15
-1- 5% 1 the First Overtone of DF Broadened by HF 5 U.G. "Desai, N.M. Gailar and R.J. Love11 Department of Physics and Astronomy The University of Tennessee, Knoxville, Tennessee, 37916 ABSTRACT The self-shifts of the lines in the fundamental of HI? from P(7) to R(8) and the line shifts in the first overtone band of DF when perturbed by HF were measured from P(7) to R(6), Pressure-induced shifts in the HF fundamental were studied at room temperature and at pressures of HF varying from 37.5 cm of Hg to 113.5 cm of Hg. by Herget, but the estimated error 0.5 x 10 The shifts agreed with those observed -4 cm-'/cm Hg for the present study was about one-third of that of Herget. ranged from 5.48 cm of Hg to 22 cm of Hg, and total pressure of mixed The partial pressures of DF gabes ranged from 36.12 cm of Hg to 121.8 cm of Hg. ference and sample cells were llO°C, 12OoC, 15OoC, and 134 C. Temperatures of re- 0 The shifts oscillate with a period of one in J and with increasing amplitude in the wings from R(1) to R(6) and P(3) to P(7). The direction of the shifts is tha same as that found for the DC1-HC1 system and is opposite to that pre- dicted by the simple near-resonant dipole theory. The magnitude of the shifts in the present study are considerably larger than those found from the DC1-HC1 study. Index Headings: Absorption; Atmospheric optics; Infrared; Spectra. https://ntrs.nasa.gov/search.jsp?R=19710023696 2018-06-18T17:14:32+00:00Z

search.jsp?R=19710023696 2018-03 … · The cell-manifold pressure was then read on a Bourdon gauge. ... consider the sources of error in the experiment to ... all the possible precautions

  • Upload
    lecong

  • View
    218

  • Download
    4

Embed Size (px)

Citation preview

Page 1: search.jsp?R=19710023696 2018-03 … · The cell-manifold pressure was then read on a Bourdon gauge. ... consider the sources of error in the experiment to ... all the possible precautions

-1-

5% 1 the First Overtone of DF Broadened by HF 5

U.G. "Desai, N.M. Gailar and R.J. Love11

Department of Physics and Astronomy The University of Tennessee, Knoxville, Tennessee, 37916

ABSTRACT

The self-shifts of the lines in the fundamental of HI? from P(7) to

R(8) and the line shifts in the first overtone band of DF when perturbed

by HF were measured from P(7) to R(6), Pressure-induced shifts in the HF

fundamental were studied at room temperature and at pressures of HF varying

from 37.5 cm of Hg to 113.5 cm of H g .

by Herget, but the estimated error 0.5 x 10

The shifts agreed with those observed -4

cm-'/cm Hg for the present

study was about one-third of that of Herget.

ranged from 5.48 cm of Hg to 22 cm of Hg, and total pressure of mixed

The partial pressures of DF

gabes ranged from 36.12 cm of Hg to 121.8 cm of Hg.

ference and sample cells were llO°C, 12OoC, 15OoC, and 134 C.

Temperatures of re- 0 The shifts

oscillate with a period of one in J and with increasing amplitude in the

wings from R(1) to R(6) and P(3) to P(7). The direction of the shifts is

tha same as that found for the DC1-HC1 system and is opposite to that pre-

dicted by the simple near-resonant dipole theory. The magnitude of the

shifts in the present study are considerably larger than those found from

the DC1-HC1 study.

Index Headings: Absorption; Atmospheric optics; Infrared; Spectra.

https://ntrs.nasa.gov/search.jsp?R=19710023696 2018-06-18T17:14:32+00:00Z

Page 2: search.jsp?R=19710023696 2018-03 … · The cell-manifold pressure was then read on a Bourdon gauge. ... consider the sources of error in the experiment to ... all the possible precautions

-2-

One o’f the most interesting studies of line shifting reported in the 2 recent literature is that of Jaffe, et al., who reported cy the pressure-

induced shifts of DC1 due to HC1 and also on the shifts of HC1 due to DC1.

They observed in the first overtone band of DC1 broadened by HC1 not only

the expected J-dependence of the line shifts, but also a striking oscil-

lation from line to line of the magnitude of the shift.

phenomenon is due to near-resonant dipolar interaction between DC1 and HC1.

In HC1-DC1 they found no oscillations in the shifts. Another example of

oscillating line shifts has been discovered in HF broadened by HC1.

They suggest this

3

The authors decided to study DF-KF, to see if the large oscillations

would occur that were found in DC1-HC1 and, if so, if the simple theory

of near-resonant dipolar interaction would correctly predict the directions

of the oscillations.

do occur, are large, compared t o the DCI-HC1 case, are linear with pressure

of broadener gas,

The results of our study would indicate that the shifts

and are opposite to the direction predicted by theory.

