5
SAGILED E-PLUS RCM V1_EN 24/12/2015 SAGITARIO LIGHTING S.L.U. Pág 1 de 5 C/Marqués de Sentmenat, 22 08014 Barcelona Spain / Tel: +34934911000 / [email protected] / skype:sagitario_lighting2 / www.sagitariolighting.com Linear system, consisting of flexible printed circuit boards with highest intensity 60 LED/m SMD and widest beam angle. Additionally, the electronic circuit features different protective components, against reverse polarity, against voltage peaks and for the maintenance of the current supply through the circuit in case some anomaly occurred. Supplied cut to size (minimum piece of 116mm), inserted in a transparent polycarbonate tube with sealed at both ends and a side cable connection. Suitable for linear, curved or not, cove lightings and architectural lightings where a higher performance is required. Maximum length per unit 6 m until 8 m interconnected. TECHNICAL SPECIFICATIONS OF LUMINARY POWER SUPPLY 24V DC POWER FACTOR - CONSUMPTION 14W/m CLASS Class 3 BEAM ANGLE 120º L.O.R. 93% PERFORMANCE DATA COLOR TEMP. (ºK) – CRI* FLUX** EFFICIENCY 820 (2.000 ºK – CRI min. 80) 1060 lm/m (75,72 lm/W) 824 (2.400 ºK – CRI min. 80) 1228 lm/m (87,71 lm/W) 827 (2.700 ºK – CRI min. 80) 1395 lm/m (99,64 lm/W) 830 (3.000 ºK – CRI min. 80) 1786 lm/m (127,54 lm/W) 840 (4.000 ºK – CRI min. 80) 1953 lm/m (139,50 lm/W) 850 (5.000 ºK – CRI min. 80) 1953 lm/m (139,50 lm/W) INTEGRATED REGULATION - AVAILABLE REGULATION DMX – DALI – 1/10V (via optional controllers / interfaces) CONNECTION Cable H03VV-F 3x0,35mm 2 (Long. 1000 mm) THERMAL MANAGEMENT Passive MATERIALS Profile: Polycarbonate with UV protection End cap: Polycarbonate GENERAL DIMENSIONS 18,2 x 12,75 x Cut to size (Max. 6000mm) WEIGHT 100 g/m aprox. INSTALLATION Surface OPERATING TEMPERATURE -10 ºC / 50 ºC PROTECTION IP67 / IK7 SAGILED RCM E-PLUS

SAGILED E-PLUS RCM V1 EN - Sagitario Lighting · SAGILED E-PLUS RCM V1_EN 24/12/2015 SAGITARIO LIGHTING S.L.U. Pág C/Marqués de Sentmenat, 22 08014 Barcelona Spain / Tel: +34934911000

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SAGILED E-PLUS RCM V1 EN - Sagitario Lighting · SAGILED E-PLUS RCM V1_EN 24/12/2015 SAGITARIO LIGHTING S.L.U. Pág C/Marqués de Sentmenat, 22 08014 Barcelona Spain / Tel: +34934911000

SAGILED E-PLUS RCM V1_EN 24/12/2015

SAGITARIO LIGHTING S.L.U. Pág 1 de 5 C/Marqués de Sentmenat, 22 08014 Barcelona Spain / Tel: +34934911000 / [email protected] / skype:sagitario_lighting2 / www.sagitariolighting.com

Linear system, consisting of flexible printed circuit boards with highest intensity 60 LED/m SMD and widest beam angle. Additionally, the electronic circuit features different protective components, against reverse polarity, against voltage peaks and for the maintenance of the current supply through the circuit in case some anomaly occurred. Supplied cut to size (minimum piece of 116mm), inserted in a transparent polycarbonate tube with sealed at both ends and a side cable connection. Suitable for linear, curved or not, cove lightings and architectural lightings where a higher performance is required. Maximum length per unit 6 m until 8 m interconnected.

TECHNICAL SPECIFICATIONS OF LUMINARY

POWER SUPPLY 24V DC

POWER FACTOR -

CONSUMPTION 14W/m

CLASS

Class 3

BEAM ANGLE 120º

L.O.R. 93%

PERFORMANCE DATA

COLOR TEMP. (ºK) – CRI* FLUX** EFFICIENCY 820 (2.000 ºK – CRI min. 80) – 1060 lm/m (75,72 lm/W)

824 (2.400 ºK – CRI min. 80) – 1228 lm/m (87,71 lm/W)

827 (2.700 ºK – CRI min. 80) – 1395 lm/m (99,64 lm/W)

830 (3.000 ºK – CRI min. 80) – 1786 lm/m (127,54 lm/W)

840 (4.000 ºK – CRI min. 80) – 1953 lm/m (139,50 lm/W)

850 (5.000 ºK – CRI min. 80) – 1953 lm/m (139,50 lm/W)

INTEGRATED REGULATION

-

AVAILABLE REGULATION

DMX – DALI – 1/10V (via optional controllers / interfaces)

CONNECTION Cable H03VV-F 3x0,35mm2 (Long. 1000 mm)

THERMAL MANAGEMENT

Passive

MATERIALS Profile: Polycarbonate with UV protection End cap: Polycarbonate

GENERAL DIMENSIONS

18,2 x 12,75 x Cut to size (Max. 6000mm)

WEIGHT 100 g/m aprox.

