lockin flue and/or vent.
Replace Fusible Link.Check for down draft, soot,and/or low gas pressure.
NO
24 VAC at seventh wire (purple)of safety loop terminal bar?
YES
NO
YES
24 VAC at eighth wire (yellow/black)of safety loop terminal bar?
NO Air Pressure Switchopen. Is fan on?
NO YES
YES
24 VAC at yellow/blackwire of ignition controlterminal bar?
24 VAC atyellow/black wire ofAir Pressure Switch?
NO
ReplaceThermostat.
YES NO YES
24 VAC onyellow/blackat TH ofIgnition Control?
Check vacuumtube for kinksand or holes.Replace AirPressure Sw.NO
Check wireconnections
YES
Check wireconnections
YESNext Page
Check wire connections.Replace thermostat.
Check wire connections.Replace thermostat.
Is Fan on?NO
YES
Proceed tostep 5.
IGN/ 120 L1 L2
IND VAL GNDIGN/ 240 IGN/
FS
F2
F1
FC24V
FenwalIgnition Control
75
4a
TH
FanFan
Fireman’sSwitch
PressureSwitch
Hi Limit150° F
Hi Limit135° F
FuseLink
Exhaust LimitTemp Switch
Fan Pressure Switch
Hot Surface Igniter
Flame ProvingRod
Low Pressure Hi Lim Sw Ext Sw 1
Air Flo Sw
AGS
10 K Ohms Thermistor
Temp Sensor
MVMV
Low Pressure
C
Call for heat relay
YELLOW/BLACKYELLOW/BLACK
YELLOW/BLACKYELLOW/BLACK
GREENGREEN
YELLOWYELLOW
GREENGREEN
BROWNBROWNPURPLEPURPLE
REDRED
GR
AY
GR
AY
REDRED
BLACKBLACK
WHITEWHITE WHITEWHITE
WHITEWHITE
YELLOWYELLOW
BROWNBROWN
PURPLEPURPLE
Burner
BLACKBLACK
TransformerTransformerFuse
GroundGround
12 VAC12 VAC
24 VAC24 VAC
Thermostat(LX = GUI or LT = T-Stat)
IGNITION CONTROLTERMINAL BAR
#1959
SAFETY LOOPTERMINAL BAR
#1961
TRANSFORMERTERMINAL BAR
#1958
GAS VALVETERMINAL BAR
#1960
1
2
3
4
7a
WH/YELWH/YEL
REDRED
Gas ValveB
LA
CK
BLA
CK
6 WHITEWHITE
TANTANTANTAN
6aNO
Power Distr.Block
14
MODEL
LX or LT28
40
24
36
MINIMUM
TEMP. DIFF.
250
400
MAXIMUM
Is Fan on?
YES
NO
Replace Ignition Control
Remove connector at F1 & F2 4a of IgnitionControl. Perform continuity test between F1 & F2terminals of Ignition Control.Is there continuity?
NO
NO
YES
Check Fan wiring.Replace Fan.
STEP 4 - Check Fan
Remove connector atF1 & F2 of Ignition Control.Does Fan go off?
YESNO
Turn heater to off, wait atleast 45 seconds for post-purge to finish. Performcontinuity test between F1 &F2 terminals of the IgnitionControl. Is there continuity?
Replace IgnitionControl
Perform these stepsif fan never goes off.
Turn power off to heater,check for shorted wires,especially grey and blackwires at F1 & F2.
YES
Plug connector atF1 & F2 back in.
24 VAC at purple wire of theIgnition Control Terminal bar
NO
YES
Check wire connections.Replace thermostat.
24 VAC at purple wire interminal TH of the Ignition? 5
NO
Check wire and connections.
Is Hot Surface Ignitor glowing? 6NO
Turn power off. Disconnect Ignitorat 6a. Perform resistance test. Isresistance between 40 and 75Ohms?
YES
NO YES
Reconnect ignitor wires.Carefully check wiring. Turnpower on. If ignitor does notglow after pre-purge, replaceIgnition Control.
If resistance test shows Ignitor isopen, replace the Ignitor.If resistance test shows the Ignitor isshorted, locate and correct short,before replacing Ignitor. Note if theIgnitor is shorted it might damage theIgnition Control.