EXPERIMENTAL METHOD

The spectrometer, the cells, and the method of handling of the gases 4

used in this study are basically as reported for earlier studies.

ever, several modifications of the instrument have since been made. A

600-Hz chopper incorporating a tuned reference signal is used in conjun-

ction with a phase-sensitive Princeton Applied Research Amplifier, model

KR-8, and a Texas Instruments model FWS recorder. A Nernst-type filament

is used as the source and the detector is an uncooled lead sulphide photo

How-

conductor made to order by the

resolution of the spectrometer

mental slit half width of 0.14

Santa Barbara Research Corporation. The

may be estimated from the measured instru-

cm . The signal to noise ratio varied from

a -1

fifty to one to five to one.

Page 3: search.jsp?R=19710023696 2018-03 … · The cell-manifold pressure was then read on a Bourdon gauge. ... consider the sources of error in the experiment to ... all the possible precautions

-3 --

A two-cell method of measuring line shifts was employed to reduce

error due to instrumental drift. An elevator inside the vacuum housing

brought the reference cell and then the sample cell into the beam. By this

means the time between runs was considerably reduced from that of the single

ce l l method. The reduction in error in the measurement as compared to the

one-cell method is illustrated in Fig. 1 which compares the line shifts

measured by Herget, -- et a 1 7 in self-broadened HF (a one-cell method) with

those measured by the authors for the same gas. The shifts measured by the

authors are reported in Table I. The reference cell (17.8 cm) contained a

trace of HF. The pressures and lengths in the sample cell were 37.5 cm J3g

(17.8 cm), 76 cm Hg (1.62 cm), and 113.5 cm Hg (0.047 cm). Both cells were

held at room temperature, 24OC - + 2OC. The mean deviation calculated for

this study, 0.5 x 10’4cm-1/cm Hg, is about one third of that reported by

Herget. The agreement of the results of the two studies is quite good,

however . Gas, whether DF or HF, was admitted to the cell open to the manifold at

room temperature. The cell-manifold pressure was then read on a Bourdon

gauge. Subsequently, the cell was closed, heated to temperature, and a run

was made. The pressure of the gas at the higher temperatures was calculated

by the ideal gas approximation.

formation and non-ideality of the gases that this approximation would not be

good enough.

read the cell pressure directly.

It was feared that because of possible polymer

A check on these measurements was made by method devised to 6

A pressure transducer was mounted

Page 4: search.jsp?R=19710023696 2018-03 … · The cell-manifold pressure was then read on a Bourdon gauge. ... consider the sources of error in the experiment to ... all the possible precautions

-4-

in the cell body and calibrated in the desired pressure range.

transducer used was a type M6S, Model No. SA-SA manufactured by the Cornyel

Corporation.

The pressure

It is temperature-compensated from 23OC to 15OoC for the range

of pressure from 0 - 6 atm. It was read when the cell was at the proper

temperature and its reading checked against the ideal gas approximation.

The readings differed at most by 5 cm Hg at the highest pressure readings.

This difference led to a possible error in the line shift measurement of

about fifteen percent of the average shift observed.

RESULTS

Five sets of data were recorded for the line shifts in the first over-

tone of DF broadened by HF. The temperatures, cells and path lengths are

given in Table 11. The line shift per unit pressure is presented in Table

\ I11 for each line measured, The measured line shifts are plotted in Fig-

ures 2 and 3 as a function of the difference in pressure of the sample and

reference. It appears that with the exception of a few points there is good

evidence for the linearity of the shifts with pressure. It is also signifi- . .

cant that the straight lines which have been drawn as the lines of best fit

pass reasonably well through the origin. This result would indicate that

no large systematic error in pressure measurements exists.

The measured shifts as a function of J-number are displayed in Fig. 4.

The points plotted are the averages of the five sets of data taken. The

results of Jaffe, et al. for the DC1-HC1 system are also reproduced for

comparison.

can be seen from the graph that large amplitude oscillations occur in the

The average deviations are indicated by the error bars. It

R-branch and from P ( 3 ) outward in the P-branch. These oscillations are in

Page 5: search.jsp?R=19710023696 2018-03 … · The cell-manifold pressure was then read on a Bourdon gauge. ... consider the sources of error in the experiment to ... all the possible precautions

-5-

phase wi th those i n the DC1-HC1 system bu t are considerably l a r g e r i n amp-

l i t u d e . I n , t h e wings, e.g., f o r t h e R(6) l i n e t h e va lue of. t h e s h i f t i s

comparable t o t h e va lue found f o r HF s h i f t e d by Xenon.7

5.6 IZ

This va lue of

cm-l /cm Hg i s indica ted a t R(6) on t h e graph.