INSTALLATION Surface

OPERATING TEMPERATURE

-10 ºC / 50 ºC

PROTECTION IP67 / IK7

SAGILED RCM E-PLUS

Page 2: SAGILED E-PLUS RCM V1 EN - Sagitario Lighting · SAGILED E-PLUS RCM V1_EN 24/12/2015 SAGITARIO LIGHTING S.L.U. Pág C/Marqués de Sentmenat, 22 08014 Barcelona Spain / Tel: +34934911000

SAGILED E-PLUS RCM V1_EN 24/12/2015

SAGITARIO LIGHTING S.L.U. Pág 2 de 5 C/Marqués de Sentmenat, 22 08014 Barcelona Spain / Tel: +34934911000 / [email protected] / skype:sagitario_lighting2 / www.sagitariolighting.com

LIFE TIME *** 50.000 h

TECHNICAL SPECIFICATIONS OF LAMP

LIGHT SOURCE LED SMD

Nº LEDs x mA ( Vf min.)

60 x 67mA (23V)

PERFORMANCE DATA

COLOR TEMP. (ºK) - CRI* FLUX** EFFICIENCY 820 (2.000 ºK – CRI min. 80) – 1140 lm/m (81,42 lm/W)

824 (2.400 ºK – CRI min. 80) – 1320 lm/m (94,28 lm/W)

827 (2.700 ºK – CRI min. 80) – 1500 lm/m (107,14 lm/W)

830 (3.000 ºK – CRI min. 80) – 1920 lm/m (137,14 lm/W)

840 (4.000 ºK – CRI min. 80) – 2100 lm/m (150,00 lm/W)

850 (5.000 ºK – CRI min. 80) – 2100 lm/m (150,00 lm/W)

* The temperature of colour and the wave length are approximated and can vary depending on the BIN of the LED.

** The luminous flux values are not indicated Typ. (25ºC). Correspond to values in temperature (85ºC). The light output may be subject to change by the constant evolution of LED technology and / or production circumstances.

*** Based on B10/L70 levels (test conducted in white LEDs).

ENERGY EFFICIENCY INDEX (IEE)

Page 3: SAGILED E-PLUS RCM V1 EN - Sagitario Lighting · SAGILED E-PLUS RCM V1_EN 24/12/2015 SAGITARIO LIGHTING S.L.U. Pág C/Marqués de Sentmenat, 22 08014 Barcelona Spain / Tel: +34934911000

SAGILED E-PLUS RCM V1_EN 24/12/2015

SAGITARIO LIGHTING S.L.U. Pág 3 de 5 C/Marqués de Sentmenat, 22 08014 Barcelona Spain / Tel: +34934911000 / [email protected] / skype:sagitario_lighting2 / www.sagitariolighting.com

PART NUMBER

SAG-RCM -E16 -C -24

REF. PRODUCT INTERDISTANCE CRI COLOR VOLTAGE

8 20

24

27

30

40

50

GENERAL DIMENSIONS

ACCESSORIES

REFERENCE DESCRIPTION DRAWING

SAG-FPC-E16-C-24 Sagiled Efficiency Plus 60LEDs/m

SAG-CDC-100 Ultra-adhesive double sided tape, to securely hold the Sagiled system.

SAG-MNG-303 Cable connection of 3x0,35mm² (Red, black, white)

SAG-TPC-1016/O Polycarbonate profile for Sagiled CM (Opal)

SAG-FBP-000 Surface fixing clip. Recommended 2 Uts. per meter. Minimum 2 uts. per luminaire.

SAG-FBP-060 Surface fixing clip 60º. Recommended 2 Uts. per meter. Minimum 2 uts. per luminaire.

Page 4: SAGILED E-PLUS RCM V1 EN - Sagitario Lighting · SAGILED E-PLUS RCM V1_EN 24/12/2015 SAGITARIO LIGHTING S.L.U. Pág C/Marqués de Sentmenat, 22 08014 Barcelona Spain / Tel: +34934911000

SAGILED E-PLUS RCM V1_EN 24/12/2015

SAGITARIO LIGHTING S.L.U. Pág 4 de 5 C/Marqués de Sentmenat, 22 08014 Barcelona Spain / Tel: +34934911000 / [email protected] / skype:sagitario_lighting2 / www.sagitariolighting.com

SAG-FBP-030 Surface fixing clip 30º. Recommended 2 Uts. per meter. Minimum 2 uts. per luminaire.

INSTALATIÓN

To clean up the insta llati on surfa ce wi thisopropyl alcohol to remove dirt and/or grease.

It is suggested to use a primer coating on 

surfaces with  an  energy below 38  mJ/m², as well as in slightly rough or painted surfaces.

It will not be necessary to use a primer coating over the following materials:Metals : luminium, anodized aluminium, A

stainless steel, copper, steel.Plastics:  PC, PMMA, PVC, PA, PS, ABSOther:  Glass

Recomendado 2 uds. por metro. Mínimo 2 uds. por luminaria.

Page 5: SAGILED E-PLUS RCM V1 EN - Sagitario Lighting · SAGILED E-PLUS RCM V1_EN 24/12/2015 SAGITARIO LIGHTING S.L.U. Pág C/Marqués de Sentmenat, 22 08014 Barcelona Spain / Tel: +34934911000

SAGILED E-PLUS RCM V1_EN 24/12/2015

SAGITARIO LIGHTING S.L.U. Pág 5 de 5 C/Marqués de Sentmenat, 22 08014 Barcelona Spain / Tel: +34934911000 / [email protected] / skype:sagitario_lighting2 / www.sagitariolighting.com

CONNECTION

COLOR DESCRIPTION NOTES

Red + 24V DC

Black - 24V DC Both joined to work without regulation.

White PWM

The fixture is supplied by default with the wires PWM and NEGATIVE separated, for dimming performance, thus expecting the wire PWM to be connected properly to the available interface (see table Page 1). For performing without dimming, join the wires PWM and NEGATIVE and connect them directly to the negative of the power supply equipment.

To interconnect several units the connection must be done in parallel.

Before running the wiring, check the connection specifications for equipment supply and / or control required by the technical documentation available.