YES
YES
After 35 seconds of ignitor heatup, is there 24 VAC at VALterminal of the Ignition Control? Replace Ignition Control.
NO
24 VAC at brown wire inIgnition Control Terminal bar?
YES
NO
Check wire and connections.
24 VAC at brown wire in GasValve Terminal bar?
YES
NO
Replace Thermostat.
24 VAC at brown wire at Gas Valve? 7a Check wire and connections.NO
YES
STEP 6- Check Ignitor
STEP 5 - Start Ignition Sequence
STEP 7- Check Gas Valve
Does the heater fire?NO
Make certain all gas valves are open. The correct fuel is providedto the heater, gas pressure and volume are correct.
Replace the Gas ValveOK
SERVICE CODESLOW PRESSURE - Water pressure relatedproblem or blown fuse. Clean filter and allbaskets. Do a back pressure test.Check Fuse. If the fuse is blown, check forshort circuits in the control wiring.HI LIM SW. Low water flow problem. Highlimit(s) open.Replace limit(s), do a Temperature Rise Test.EXT. SW. 1 - Fusible Link or Exhaust Temp.Limit Switch open. Too much heat in thecabinet (Fusible Link) or flue (Exhaust Temp.Limit Switch).Fusible Link open; check for sooted heatexchanger, low gas pressure, down draftcondition and or water flow problem. Do aGas Pressure Test and Temperature Rise Test.Exhaust Temp Limit Switch check forblockage of vent.AIR FLOW SW - Insufficient vacuum toclose the air pressure switch. Make certain thefan is running. Check the air hose from the fanto the Air Pressure Switch for holes and kinks.If the fan never switches to high speed replacethe Ignition Control.AGS - Automatic Gas Shutdown simplymeans the Ignition Control did not senseflame rectification. Make certain all gas cocksare open, and there is sufficient gas pressureand volume (gas line sized properly). If theheater fires and then the flame goes outquickly, it indicates the rectification signal isnot returning to the Ignition Control. Checkfor poor or missing ground wire.Temp Sensor - Water temperature sensoropen or shorted. The sensor is a 10 K Ohmsthermistor. A sensor failure may indicate poorwater chemistry. Carefully test the water,concentrating on Total Alkalinity and pH.
TEMPERATURE RISE
15
LX OR LT low NOX TROUBLESHOOTING
STEP 1 - Check Transformer
24 VAC atred wire onTransformer?
NO
YES
For 24 VAC tests, common probe (black) can be left on yellow wire of transformer or any chassis ground.
12 VAC atwhite/yellow wireof Transformer?
Check incoming power. (115 / 230 VAC)Make certain correct conversion block isinstalled. Replace transformer.
Check incoming power. (115 / 230 VAC)Make certain correct conversion block isinstalled. Replace transformer.
NO
STEP 2 - Check Fuse24 VAC at red wire oftransformer terminal bar?
Check for short circuits insafety loop. Replace fuse
YES
NO
STEP 3 - Check Safety LoopNote: If fan is on skip to Step 4 at top of page 2.
YES
24 VAC at first wire (black)of safety loop terminal bar?
Recheck transformer and fuseReplace thermostat.
YES
NO
24 VAC at second wire (white)of safety loop terminal bar?
24 VAC at white wire onPressure Switch?
NO
YESNO
Water pressure related problem.Clean filter, baskets, etc..Do back pressure test.Replace Pressure Switch.
Fireman’ SwitchBlock open. Makecertain externalcontrol system iscalling for heat.
YES
24 VAC at third wire (white)of safety loop terminal bar?
NO Thermostat is not calling for heat.Check thermistor, temperaturesetting. Replace thermostat.
24 VAC at fourth wire (white)of safety loop terminal bar?
NO High Limit Switch(es) openReplace both limits. PerformTemperature Rise Test.
YES
24 VAC at sixth wire(white) of safety loopterminal bar?
NO Fusible Link or Exhaust Temp Limitopen24 VAC on both sides ofFusible Link?
YES
24 VAC at fifth wire (white)of safety loop terminal bar?
NO
YES
YES
Reset Exhaust TempLimit.Check for blockin flue and/or vent.
Replace Fusible Link.Check for down draft, soot,and/or low gas pressure.
NO
24 VAC at seventh wire (purple)of safety loop terminal bar?
YES
NO
YES
24 VAC at eighth wire (yellow/black)of safety loop terminal bar?
NO Air Pressure Switchopen. Is fan on?