ERRORS

The e r r o r ba r s i n Fig. 4 represent t h e averaging of t h e s c a t t e r e d poin ts .

It is i l lumina t ing t o consider t h e sources of e r r o r i n the experiment t o see

how t h e estimated e r r o r compares with measured e r ro r .

e r r o r are i n t h e pressure measurement, i n instrumental d r i f t and i n de te r -

mination of l i n e peak.

The major sources of

Instrumental d r i f t w a s checked by running and rerunning a l i n e . For

example, f o r t h e R(1) l i n e the magnitude of t h e maximum frequency d i f f e rence

i n t h r e e runs w a s 0.002 cm which is about 0.4 of t h e minimum s h i f t observed. -1

The problems assoc ia ted with t h e measurement of l i n e cen te r s and gas im-

p u r i t y are r e l a t ed , Even a f t e r a l l t h e poss ib le precautions were taken i n

the handling of t h e DF, a considerable amount of DF, perhaps about 50 per-

cent of it, w a s converted i n t o HF.

problem.

This conversion c rea ted a two-fold

F i r s t , i t was no t poss ib l e t o know t h e exac t pressure of DF i n s i d e

t h e cell , and second i t required a considerably l a r g e r amount of gas i n s i d e

t h e r e fe rence cell . I f t h e gas were pure, a trace of DF would be s u f f i c i e n t

t o produce a sharp ly peaked line--at least near t h e band center . However,

i t w a s found t h a t t h e converted HF had a s t rong e f f e c t upon t h e peak he ights ,

tending sharp ly t o reduce t h e l i n e peak. It w a s t h i s e f f e c t t h a t prevented

us from studying t h e l i n e s beyond P ( 7 ) and R ( 6 ) and, moreover, l e d t o a

l a r g e r amount of DF being requi red t o obta in measurable i n t e n s i t i e s of t h e

l i n e s near t h e band center. A t t h e low pressures of DF a l i n e i n t h e wing

is very weakly absorbing. Amplification of t h e s i g n a l only increased t h e

Page 6: search.jsp?R=19710023696 2018-03 … · The cell-manifold pressure was then read on a Bourdon gauge. ... consider the sources of error in the experiment to ... all the possible precautions

-6-

noise level, making it difficult to find the line peak precisely. The

same line at a high pressure of DF is quite flat. The conversion of

DF to HF also prevented us from reporting on the line shifts of HF per-

trubed by DF. First, because it was not possible to take a trace of HF

and large amounts of DF, and second, because flattening of line peaks

also occurred.

scatters in the points are found for the lines further away from the band

center. Those lines were weakly absorbing and hence the peaks were not

sharply defined.

was rather natural.

drift and pressure measurements is about - + .9 cm-l/crn Hg x

scatter found is - i- .7 cm-'/cm Hg x 10' . of scatter was considerably less than the shift observed.

Along this line it is interesting to note that the most

In these cases a larger error in determining line peak

The mean error estimated by adding the errors due to

The mean

4 In all the cases the magnitude

A qualitative approach

molecular system is given by

action. Jaffe, et a1.l have

CONCLUSIONS

to the origin of the line shifting in this

the thoery of the near-resonant dipolar inter-

given the expression for the energy change due

t o the dipolar interaction as derived from second order perturbation theory.

When the molecular parameters for HF and DF are substituted into this ex-

pression, the calculated energy shifts are such as to lead to large oscil-

lating line shifts. However, just as in the DCl-HCl case, the predicted

shifts are exactly opposite to those observed. The shifts not only oscil-

late but increase in magnitude toward the red in the R-branch and the

blue in the P-branch.

Page 7: search.jsp?R=19710023696 2018-03 … · The cell-manifold pressure was then read on a Bourdon gauge. ... consider the sources of error in the experiment to ... all the possible precautions

-7-

1. The work was supported by the National Aeronautical ahd Space Admin-

istration, Grant NGL-43-001-006.

J.H. Jaffe, M.A. Hirshfeld and A . Ben-Reuven, J. Chem. Phys., L 40

1705 (1964).

2.

3. Private communication to the authors from Arieh Rosenberg, Institute of

Chemistry, Tel-Aviv University,

4. Herndon, J.A., W.E. Deeds, N.M. Gailar, W.F. Herget, R.J. Lovell and

A.H. N€elsen, J. Optical Society, - 52, 1108 (1962).

5 . Herndon, J.A., W.E. Deeds, N.M. Gailar, W.F. Herget, R.J; Lovell and

A.H. Nielsen, J. Optical Society, - 52, 113 (1962).

This direct-reading method was not available until near the end of this 6 .

study. The measurements could not be more extensively redone because of

time committments.for the spectrometer.