NO YES
YES
24 VAC at yellow/black wire ofignition control terminal bar?
24 VAC atyellow/black wire ofAir Pressure Switch?NO
ReplaceThermostat.
YESNO YES
24 VAC onyellow/blackat TH ofIgnition Control?
Check vacuumtube for kinks andor holes.Replace AirPressure Switch.
NO
Check wire connections
YES
Check wireconnections
YES NextPage
Check wire connections.Replace thermostat.
Check wire connections.Replace thermostat.
Fireman’sSwitch
Water PressureSwitch
Hi Limit150° F
Hi Limit135° F
FusibleLink
Exhaust LimitTemp Switch
Air Pressure Switch
TransformerTransformer
Hot Surface Igniter
Flame ProvingRod
Fuse
Low Pressure Hi Lim Sw Ext Sw 1
Air Flo Sw
AGS
10 K Ohms Thermistor
Temp Sensor
MVMV
GroundGround
Low PressureThermostat
(LX = GUI or LT = T-Stat)
IGN
240
L1 TH VAL
GND
FS
F2F1
24 V
AC
C
NO
12 VAC12 VAC
24 VAC24 VAC
Call for heat relay
FCIG
N 12
0
PS
Burner
Gas Valve
FanFan
1Power Distr.Block
115/230Power
2
IGNITION CONTROLTERMINAL BAR
SAFETY LOOPTERMINAL BAR
TRANSFORMERTERMINAL BAR
3
4
6a
GAS VALVETERMINAL BAR
6
75
4a
7a
GREENGREENBROWNBROWN
PURPLEPURPLE
BLACK
YELLOW/BLACKYELLOW/BLACK
REDRED
GREENGREEN
YELLOWYELLOWWH/YELWH/YEL
REDRED
YELLOW/BLACKYELLOW/BLACK
BLACKBLACK
WHITEWHITE
WHITEWHITE
WHITEWHITE
YELLOWYELLOW
BROWNBROWN
BLACKBLACKWHITEWHITE
PURPLEPURPLE
GR
AY
GR
AY
BL
AC
KB
LA
CK
16
MODEL
LX or LT 2840
2436
MINIMUM
TEMP. DIFF.
250400
MAXIMUM
Is Fan on?
YES
NO
Replace Ignition Control
Remove connector at F1 & F2 4a of IgnitionControl. Perform continuity test between F1 & F2terminals of Ignition Control.Is there continuity?
NO
NO
YES
Check Fan wiring.Replace Fan.
STEP 4 - Check Fan
Remove connector atF1 & F2 of Ignition Control.Does Fan go off?
YESNO
Turn heater to off, wait atleast 45 seconds for post-purge to finish. Performcontinuity test between F1 &F2 terminals of the IgnitionControl. Is there continuity?
Replace IgnitionControl
Perform thesesteps if fannever goes off.
Turn power off to heater,check for shorted wires,especially grey and blackwires at F1 & F2.
YES
Plug connector atF1 & F2 back in.
24 VAC at purple wire of theIgnition Control Terminal bar
NO
YES
Check wire connections.Replace thermostat.
24 VAC at purple wire interminal PS of the Ignition? 5
NOCheck wire and connections.
Is Hot Surface Ignitor glowing? 6NO
Turn power off. DisconnectIgnitor at 6a. Perform resistancetest. Is resistance between 40and 75 Ohms?
YES
NO YES
Reconnect ignitor wires.Carefully check wiring.Turn power on. If ignitordoes not glow after pre-purge, replace IgnitionControl.
If resistance test shows Ignitor isopen, replace the Ignitor.If resistance test shows the Ignitor isshorted, locate and correct short,before replacing Ignitor. Note if theIgnitor is shorted it might damage theIgnition Control.
YES
YES
After 35 seconds of Ignitor heatup, is there 24 VAC at VALterminal of the Ignition Control? Replace Ignition Control.
NO
24 VAC at brown wire inIgnition Control Terminal bar?
YES
NO
Check wire and connections.
24 VAC at brown wire in GasValve Terminal bar?
YES
NO
Replace Thermostat.