7. J.H. Jaffe, A. RosBnberg, M.A. Hirshfeld, and N.M. Gailar, J. Chem. Phys.,

- 43, 1525 (1965).

Page 8: search.jsp?R=19710023696 2018-03 … · The cell-manifold pressure was then read on a Bourdon gauge. ... consider the sources of error in the experiment to ... all the possible precautions

Table I

bbserved line shifts per unit pressure in HF

Line

. .

Line Shift per Unit Pressure*

+ 3.9 + . 91 f .53 - 3.24 - 3 .44 - 3.99 - 3.54 - 2.66 - 2.86 + 1.79 + . 91 - .66 - .36 + 1.47 f 1.15

*Averages of measurements at pressures of 37.5 cm Hg, 76 cm Hg, 'and 113.5 cm Hg

.

Page 9: search.jsp?R=19710023696 2018-03 … · The cell-manifold pressure was then read on a Bourdon gauge. ... consider the sources of error in the experiment to ... all the possible precautions

W H

Q) rl P d

m rl rl aJ 0

a c a m a k 3 rn rn a k n m a k 3 U nt k aJ

m

t U

m 0 ma3 b b rlrl

. .

(v d

\D m

ln o\

ln .

b 0 N U

.

V 0 2 0 rl rl

4-l rn k

m o ma3 b b rid

. e

m e W e .

0 'a3

ln

m (v

N VI

V 0 N rl

0

Page 10: search.jsp?R=19710023696 2018-03 … · The cell-manifold pressure was then read on a Bourdon gauge. ... consider the sources of error in the experiment to ... all the possible precautions

f

d a m x

8 b ' .

ca O h d l x " II a l a

f

8 L l d

0 u x

f

8 L l rl

N r l x

N d d m r l d N m c n o * o c o N m m m d m N c n N r l a m N O b N b d m m N m a m d u N a a . . . . . . . . . . . . . .

+ + + + I + I I I I I + I +

d ~ m m m d o o m c a m c o o d U b N d b m m N O N c o O l n a N l - d m u N m a m d m N * a . . . . . . . . . . . . . .

+ + + + I + I I I I I + I +

a a o m m ~ u o N r l o r l m m r l m N b o r l m N r l a m r l m c o m a r l N u w m a m d a m * a . . . . . . . . . . . . . . .

+ + + + l + l l l i I + l +

Page 11: search.jsp?R=19710023696 2018-03 … · The cell-manifold pressure was then read on a Bourdon gauge. ... consider the sources of error in the experiment to ... all the possible precautions

Figure Captions

1. Figure 1.

0 - Herget e t a l , 0 - Desai e t a l , - rev ised curve using

t h e r e s u l t s of both s tud ie s .

Line S h i f t s per u n i t p ressure i n t h e 1-0 band of HF.

2. Figure 2. Measured Line s h i f t s f o r t h e R-branch l i n e s .

3. Figure 3. Measured l i n e s h i f t s f o r t he P-branch l i n e s .

4. Figure 4. A comparison of t h e pressure-induced s h i f t s of l i n e s

i n t h e 2-0 bands of DF-HF and DC1-HC1. ----- DF-HF, - DC 1-HC 1,

_---- t hese l i n e s as they appear i n J a f f e e t a1.l

d i c a t e s t he va lue measured by J a f f e e t a14 f o r t h e s h i f t of R(6)

i n t h e 2-0 band of HF-Xe. .

The arrow f in-

Page 12: search.jsp?R=19710023696 2018-03 … · The cell-manifold pressure was then read on a Bourdon gauge. ... consider the sources of error in the experiment to ... all the possible precautions

-1 AV cm x,o-4- AP cmHg Line Shift, -

Error Bars T Desai et ai I

P Branch

3

-4

,-3 0

b -2

* -1

-2

- 3

t- t 4

R Branch

t + 6

Error Bars Herget et al

t 8 I t I I

'lo' '12' J

Page 13: search.jsp?R=19710023696 2018-03 … · The cell-manifold pressure was then read on a Bourdon gauge. ... consider the sources of error in the experiment to ... all the possible precautions

Line Shift, Av, crn-' x 'IOo2 !

I

Page 14: search.jsp?R=19710023696 2018-03 … · The cell-manifold pressure was then read on a Bourdon gauge. ... consider the sources of error in the experiment to ... all the possible precautions

. . . . . ~ .. - ..-

Line Shift, Av, ern% I d *

i

P 0

cn 0

03 0

75 0

A

N 0

Page 15: search.jsp?R=19710023696 2018-03 … · The cell-manifold pressure was then read on a Bourdon gauge. ... consider the sources of error in the experiment to ... all the possible precautions

!

K

I / I

t I