24 VAC at brown wire at Gas Valve? 7a Check wire and connections.NO
YES
STEP 6- Check Ignitor
STEP 5 - Start Ignition Sequence
STEP 7- Check Gas Valve
Does the heater fire?NO Make certain all gas valves are open. The correct fuel is provided
to the heater, gas pressure and volume are correct.Replace the Gas Valve
OK
SERVICE CODESLOW PRESSURE - Water pressure relatedproblem or blown fuse. Clean filter and all baskets.Do a back pressure test.Check Fuse. If the fuse is blown, check for shortcircuits in the control wiring.HI LIM SW. Low water flow problem. Highlimit(s) open.Replace limit(s), do a Temperature Rise Test.EXT. SW. 1 - Fusible Link or Exhaust Temp. LimitSwitch open. Too much heat in the cabinet (FusibleLink) or flue (Exhaust Temp. Limit Switch).Fusible Link open; check for sooted heat ex-changer, low gas pressure, down draft conditionand or water flow problem. Do a Gas Pressure Testand Temperature Rise Test.Exhaust Temp Limit Switch check for blockage ofvent.AIR FLOW SW - Insufficient vacuum to close theair pressure switch. Make certain the fan isrunning. Check the air hose from the fan to the AirPressure Switch for holes and kinks. If the fannever switches to high speed replace the IgnitionControl.AGS - Automatic Gas Shutdown simply means theIgnition Control did not sense flame rectification.Make certain all gas cocks are open, and there issufficient gas pressure and volume (gas line sizedproperly). If the heater fires and then the flamegoes out quickly, it indicates the rectification signalis not returning to the Ignition Control. Check forpoor or missing ground wire.Temp Sensor - Water temperature sensor open orshorted. The sensor is a 10 K Ohms thermistor. Asensor failure may indicate poor water chemistry.Carefully test the water, concentrating on TotalAlkalinity and pH.
Has fan speed slowed?NO
Replace Ignition Control.YES
TEMPERATURE RISE
17
STEP 124 VAC
at Transformer?
No 1. Check incoming power2. Check Transformer wiring.3. Replace Transformer.
STEP 2 24 VAC at Red wire of
terminal block?
No Fuse is blown. Look for short circuits. Do not jumper or bypass fuse. Replace fuse with same size & amperage.
Yes
STEP 3 24 VAC at
White wire of terminal block?
No Check Fireman’s switch. If a remote is installed make sureit is calling for heat.
Yes
STEP 4 24 VAC at
White wire of Pressure Switch?
No
Yes
1. Check each Limit individually.
2. Check if damage to disc, head, exchanger.3. Perform Temperature Rise Test.
4a & 4b
STEP 524 VAC at
Black wire of Pressure Switch?
No
Yes
Is Pump On? Perform Back Pressure test.If 2 PSI or more replace pressure switch.If less, check pump, filter, plumbing andheat exchanger for water flow restrictions.
STEP 624 VAC at
Black/Yellow wireof Ignition Control?
No
Yes
Is Temp Board calling for heat?
Do Thermistor Test.
Yes Good Replace Temp Board.
Replace Thermistor. Failed
STEP 7Is Fan On?
NoIs there 120 VAC at F2?
STEP 8
Yes No
Check supply wire.
Yes
Is there 120 VAC at F1?
Yes
No Yes
Make sure there is24 VAC at IND, if there is, replace Ignition Control.
Check wiring to Fan.If wiring is OK, replace Fan.
24 VAC at TH of Ignition Control?
No
Yes
1. Check for vent blockage or dirty air filter.2. Perform Air Flow Test.3. Replace Venturi Pressure Switch.
STEP 9
Is Ignitor glowingNo
Yes
Check Ignitor and supply wiring.Perform Ignitor Resistance Test.Replace Ignitor.
24 VAC at Brown wire
of Gas Valve?
Check Burner and Vent Limits.
10a & 10b
9
8
Yes
Does heater fire?Is Gas Valve On?Do a supply side gas pressure test.Replace Gas valve.
STEP 10
Yes
Yes, but goes out after a few seconds.Heater is not sensing rectification.Check commons, make surecombustion chamber is grounded.If all is OK replace Ignition Control.
No
No
Go to Step 7
HiE2 TROUBLESHOOTING w/ Digital Ignition Control
WhiteWhite
RedRed
RedRed
BlackBlack
WhiteWhite
GAS VALVE
BURNER LIMIT
VENT LIMIT
FAN OR COMBUSTION BLOWER
YellowYellow
WhiteWhite
TEMPERATURE CONTROL
HIGH LIMIT150° F
HIGH LIMIT135° F
PRESSURE SWITCH
120 VACONLY
THERMISTOR
Whi
teW
hite
Bla
ckB
lack
Whi
teW
hite
RedRed
Black/YellowBlack/Yellow
VENTURI or DIFFERENTIAL PRESSURE SWITCH
HOT SURFACE IGNITOR
FIREMAN’SSWITCH
CONNECTION
BrownBrown
BlackBlack
PurplePurple
WhiteWhite
BrownBrown
1
TRANSFORMER
23
4a
4b
4 5
6b
6
10
10a10b
6a
9
BURNER
FUSE
Black/YellowBlack/Yellow
IGN 240
L1L2IGN/FSTHIND
GND
F1F2
FC24V
FENWAL DIGITALIGNITION CONTROL
7
8
IGN 120
VAL
Bla
ckB
lack
Gra
yG
ray
18
MODEL
EHE(HI E2) 2920
MINIMUM
TEMP. DIFF.
350
MAXIMUM
Temp Resistance Temp Resistance
50° F 19.898 K Ohms 78° F 9.735 K Ohms
51° F 19.435 K Ohms 79° F 9.483 K Ohms
52° F 18.871 K Ohms 80° F 9.284 K Ohms
53° F 18.382 K Ohms 81° F 9.079 K Ohms
54° F 17.902 K Ohms 82° F 8.864 K Ohms
55° F 17.473 K Ohms 83° F 8.655 K Ohms
56° F 16.988 K Ohms 84° F 8.450 K Ohms
57° F 16.549 K Ohms 85° F 8.253 K Ohms
58° F 16.150 K Ohms 86° F 8.057 K Ohms
59° F 15.710 K Ohms 87° F 7.871 K Ohms
60° F 15.314 K Ohms 88° F 7.687 K Ohms
61° F 14.923 K Ohms 89° F 7.509 K Ohms
62° F 14.547 K Ohms 90° F 7.335 K Ohms
63° F 14.193 K Ohms 91° F 7.166 K Ohms
64° F 13.823 K Ohms 92° F 7.001 K Ohms
65° F 13.477 K Ohms 93° F 6.840 K Ohms
66° F 13.138 K Ohms 94° F 6.685 K Ohms
67° F 12.813 K Ohms 95° F 6.531 K Ohms
68° F 12.492 K Ohms 96° F 6.384 K Ohms
69° F 12.186 K Ohms 97° F 6.238 K Ohms
70° F 11.893 K Ohms 98° F 6.099 K Ohms
71° F 11.593 K Ohms 99° F 5.963 K Ohms
72° F 11.309 K Ohms 100° F 5.829 K Ohms
73° F 11.032 K Ohms 101° F 5.700 K Ohms
74° F 10.765 K Ohms 102° F 5.572 K Ohms
75° F 10.502 K Ohms 103° F 5.449 K Ohms
76° F 10.250 K Ohms 104° F 5.327 K Ohms
77° F 10.000 K Ohms
Safety Circuit TestLeave black probe on Transformerterminal with yellow wire.Move red probe to each component
Hot Surface Ignitor TestIgnitor must be disconnected fromthe Ignition Control and cool to the touch.Resistance through the Hot Surface Ignitorshould be 40 to 75 Ohms.
Thermistor TestRemove thermistor leads from temperature board. Set meter totest resistance above 20 K Ohms. Using chart at the right,compare the actual water temperature to the resistance readingto determine if the thermistor is OK.
Thermistor Test Chart
DCV
2000K
200K
20K2K
hFE
2
20
2001000
200750
PNPNPN
OFF
200m
DCA
20m
200m
10A
200
ACV
200µ
2000µ
Test Hot Surface Ignitor at Ambient Temperature- range 40 to 75 Ohms-
120 VACTransformer
Yellow Wire
Fireman’s Switch block
ACV above 30 V
DCV
2000K
200K
20K2K
hFE
2
20
200
1000200
750
PNPNPN
OFF
200m
DCA
20m
200m
10A
200
ACV
200µ
2000µ
DCV
2000K
200K
20K2K
hFE
2
20
200
1000200
750
PNPNPN
OFF
200m
DCA
20m
200m
10A
200
ACV
200µ
2000µ
Temperature Rise Test
19
���������� ���������
������������
������ ���
���������
���������������� ����������
��������
������������������� �
���������
��������
������������������� �
��������������
���������
�������������������
��������������
���
���������
�� ������� ����������� ������������ ����������� ��
���������� ���� ��� ��� �� � ��� ��� �� � ����� � �� ����� �������������� ���������� ��
� �������������� � ������� ��� �� �������!� �� ��!�� �!� ������������!�����������������
�� ������������������������������� �� �� �� �� �� ���� ������� ��������� �����!������!��"�������� �������������������
�� ��� ��������������������� ��������� �� �!����������������� �������!�����������!������!�����
�"������ ����������� �� ��� ���������
���������������
��#���� ����� ������� � ��
���
����� ������������������������
������������ ��
���
���������������
� ������ �����������
���
��������������
�� ������������ ������������ �� � �
�
�
�
�
�
��������� ��������������� ������
� �������� ��������������� ������� ��#���� ������
�������������
������������ ��
������������������ ���� ������������������������������
� ������������������ �� � �
���������� �������� ������������
��������� ����������������
�����
������������������������
� � �
��
�
�
�
�
�
�� �
�
�
�
�
�
��
�
��
�
���������������������� ������ ��� ���������� ���
20
��������������� ���������� � �
������� ������������ ������
����������������
������������
���
������������� ���� ���������� ��������������
���
����������� ��������� �
���
�������������� ��� �����
� ������� ��
���
������������ ��� �
���������������������������
���
������������ �������������������������������
���
������������ ��� ����������� �
������ ��
���
���������������
���
����������������������
������������ �
���
���������������
� ����� �
��
��
��
��
��
���������������������������������� ������ ����������� ����� �����!��� �������� ���������� ������� ����������������� ������ ��������������
���������������
��
��
��
��
��
�
�
�
�
�
"# ��������������� ��# ��������������� ������ ��$# ������������������
"# ������������ �����������# ������������������������ ����������$# ���������� �� ����������%����&������#'# ��������������
"# ������������������� ������������# ������������������������������������
��������������� ����� ��� �� ��������� ������������� ������������������ ����� � ��� ����� � �� ������������� ����� ��!��� ����
"# ����������������� ����������# ��������������� �������$# ������������������� ���'# �������������������
� ��
"# �������������������������# ������������������������������$# �����������������������
�� �� ��
�������������������� ������������� ������
Pressure SwitchR0013200
ThermostatR0318800
Gas ValveNatural - R0096400Propane - R0096900
On/Off SwitchE0146600
GeneratorW0036901
Rear Header RedundantHigh Limit(275� F)R0012800
Fusible LinkR0012200
Fireman’s Switch BlockR0097800
High Limit(135� F) R0023000
High Limit(150� F) R0022700
White
Red
321
TP (2)
TH/TP (1)
TH (3)O
N
OFF
PIL
OT
White
White White
White
Black
Black
Black
Yellow
Yellow
4A
4C4B
3
1
6
6A
6B
54
2
���������� �����������
��
21
PressureSwitch
Thermistor
Pilot
PilotGenerator
FusibleLink
Hi-Limit135° F Hi-Limit
(150° F)
Gas Valve
Temperature Control
Orange
Red
SENSENPOTPOT
TH/PP+
(PP)Valve(TH)
Red
Red
White
Black
TP/TH
TH
TP 1
2
Black
Black
3a3b
4a
5aBlack
to TH
Yellow to
TP
White to TP/TH
Red to TP
Laars
5b
Piezo Ignitor
Black
Pilot Coil
4b
��������������� ��������� ��������
����� ������������������������
����������������
������������������ �!
����������"#$
#� ���%����������&� '��(��%���������������)� *�� �����+���(�����
*%����������%�+��������������������������,��� ��(��-+���.����'��(�%��������������������� ������������������������������
/�
#� '��(���01��+� +��"#$��&� '��(��%����������������)� '��(�� ����(���
#� '��(��%������������1���������+� +��
&� '��(��%��� ��������������������������
)� 2� ��(�������1���������
���������������������������%�-+���.����"&$
����������2��3����%������+��4��(���������(�������(���"5�$
���%����6�(�������+���������*%&����4*��������,��� ��(�����(��*%�����,�(��(�� +� ,�%����,���(�%��� ����+��� �������
����������2�������%�%����! .�����������+���4��(��"5�$
#��'��(����(��!��.������+�������")�7�$
&� '��(��%����������� �������������8(������
������������� ��� ��� ��� ���� ������� ������������� �����
����� ������������� ���
*��������&��������2��������%�����+���4��(���"5�$
9��
*��������&���������!����������%����1���������
/�*������������������!0�������� ��6�����
9��
:������(�������(����;--��2������1��������<�������;/�:������(�������(����;/��������������%���
*�����������������������"�!$������ ��6�����
/�
9��
9��
*������������������!����������%1���������
9��
2� ��(�1��������
/�
9��
9��
9��
9��
9��
/�
/�
'��(�����0����� ��(����(������%���������"�!$���������%���� ��6���������!����������%�1���������
/�
���%������������������,�����������
2� ��(����� ��6����
'��(����(������(�
9��
/�
9��
/�
/�
/�
/�
/�
��(����(���������������=+� � ������������*%����������� �����&������,�� ��(����� ��'�������"�0/2���>&��$�
���������� ���������
��������������� �������������������
22
Black fromPressure Switch
Black to Gas Valve (TH)
Yellow to Gas Valve (PP)
Thermistor10 K Ohms
Orange
SENSENPOTPOT
TH/PP+
(PP)Valve(TH)
Black
Laars
Temperature Control
T-Stat Board
Ω at 20 K
COMmA Ωv10A
10.00
V ---
∼V
Ω
Waterpik TechnologiesLaars & Jandy Products
2M
200K
20K
2K
200
200m2m
2
20
2001000 200750
ONOF F
PNP
NPN
A ---77º F.
���������������������� �
���� �������� ���� ��������
��° - #?�>?>�<�;��� @>° - ?�@)��<�;���
�#° - #?�5)��<�;��� @?° - ?�5>)�<�;���
�&° - #>�>@#�<�;��� >�° - ?�&>5�<�;���
�)° - #>�)>&�<�;��� >#° - ?��@?�<�;���
�5° - #@�?�&�<�;��� >&° - >�>A5�<�;���
��° - #@�5@)�<�;��� >)° - >�A���<�;���
�A° - #A�?>>�<�;��� >5° - >�5���<�;���
�@° - #A��5?�<�;��� >�° - >�&�)�<�;���
�>° - #A�#���<�;��� >A° - >���@�<�;���
�?° - #��@#��<�;��� >@° - @�>@#�<�;���
A�° - #��)#5�<�;��� >>° - @�A>@�<�;���
A#° - #5�?&)�<�;��� >?° - @���?�<�;���
A&° - #5��5@�<�;��� ?�° - @�))��<�;���
A)° - #5�#?)�<�;��� ?#° - @�#AA�<�;���
A5° - #)�>&)�<�;��� ?&° - @���#�<�;���
A�° - #)�5@@�<�;��� ?)° - A�>5��<�;���
AA° - #)�#)>�<�;��� ?5° - A�A>��<�;���
A@° - #&�>#)�<�;��� ?�° - A��)#�<�;���
A>° - #&�5?&�<�;��� ?A° - A�)>5�<�;���
A?° - #&�#>A�<�;��� ?@° - A�&)>�<�;���
@�° - ##�>?)�<�;��� ?>° - A��??�<�;���
@#° - ##��?)�<�;��� ??° - ��?A)�<�;���
@&° - ##�)�?�<�;��� #��° - ��>&?�<�;���
@)° - ##��)&�<�;��� #�#° - ��@���<�;���
@5° - #��@A��<�;��� #�&° - ���@&�<�;���
@�° - #����&�<�;��� #�)° - ��55?�<�;���
@A° - #��&���<�;��� #�5° - ��)&@�<�;���
@@° - #������<�;���
�������� �����������������������
�������������������������� ������� ����������������������� ������������������� � �������������� ������������������� �������� �������������� !"#� ������$�%�&�������������������'�����'������������� �����(� ����������������������
������������� ������������������ ����������������������������� �������������������������
*��������&��������2��������%�����+���4��(���"5�$
9��
*��������&���������!����������%����1���������
/�*������������������!0�������� ��6�����
9��
:������(�������(����;--��2������1��������<�������;/�:������(�������(����;/�������������%���
*�����������������������"�!$������ ��6�����
/�
9��
9��
*������������������!����������%1���������
9��
2� ��(�1��������
/�
/�
/�
'��(�����0����� ��(����(������%���������"�!$���������%���� ��6���������!����������%�1���������
���%�������������������,�����������
2� ��(����� ��6����
'��(����(������(�
/� ��(����(���������������=+� � ������������*%����������� �����&������,�� ��(����� ��'�������"�0/2���>&��$�
��������������� �������������������
���������� ��������� 23
D C
TTFF
ThermostatE971
115 VACNeutral
ON-OFF SwitchE782
E786
Twist Lock PlugE784
Hi LimitE771
E
F
Pressure Switch
104089-02
G
White
Black
Black
Black
Orange
Yellow Yellow
Primary ControlN060
TransformerN023
White Oil Pump
B A
Hi LimitE722
Black
White
Black
MotorN010
Ground
Current Flow
Wire Nut
Neu
tral
Cadmium CellN061
������������ ����������� �� ���������
Check voltage at ACheck voltage at A No
Yes
Check voltage at BCheck voltage at B
Check circuit breakerCheck circuit breaker
No Bad ON/OFF Switch (E782)Bad ON/OFF Switch (E782)
Yes
Check voltage at CCheck voltage at C•Loose Twist Lock Plug•Short in Wire Harness (R575)•Bad Twist Lock Plug
•Loose Twist Lock Plug•Short in Wire Harness (R575)•Bad Twist Lock Plug
No
Yes
Check voltage at DCheck voltage at D No Bad Hi Limit (E771)Bad Hi Limit (E771)
No
Yes
Check voltage at ECheck voltage at E•Loose Twist Lock Plug•Short in Wire Harness (R575)•Bad Twist Lock Plug
•Loose Twist Lock Plug•Short in Wire Harness (R575)•Bad Twist Lock Plug
Check voltage at FCheck voltage at F
Yes
No•Water flow problem •Bad Pressure Switch •Misadjusted Pressure Switch•Blocked Siphon Loop Connection
•Water flow problem •Bad Pressure Switch •Misadjusted Pressure Switch•Blocked Siphon Loop Connection
Check voltage at GCheck voltage at G
Yes
No Bad wire in Armored Cable (BX)Bad wire in Armored Cable (BX)
Heater Doesn’t FireHeater Doesn’t Fire
Yes
Press RESET button on Primary Control Once 1) If unit fire and stays on, unit lost prime to Oil Pump2) If unit fires and goes out, or doesn’tstay lit, or goes into RESET after 45 seconds …. this is a Oil Burner or combustion problem CALL QUALIFIED OIL SERVICE
Press RESET button on Primary Control Once 1) If unit fire and stays on, unit lost prime to Oil Pump2) If unit fires and goes out, or doesn’tstay lit, or goes into RESET after 45 seconds …. this is a Oil Burner or combustion problem CALL QUALIFIED OIL SERVICE
If you press RESET on Primary Control, and RESET button on Oil Burner Motor, and nothing happens
1) Turn off power to heater, then temporarily place a jumper from T to T on the Primary Control and turn power on. If unit fires, either the Thermostat (E971) or the High Limit (E722), or the Fireman’s Switch has a problem.2) If unit doesn’t fire, remove one of the yellow wires from either terminalmarked F on the Primary Control. If unit fires now, either:
Bad Cadmium Cell (N061)Bad Primary Control, orthere is a fire in the combustion chamber…. CALLOIL SERVICE
If you press RESET on Primary Control, and RESET button on Oil Burner Motor, and nothing happens
1) Turn off power to heater, then temporarily place a jumper from T to T on the Primary Control and turn power on. If unit fires, either the Thermostat (E971) or the High Limit (E722), or the Fireman’s Switch has a problem.2) If unit doesn’t fire, remove one of the yellow wires from either terminalmarked F on the Primary Control. If unit fires now, either:
Bad Cadmium Cell (N061)Bad Primary Control, orthere is a fire in the combustion chamber…. CALLOIL SERVICE
Caution; Possible Electrocution: This circuit is high voltage, take extremely care when checking.